Computer-aided detection (CAD) of lung nodules in CT scans: radiologist performance and reading time with incremental CAD assistance
Open accessThe DOI matches its Crossref record.
Abstract
ObjectiveThe diagnostic performance of radiologists using incremental CAD assistance for lung nodule detection on CT and their temporal variation in performance during CAD evaluation was assessed.MethodsCAD was applied to 20 chest multidetector-row computed tomography (MDCT) scans containing 190 non-calcified ≥3-mm nodules. After free search, three radiologists independently evaluated a maximum of up to 50 CAD detections/patient. Multiple free-response ROC curves were generated for free search and successive CAD evaluation, by incrementally adding CAD detections one at a time to the radiologists’ performance.ResultsThe sensitivity for free search was 53% (range, 44%–59%) at 1.15 false positives (FP)/patient and increased with CAD to 69% (range, 59–82%) at 1.45 FP/patient. CAD evaluation initially resulted in a sharp rise in sensitivity of 14% with a minimal increase in FP over a time period of 100 s, followed by flattening of the sensitivity increase to only 2%. This transition resulted from a greater prevalence of true positive (TP) versus FP detections at early CAD evaluation and not by a temporal change in readers’ performance. The time spent for TP (9.5 s ± 4.5 s) and false negative (FN) (8.4 s ± 6.7 s) detections was similar; FP decisions took two- to three-times longer (14.4 s ± 8.7 s) than true negative (TN) decisions (4.7 s ± 1.3 s).ConclusionsWhen CAD output is ordered by CAD score, an initial period of rapid performance improvement slows significantly over time because of non-uniformity in the distribution of TP CAD output and not to a changing reader performance over time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Field, J. K., Duffy, S. W., Baldwin, D. R., Brain, K. E., Devaraj, A., Eisen, T., Green, B. A., Holemans, J. A., Kavanagh, T., Kerr, K. M., et al. (2016) · Health Technology Assessment · doi:10.3310/hta20400 · Cited by 296
Application of Artificial Intelligence in Lung Cancer
Chiu, H.-Y., Chao, H.-S., & Chen, Y.-M. (2022) · Cancers · doi:10.3390/cancers14061370 · Cited by 138
Artificial intelligence in thoracic surgery: a narrative review
Bellini, V., Valente, M., Del Rio, P., & Bignami, E. (2021) · Journal of Thoracic Disease · doi:10.21037/jtd-21-761 · Cited by 49
Li, D., Pehrson, L. M., Lauridsen, C. A., Tøttrup, L., Fraccaro, M., Elliott, D., Zając, H. D., Darkner, S., Carlsen, J. F., & Nielsen, M. B. (2021) · Diagnostics · doi:10.3390/diagnostics11122206 · Cited by 35
Kim, Y., Park, J. Y., Hwang, E. J., Lee, S. M., & Park, C. M. (2021) · Journal of Thoracic Disease · doi:10.21037/jtd-21-1342 · Cited by 31
“In terms of nodule detection, CAD models before the use of DL techniques showed insufficient performance to be implemented in clinical practice (85-87).”
Method
Metadata
- Authors
- Roos, J. E., Paik, D., Olsen, D., Liu, E. G., Chow, L. C., Leung, A. N., Mindelzun, R., Choudhury, K. R., Naidich, D. P., Napel, S., & Rubin, G. D.
- Venue
- European Radiology
- Published
- 2009-09-16
- Volume
- 20
- Issue
- 3
- Pages
- 549-557
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2061409412
- Cited by
- 79
- References
- 0
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computer-aided detection (CAD) of lung nodules in CT scans: radiologist performance and reading time with incremental CAD assistance. https://app.cochat.ai/papers/10.1007/s00330-009-1596-y
- The paper
- Roos, J. E., Paik, D., Olsen, D., Liu, E. G., Chow, L. C., Leung, A. N., Mindelzun, R., Choudhury, K. R., Naidich, D. P., Napel, S., & Rubin, G. D. (2010). Computer-aided detection (CAD) of lung nodules in CT scans: radiologist performance and reading time with incremental CAD assistance. European Radiology. https://doi.org/10.1007/s00330-009-1596-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.