Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deak, P. D., Smal, Y., & Kalender, W. A. (2010) · Radiology · doi:10.1148/radiol.10100047 · Cited by 858
Self-citationCT Dose Index and Patient Dose: They Are Not the Same Thing
McCollough, C. H., Leng, S., Yu, L., Cody, D. D., Boone, J. M., & McNitt-Gray, M. F. (2011) · Radiology · doi:10.1148/radiol.11101800 · Cited by 463
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Application‐ and patient size‐dependent optimization of x‐ray spectra for CT
Kalender, W. A., Deak, P., Kellermeier, M., van Straten, M., & Vollmar, S. V. (2009) · Medical Physics · doi:10.1118/1.3075901 · Cited by 206
Self-citationTechnical approaches to the optimisation of CT
Kalender, W. A., Buchenau, S., Deak, P., Kellermeier, M., Langner, O., van Straten, M., Vollmar, S., & Wilharm, S. (2008) · Physica Medica · doi:10.1016/j.ejmp.2008.01.012 · Cited by 199
Self-citationHow Effective Is Effective Dose as a Predictor of Radiation Risk?
McCollough, C. H., Christner, J. A., & Kofler, J. M. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.4179 · Cited by 169
“While some groups have performed Monte Carlo modeling of newer scanner models [32–40], these are evolving data sets and not yet widely available.”
BackgroundLell, M. M., May, M., Deak, P., Alibek, S., Kuefner, M., Kuettner, A., Köhler, H., Achenbach, S., Uder, M., & Radkow, T. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3181f33b1d · Cited by 166
“Details with respect to implementation and validation of the tool are reported elsewhere.(12) The tool allows dose calculations for arbitrary scanners and scan protocols.”
MethodSelf-citationFranck, C., Vandevoorde, C., Goethals, I., Smeets, P., Achten, E., Verstraete, K., Thierens, H., & Bacher, K. (2016) · European Radiology · doi:10.1007/s00330-015-4091-7 · Cited by 43
“The software calculates a 3D dose distribution in the patient-specific voxel model, considering all relevant photon interaction processes [20, 21].”
Method
Metadata
- Authors
- Deak, P., van Straten, M., Shrimpton, P. C., Zankl, M., & Kalender, W. A.
- Venue
- European Radiology
- Published
- 2007-12-08
- Volume
- 18
- Issue
- 4
- Pages
- 759-772
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2155375015
- Cited by
- 214
- References
- 0
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.