Dixon-based MRI for assessment of muscle-fat content in phantoms, healthy volunteers and patients with achillodynia: comparison to visual assessment of calf muscle quality
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Objectives To quantify the muscle fat-content (MFC) in phantoms, volunteers and patients with achillodynia using two-point Dixon-based magnetic resonance imaging (2pt-MRIDIXON) in comparison to MR spectroscopy (MRS) and visual assessment of MFC.Methods Two-point Dixon-based MRI was used to measure the MFC of 15 phantoms containing 0-100 % fat-content and calf muscles in 30 patients (13 women; 57 ± 15 years) with achillodynia and in 20 volunteers (10 women; 30 ± 14 years) at 1.5 T. The accuracy of 2pt-MRIDIXON in quantification of MFC was assessed in vitro using phantoms and in vivo using MRS as the standard of reference. Fat-fractions derived from 2pt-MRIDIXON (FFDIXON) and MRS (FFMRS) were related to visual assessment of MFC (Goutallier grades 0-4) and Achilles-tendon quality (grade 0-4).Results Excellent linear correlation was demonstrated for FFDIXON with phantoms and with FFMRS in patients (p c = 0.997/0.995; p < 0.001). FFDIXON of the gastrocnemius muscle was significantly higher (p = 0.002) in patients (7.0 % ± 4.7 %) compared with volunteers (3.6 % ± 0.7 %), whereas visual-grading showed no difference between both groups (p > 0.05). FFMRS and FFDIXON were significantly higher in subjects with (>grade 1) structural damage of the Achilles-tendon (p = 0.01).Conclusions Two-point Dixon-based MRI allows for accurate quantification of MFC, outperforming visual assessment of calf muscle fat. Structural damage of the Achilles tendon is associated with a significantly higher MFC.Key points Two-point Dixon-based MRI allows accurate quantification of muscular fat content (MFC). Quantitative analysis outperforms visual analysis in the detection of elevated MFC. Achillodynia results in an increased MFC of the gastrocnemius muscles. Structural damage of the Achilles tendon further increases the MFC.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These aberrant changes can lead to reduced muscle mass and strength, both crucial components of sarcopenia.63–65”
From Imaging of Sarcopenia in Type 2 Diabetes Mellitus (2024) · cites this paper as [63]
Citations
Cites
Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan.
GOUTALLIER, D., Postel, J.-M., BERNAGEAU, J., Lavau, L., & Voisin, M. C. (1994) · PubMed · Cited by 2,554
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276 · cited 1×
“This algorithm was shown to provide stable water- and fat-signal separation for dual-echo imaging using phase information to resolve the ambiguity of fat and water signal in chemical-shift imaging [3, 13].”
MethodFatty Muscle Degeneration in Cuff Ruptures: Pre- and Postoperative Evaluation by CT Scan
Goutallier, D., Postel, J.-M., Bernageau, J., Lavau, L., & Voisin, M.-C. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199407000-00014 · Cited by 2,150 · cited 2×
“Several studies have suggested that assessment of MFC may serve as a biomarker for detection of muscular insufficiency and prediction of post-surgical outcome in degenerative musculoskeletal disease [2, 7, 9, 10, 16, 18].”
BackgroundTENDON INJURY AND TENDINOPATHY: HEALING AND REPAIR
SHARMA, P., & MAFFULLI, N. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200501000-00030 · Cited by 1,074 · cited 2×
“Concerning pathophysiology, a series of mechanisms reducing tissue perfusion and mechanical irritation lead to degeneration of the tendon [6].”
BackgroundGladstone, J. N., Bishop, J. Y., Lo, I. K. Y., & Flatow, E. L. (2007) · The American Journal of Sports Medicine · doi:10.1177/0363546506297539 · Cited by 967 · cited 1×
“Several studies have suggested that assessment of MFC may serve as a biomarker for detection of muscular insufficiency and prediction of post-surgical outcome in degenerative musculoskeletal disease [2, 7, 9, 10, 16, 18].”
BackgroundYu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694 · cited 1×
“show—similar to the ex vivo study—a measurement bias of 2pt-MRIDixon for very small and high FFDIXON, probably due to noise bias [3] and single-peak modelling of fat [28, 29] respectively, resulting in a slope of 0.”
ResultDixon techniques for water and fat imaging
Ma, J. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21492 · Cited by 610 · cited 4×
“However, comparable to another study using fat/liver phantoms there was an overestimation of very small fat contents (0-4 %), which might be caused by the magnitude calculation of water-/fat-only images (noise bias) [3] affecting fat estimates according to the previously described algorithm (Eq.”
BackgroundMethodResultInfluentialAbdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination
Rofsky, N. M., Lee, V. S., Laub, G., Pollack, M. A., Krinsky, G. A., Thomasson, D., Ambrosino, M. M., & Weinreb, J. C. (1999) · Radiology · doi:10.1148/radiology.212.3.r99se34876 · Cited by 538 · cited 1×
“Advantages over MRS include a fast and volumetric data acquisition with both visualisation of anatomical structures and quantification of MFC in an ROI [22].”
MethodRelaxation effects in the quantification of fat using gradient echo imaging
Bydder, M., Yokoo, T., Hamilton, G., Middleton, M. S., Chavez, A. D., Schwimmer, J. B., Lavine, J. E., & Sirlin, C. B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.08.012 · Cited by 394 · cited 1×
“show—similar to the ex vivo study—a measurement bias of 2pt-MRIDixon for very small and high FFDIXON, probably due to noise bias [3] and single-peak modelling of fat [28, 29] respectively, resulting in a slope of 0.”
ResultGerber, C., Schneeberger, A. G., Hoppeler, H., & Meyer, D. C. (2007) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2007.02.122 · Cited by 340 · cited 2×
“Several studies have suggested that assessment of MFC may serve as a biomarker for detection of muscular insufficiency and prediction of post-surgical outcome in degenerative musculoskeletal disease [2, 7, 9, 10, 16, 18].”
Background
Cited by
Imaging of sarcopenia: old evidence and new insights
Albano, D., Messina, C., Vitale, J., & Sconfienza, L. M. (2020) · European Radiology · doi:10.1007/s00330-019-06573-2 · Cited by 400
Sarcopenia: Current Concepts and Imaging Implications
Boutin, R. D., Yao, L., Canter, R. J., & Lenchik, L. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.15.14635 · Cited by 323
“For example, a 2-point Dixon-based technique has been used to quantify muscle-fat content in the leg of patients with achillodynia [84].”
MethodSarcopenia: how to measure, when and why
Tagliafico, A. S., Bignotti, B., Torri, L., & Rossi, F. (2022) · La radiologia medica · doi:10.1007/s11547-022-01450-3 · Cited by 268
“[54] For these advanced MRI applications, Dixon-based MRI sequences resulted to be more reliable and easier to be handled than spectroscopy Dixon [53].”
MethodApplication of ultrasound for muscle assessment in sarcopenia: towards standardized measurements
Perkisas, S., Baudry, S., Bauer, J., Beckwée, D., De Cock, A.-M., Hobbelen, H., Jager-Wittenaar, H., Kasiukiewicz, A., Landi, F., Marco, E., et al. (2018) · European Geriatric Medicine · doi:10.1007/s41999-018-0104-9 · Cited by 255
Martin, R. L., Chimenti, R., Cuddeford, T., Houck, J., Matheson, J. W., McDonough, C. M., Paulseth, S., Wukich, D. K., & Carcia, C. R. (2018) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2018.0302 · Cited by 255
Crawford, R. J., Filli, L., Elliott, J. M., Nanz, D., Fischer, M. A., Marcon, M., & Ulbrich, E. J. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4596 · Cited by 257
Self-citationSarcopenia: imaging assessment and clinical application
Chianca, V., Albano, D., Messina, C., Gitto, S., Ruffo, G., Guarino, S., Del Grande, F., & Sconfienza, L. M. (2021) · Abdominal Radiology · doi:10.1007/s00261-021-03294-3 · Cited by 206
Current Concepts Review Update: Insertional Achilles Tendinopathy
Chimenti, R. L., Cychosz, C. C., Hall, M. M., & Phisitkul, P. (2017) · Foot & Ankle International · doi:10.1177/1071100717723127 · Cited by 171
“For example, the reported percentage of asymptomatic tendons with signs of Achilles tendinopathy on imaging range from 0% to 35% and the percentage of symptomatic tendons without signs of Achilles tendinopathy range from 0% to 19%.(4,24,37,101,106,111)”
Quantitative imaging techniques for the assessment of osteoporosis and sarcopenia
Guerri, S., Mercatelli, D., Aparisi Gómez, M. P., Napoli, A., Battista, G., Guglielmi, G., & Bazzocchi, A. (2018) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2018.01.05 · Cited by 169
“Two-point Dixon-based technique and chemical shift-based water-fat separation are two quantitative MRI techniques that have been frequently applied to objectively measure muscle fat content (145-147).”
MethodGrimm, A., Meyer, H., Nickel, D. M., Nittka, M., Raithel, E., Chaudry, O., Friedberger, A., Uder, M., KEMMLER, W. K., Quick, H. H., et al. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.04.011 · Cited by 122
Sarcopenia: Diagnosis and Management, State of the Art and Contribution of Ultrasound
Giovannini, S., Brau, F., Forino, R., Berti, A., D’Ignazio, F., Loreti, C., Bellieni, A., D’Angelo, E., Caro, F. D., Biscotti, L., et al. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10235552 · Cited by 108
“MRI allows a quantitative and qualitative assessment of the muscle, detecting abnormalities such as fibrous or adipose infiltration [36].”
BackgroundFitzgerald, G., Turiel, G., Gorski, T., Soro-Arnáiz, I., Zhang, J., Casartelli, N. C., Masschelein, E., Maffiuletti, N. A., Sutter, R., Leunig, M., et al. (2023) · Communications Biology · doi:10.1038/s42003-023-04504-y · Cited by 94
Farrow, M., Biglands, J. D., Tanner, S. F., Clegg, A. P., Brown, L., Hensor, E. M. A., O’Connor, P., Emery, P., & Tan, A. L. (2020) · Aging Clinical and Experimental Research · doi:10.1007/s40520-020-01530-2 · Cited by 76
Matsumura, N., Oguro, S., Okuda, S., Jinzaki, M., Matsumoto, M., Nakamura, M., & Nagura, T. (2017) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2017.03.019 · Cited by 69
“Two-point Dixonbased MRI measurements have been reported to allow for accurate quantification of the muscle/fat fraction.(2,31)”
MethodPinel, S., Kelp, N., Bugeja, J. M., Bolsterlee, B., Hug, F., & Dick, T. J. M. (2021) · Experimental Gerontology · doi:10.1016/j.exger.2021.111594 · Cited by 67
“…from ultrasound images has not been demonstrated. mDixon provides an alternative imaging technique that can be used to quantify muscle-specific, whole-muscle fat fractions in vivo with both accuracy (Fischer et al., 2014; Noble et al., 2014b) and reliability (Ponrartana et al., 2014).”
Nozaki, T., Tasaki, A., Horiuchi, S., Osakabe, C., Ohde, S., Saida, Y., & Yoshioka, H. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.13518 · Cited by 64
Nozaki, T., Tasaki, A., Horiuchi, S., Ochi, J., Starkey, J., Hara, T., Saida, Y., & Yoshioka, H. (2016) · Radiology · doi:10.1148/radiol.2016151789 · Cited by 61
MR imaging of skeletal muscle signal alterations: Systematic approach to evaluation
Kumar, Y., Wadhwa, V., Phillips, L. T., Pezeshk, P., & Chhabra, A. B. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.02.007 · Cited by 54
Achilles insertional tendinopathy: state of the art
Maffulli, N., Saxena, A., Wagner, E., & Torre, G. (2018) · Journal of ISAKOS Joint Disorders & Orthopaedic Sports Medicine · doi:10.1136/jisakos-2017-000144 · Cited by 50
Zhang, Y., Zhou, Z., Wang, C., Cheng, X., Wang, L., Duanmu, Y., Zhang, C., Veronese, N., & Guglielmi, G. (2018) · Diagnostic and Interventional Radiology · doi:10.5152/dir.2018.17323 · Cited by 51
Agten, C. A., Rosskopf, A. B., Gerber, C., & Pfirrmann, C. W. A. (2015) · European Radiology · doi:10.1007/s00330-015-4144-y · Cited by 49
Self-citationMarcon, M., Ciritsis, B. D., Laux, C. J., Nanz, D., Nguyen‐Kim, T. D. L., Fischer, M. A., Andreisek, G., & Ulbrich, E. J. (2014) · European Radiology · doi:10.1007/s00330-014-3424-2 · Cited by 46
“weakness might also be due to increasing fat content (due to loss of muscular function [40] or muscle de-innervation [41]), which is not considered in CSA measurements.”
BackgroundMethodSelf-citationFarrow, M., Biglands, J. D., Tanner, S. F., Hensor, E. M. A., Buch, M. H., Emery, P., & Tan, A. L. (2020) · Rheumatology · doi:10.1093/rheumatology/keaa364 · Cited by 42
MRI‐Derived Biomarkers Related to Sarcopenia: A Systematic Review
Codari, M., Zanardo, M., di Sabato, M. E., Nocerino, E. A., Messina, C., Sconfienza, L. M., & Sardanelli, F. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26931 · Cited by 43
Marcon, M., Ciritsis, B. D., Laux, C. J., Nanz, D., Fischer, M. A., Andreisek, G., & Ulbrich, E. J. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24777 · Cited by 41
Self-citationRadiologic Definition of Sarcopenia in Chronic Liver Disease
Lee, C., Kang, B.-K., & Kim, M. (2021) · Life · doi:10.3390/life11020086 · Cited by 44
“Quantitative analysis using DIXONbased MRI showed an excellent correlation in MRS, which outperformed visual assessment in the detection of muscle fat content [55].”
MethodMarcon, M., Berger, N., Manoliu, A., Fischer, M. A., Nanz, D., Andreisek, G., & Ulbrich, E. J. (2016) · Skeletal Radiology · doi:10.1007/s00256-015-2325-z · Cited by 40
“[27], these FSF values correlate with a Goutallier grading of 1, which means no fatty infiltration, apart from some fatty streaks.”
BackgroundSelf-citationResearch progress on sarcopenia in the musculoskeletal system
Mao, X., Lv, K., Qi, W., Cheng, W., Li, T., Sun, Y., Jin, H., Pan, H., & Wang, D. (2025) · Bone Research · doi:10.1038/s41413-025-00455-8 · Cited by 37
“45,46 One of the key strengths of MRI is its ability to detect both compositional and structural changes in skeletal muscle associated with aging and disease progression, including decreased muscle contractility accompanied by increased intramuscular adipose (IMAT) and connective tissues (IMCT).”
Kälin, P. S., Crawford, R. J., Marcon, M., Manoliu, A., Bouaicha, S., Fischer, M. A., & Ulbrich, E. J. (2018) · Skeletal Radiology · doi:10.1007/s00256-018-2945-1 · Cited by 38
Self-citationMartel‐Duguech, L., Alonso‐Jiménez, A., Bascuñana, H., Díaz‐Manera, J., Llauger, J., Nuñez‐Peralta, C., Biagetti, B., Montesinos, P., Webb, S. M., & Valassi, E. (2020) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgz329 · Cited by 36
Santoro, S., Khalil, M., Abdallah, H., Farella, I., Noto, A., Dipalo, G. M., Villani, P., Bonfrate, L., Ciaula, A. D., & Portincasa, P. (2024) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2024.03.004 · Cited by 33
Niemeyer, F., Zanker, A., Jonas, R., Tao, Y., Galbusera, F., & Wilke, H. (2022) · European Spine Journal · doi:10.1007/s00586-022-07320-w · Cited by 34
“MRI is recently gaining a wide interest for the study of lumbar muscles since it allows measuring the muscle mass and the amount of fat infiltration inside the tissue, as well as additional information regarding muscular oedema, fibrous infiltration, fiber contractility, and elasticity [7, 8], without any exposure to…”
BackgroundNavigating the Intersection: Sarcopenia and Sarcopenic Obesity in Inflammatory Bowel Disease
Calvez, V., Becherucci, G., Covello, C., Piccirilli, G., Mignini, I., Esposto, G., Laterza, L., Ainora, M. E., Scaldaferri, F., Gasbarrini, A., et al. (2024) · Biomedicines · doi:10.3390/biomedicines12061218 · Cited by 33
Khanna, R., Saltzman, M. D., Elliott, J. M., Hoggarth, M. A., Marra, G. M., Omar, I. M., Parrish, T. B., & Seitz, A. L. (2019) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-019-2631-z · Cited by 26
“This sequence is a chemical-shift imaging application producing water- and fat-only images from dual echo acquisitions with precise accuracy for %fat quantification [18, 22, 23].”
BackgroundT1- and T2*-Mapping for Assessment of Tendon Tissue Biophysical Properties: A Phantom MRI Study
Bachmann, E., Rosskopf, A. B., Götschi, T., Klarhöfer, M., Deligianni, X., Hilbe, M., Pfirrmann, C. W. A., Snedeker, J. G., & Fischer, M. A. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000532 · Cited by 25
Self-citationJugé, L., Olsza, I., Knapman, F. L., Burke, P. G. R., Brown, E. C., Stumbles, E., de Frescheville, A. F. B., Gandevia, S. C., Eckert, D. J., Butler, J. E., et al. (2021) · SLEEP · doi:10.1093/sleep/zsab192 · Cited by 26
Advances in imaging for assessing the design and mechanics of skeletal muscle in vivo
Dick, T. J. M., & Hug, F. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111640 · Cited by 30
Multiorgan Imaging for Interorgan Crosstalk in Cardiometabolic Diseases
Devesa, A., Delgado, V., Valkovič, L., Lima, J. A. C., Nagel, E. C., Ibáñez, B., & Raman, B. (2025) · Circulation Research · doi:10.1161/circresaha.125.325517 · Cited by 21
Intramuscular fat in children with unilateral cerebral palsy
D’Souza, A., Bolsterlee, B., Lancaster, A., & Herbert, R. (2020) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2020.105183 · Cited by 20
Ruby, L. C., Kunut, A., Nakhostin, D., Huber, F. A., Finkenstaedt, T., Frauenfelder, T., Sanabria, S. J., & Rominger, M. B. (2020) · European Radiology · doi:10.1007/s00330-020-06885-8 · Cited by 20
Donners, R., Hirschmann, A. C., Gutzeit, A., & Harder, D. (2021) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2021.01.013 · Cited by 20
Nguyen, C., Guerini, H., Zauderer, J., Rören, A., Seror, P., & Lefèvre‐Colau, M. (2016) · Joint Bone Spine · doi:10.1016/j.jbspin.2015.11.013 · Cited by 19
Niklasson, E., Borga, M., Leinhard, O. D., Widholm, P., Andersson, D. P., Wiik, A., Holmberg, M., Brismar, T. B., Gustafsson, T. P., & Lundberg, T. R. (2022) · British Journal of Radiology · doi:10.1259/bjr.20211094 · Cited by 21
Ogawa, M., Hashimoto, Y., Mochizuki, Y., Inoguchi, T., Kouzuma, A., Deguchi, M., Saito, M., Homma, H., Kikuchi, N., & Okamoto, T. (2023) · Experimental Physiology · doi:10.1113/ep090655 · Cited by 21
“Fischer et al. (2014) reported that IMF content determined via the two-point Dixon method was closely related to the total IMCL and extramyocellular lipids (EMCL) detected by proton magnetic resonance spectroscopy ( 1 H-MRS) ( r = 0.918–0.990, P < 0.001) (Fischer et al., 2014).”
MethodInfluentialVitale, J. A., Sconfienza, L. M., & Galbusera, F. (2023) · European Spine Journal · doi:10.1007/s00586-023-07982-0 · Cited by 18
“Magnetic resonance imaging (MRI) is a valid technique for the assessment of lumbar muscles CSA and FI without exposing subjects to ionizing radiation [6].”
Lee, D., Hong, K.-T., Lee, W., Khil, E. K., Lee, G. Y., Choi, J.-A., & Song, Y. (2020) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-020-03400-4 · Cited by 18
Grimm, A., Nickel, M. D., Chaudry, O., Uder, M., Jakob, F., Kemmler, W., Quick, H. H., & Engelke, K. (2019) · European Journal of Radiology · doi:10.1016/j.ejrad.2019.03.019 · Cited by 16
Feuerriegel, G. C., Marcus, R. P., Sommer, S., Wieser, K., Bouaicha, S., & Sutter, R. (2023) · Investigative Radiology · doi:10.1097/rli.0000000000001024 · Cited by 16
Comparing intramuscular adipose tissue on T1-weighted and two-point Dixon images
Ogawa, M., Yoshiko, A., Tanaka, N., Koike, T., Oshida, Y., & Akima, H. (2020) · PLoS ONE · doi:10.1371/journal.pone.0231156 · Cited by 17
Docking, S., Hart, H. F., Rio, E., Hannington, M. C., Cook, J. L., & Culvenor, A. G. (2021) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2021.9970 · Cited by 18
Farrow, M., Grainger, A. J., Tan, A. L., Buch, M. H., Emery, P., Ridgway, J. P., Feiweier, T., Tanner, S. F., & Biglands, J. D. (2019) · British Journal of Radiology · doi:10.1259/bjr.20190143 · Cited by 14
Lee, S. K., Jung, J., Kang, Y. R., Yang, J. J., & Yang, J. J. (2019) · Skeletal Radiology · doi:10.1007/s00256-019-03270-5 · Cited by 19
Foulkes, S., Howden, E. J., Antill, Y. C., Loi, S., Salim, A., Haykowsky, M. J., Daly, R. M., Fraser, S. F., & Gerche, A. L. (2020) · BMC Cancer · doi:10.1186/s12885-020-07123-6 · Cited by 15
“6%) measurement of muscle-fat content [54, 55].”
Gerlach, D. A., Schopen, K., Linz, P. R., Johannes, B. W., Titze, J. M., Zange, J., & Rittweger, J. (2017) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3647-4 · Cited by 16
Paik, J. J., Christopher‐Stine, L., Boesen, M., Carrino, J. A., Eggleton, S. P., Denis, D., & Kubassova, O. (2025) · Frontiers in Immunology · doi:10.3389/fimmu.2025.1455867 · Cited by 12
Wang, L., Lu, S., Feng, J., Ma, K., Duan, F., Wang, R., Cheng, X., Liu, Y., Imai, Y., Chen, H., et al. (2025) · Calcified Tissue International · doi:10.1007/s00223-025-01447-w · Cited by 13
Achilles Tendon Xanthomas: Fat-Water Separation at Baseline and after Treatment
Griffith, J. F., Hu, M., Yeung, D. K. W., Guo, P., Lam, S. L., Xiao, F., Wang, D., & Tomlinson, B. (2017) · Radiology · doi:10.1148/radiol.2017161435 · Cited by 13
Imaging of Sarcopenia in Type 2 Diabetes Mellitus
Wang, D., Zhang, G., Yu, Y., & Zhang, Z. (2024) · Clinical Interventions in Aging · doi:10.2147/cia.s443572 · Cited by 11
Zahradnik, T. M., Cresswell, M., Squier, K., Waugh, C., Brunham, L. R., Screen, H. R. C., & Scott, A. (2021) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04494-0 · Cited by 12
Whiteside, L., McDaid, L., Hales, R. B., Rodgers, J., Dubec, M. J., Huddart, R. A., Choudhury, A., & Eccles, C. L. (2022) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2022.06.005 · Cited by 11
Diagnostic imaging of two related chronic diseases: Sarcopenia and Osteoporosis
Tegola, L. L., Mattera, M., Cornacchia, S., Cheng, X., & Guglielmi, G. (2018) · Journal of Frailty Sarcopenia and Falls · doi:10.22540/jfsf-03-138 · Cited by 12
Intramuscular Fat in the Medial Gastrocnemius Muscle of People Who Have Had a Stroke
D’Souza, A., Bolsterlee, B., & Herbert, R. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00613 · Cited by 12
“…in the resonant frequencies of protons in water and lipids to measure fat fractions in each voxel. mDixon scans can accurately (Kovanlikaya et al., 2005a; Fischer et al., 2014; Noble et al., 2014b) and reliably (Ponrartana et al., 2014) quantify muscle-specific, whole-muscle fat fractions in vivo.”
BackgroundMatsumura, N., Kiyota, Y., Suzuki, T., Iwamoto, T., Nozaki, T., Jinzaki, M., Nakamura, M., & Nagura, T. (2024) · JSES International · doi:10.1016/j.jseint.2023.12.005 · Cited by 10
“3,13,17,22 However, the natural progression of muscle degeneration has rarely been assessed, 1 and no study has quantitatively evaluated the entire rotator cuff muscles.”
BackgroundLesões do Aquiles – Parte 1: Tendinopatias
Mansur, N. S. B., da Fonseca, L. F., Matsunaga, F. T., Baumfeld, D. S., Nery, C. A. D. S., & Tamaoki, M. J. S. (2020) · Revista Brasileira de Ortopedia · doi:10.1055/s-0040-1702953 · Cited by 10
Reproducibility of manual segmentation in muscle imaging.
Muzic, S. I., Paoletti, M., Solazzo, F., Belatti, E., Vitale, R., Bergsland, N., Bastianello, S., & Pichiecchio, A. (2021) · PubMed Central · doi:10.36185/2532-1900-052 · Cited by 10
Radiological Quantification of Sarcopenic Obesity and its Role in Chronic Liver Disease Severity
Çimşit, C., Kurşun, M., Demircioğlu, Ö., Dilber, F., Demirtaş, C. Ö., & Ergenç, İ. (2023) · Academic Radiology · doi:10.1016/j.acra.2023.03.001 · Cited by 9
Imaging: seeing muscle in new ways
Schiffenbauer, A. I. (2014) · Current Opinion in Rheumatology · doi:10.1097/bor.0000000000000105 · Cited by 9
Functional Imaging in Musculoskeletal Disorders in Menopause
Filippi, L., Camedda, R., Frantellizzi, V., Urbano, N., VINCENTIS, G. D., & Schillaci, O. (2023) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2023.10.001 · Cited by 7
Sun, H. Y., Xu, M.-T., Wang, X., Wang, M.-H., Bao-heng, W., Wang, F., & Pan, S. (2018) · Chinese Medical Journal · doi:10.4103/0366-6999.230740 · Cited by 7
Anwander, H., Fuhrer, F., Diserens, G., Moor, B. K., Boesch, C., Vermathen, P., Valenzuela, W., & Zumstein, M. A. (2019) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-019-01246-7 · Cited by 6
“Its feasibility to analyze fat and water content in the muscle in humans has been shown in lumbar as well as in calf muscles [14, 15].”
BackgroundMa, J., Sahoo, S., Imrey, P. B., Jin, Y., Baker, A. R., Entezari, V., Ho, J., Schickendantz, M. S., Farrow, L. D., Serna, A., et al. (2022) · JSES International · doi:10.1016/j.jseint.2022.08.014 · Cited by 6
Comparison of different MRI-based unsupervised segmentation algorithms in predicting sarcopenia
Zuo, H., Wang, Q., Bi, G., Wang, Y., Yang, G., Zhang, C., Song, Y., Wu, Y., Gong, X., & Bi, Q. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111748 · Cited by 6
Weedall, A., Wilson, A. J., & Wayte, S. C. (2019) · British Journal of Radiology · doi:10.1259/bjr.20190300 · Cited by 6
Assessment of facial autologous fat grafts using Dixon magnetic resonance imaging
Liao, X., Wang, X., Xu, Z., Guo, S., Gu, C., Jin, Z., Su, T., Chen, Y., Xue, H., & Yang, M. (2022) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-570 · Cited by 6
Friedberger, A., Figueiredo, C. P., Grimm, A., d’Oliveira, I., Bäuerle, T., Rech, J., Kleyer, A., Simón, D., Uder, M., Schett, G. A., et al. (2020) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-020-03194-5 · Cited by 6
“The excellent precision of MR 2 pt-Dixon for fat quantification had been demonstrated earlier [24].”
MethodAccuracy of fat fraction estimation using Dixon: experimental phantom study
Panina, O. Y., Gromov, A. I., Akhmad, E. S., Petraikin, A. V., Bogachev, D. A., Семенов, Д. С., Vladzymyrskyy, A. V., & Vasilev, Y. A. (2022) · Medical Visualization · doi:10.24835/1607-0763-1160 · Cited by 5
Coats‐Thomas, M. S., Baillargeon, E. M., Ludvig, D., Marra, G. M., Perreault, E. J., & Seitz, A. L. (2022) · Clinical Orthopaedics and Related Research · doi:10.1097/corr.0000000000002253 · Cited by 5
“Sagittal oblique images were acquired with a 3D two-point Dixon fat-water imaging sequence to quantify intramuscular fat [13, 16, 36] using a 3T Siemens MR scanner (Prisma, Siemens) and a 16-channel phased array shoulder coil.”
MethodLesões do Aquiles – Parte 2: Rupturas
Mansur, N. S. B., da Fonseca, L. F., Matsunaga, F. T., Baumfeld, D. S., Nery, C. A. D. S., & Tamaoki, M. J. S. (2020) · Revista Brasileira de Ortopedia · doi:10.1055/s-0040-1702948 · Cited by 5
Lu, J., Wang, Y., Huang, H., Chen, Z., Wang, Y., Cui, Z., Huang, J., Liang, Y., Su, Z., Chen, J., et al. (2025) · European Spine Journal · doi:10.1007/s00586-025-09541-1 · Cited by 4
Zoller, S., Pawlus, K., Paverd, C., Frauenfelder, T., Huber, F. A., & Martin, A. (2025) · Diagnostics · doi:10.3390/diagnostics15243239 · Cited by 4
“Fat infiltration in the RF has been well documented, with MRI studies showing increased intramuscular fat in older adults and individuals with reduced physical activity [6,9,30].”
Oh, J., Yoo, H. J., Chae, H. D., Choi, J., & Hong, S. H. (2023) · British Journal of Radiology · doi:10.1259/bjr.20220817 · Cited by 4
Shan, C., Yu, J., Zhu, Y., Zhao, J., Wang, L., Li, Y.-S., Lin, S.-Y., Liu, W., Lü, Q., & Tao, T. (2025) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaf272 · Cited by 4
Gönül, Y., Yucel, O., Eroğlu, M., Şentürk, İ., Eroğlu, S., Dikici, Ö., Cartilli, O., & Ulasli, M. (2016) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2016.02.005 · Cited by 4
Development and evaluation of emulsified reference materials for magnetic resonance imaging
Lee, S., Hwangbo, S., Hong, C., Lee, C., & Cho, H.-M. (2024) · Metrologia · doi:10.1088/1681-7575/ad1f7f · Cited by 3
“There have been many attempts to manufacture water-fat phantoms using ex vivo samples (e.g. pork meat and fat) [16, 17].”
Trinh, L., Lind, E., Peterson, P., Svensson, J., Olsson, L. E., & Månsson, S. (2017) · Tomography · doi:10.18383/j.tom.2017.00011 · Cited by 3
Presence of adipose tissue along the posteromedial tibial border
Okunuki, T., Tanaka, H., Akuzawa, H., Yabiku, H., Maemichi, T., Matsumoto, M., Hoshiba, T., & Kumai, T. (2021) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-021-00408-0 · Cited by 3
“ambiguity in chemical-shift imaging [8, 22].”
BackgroundMethodAssessment of calf muscle constitution in chronic Achilles tendon disease using Dixon-based MRI
Goller, S. S., Kajdi, G. W., Wirth, S. H., Snedeker, J. G., & Sutter, R. (2024) · Skeletal Radiology · doi:10.1007/s00256-024-04845-7 · Cited by 3
“…with lower back pain [29], for assessing fatty degeneration of the gastrocnemius and tibialis anterior muscles in patients with achillodynia [30], or, recently, for Image A shows a case of left-sided MP ATP with spindle-shaped thickening of the AT at the level of the middle third of the…”
InfluentialDemirel, Ö. B., Kılıç, T., Çukur, T., & Sarıtaş, E. Ü. (2020) · Medical Physics · doi:10.1002/mp.14032 · Cited by 3
“A two-point Dixon method was used to obtain separate images of water and fat tissues from axial slices in the mid-upper arm region.(20,21) The imaging parameters were: TR = 5.”
MethodBeale, C. C., & Secrest, S. (2021) · Veterinary Radiology & Ultrasound · doi:10.1111/vru.13019 · Cited by 3
Mensch, A., Nägel, S., Zierz, S., Kraya, T., & Stoevesandt, D. (2022) · Klinische Neurophysiologie · doi:10.1055/a-1738-5356 · Cited by 2
Svensson, R. B., Agergaard, A., Sardella, T. C. P., Reichl, C., Hjortshoej, M. H., Bayer, M. L., Hoeffner, R., Couppé, C., Kjær, M., & Magnusson, S. P. (2024) · Photoacoustics · doi:10.1016/j.pacs.2024.100656 · Cited by 2
“Musculoskeletal tissue changes can be assessed by a multitude of modalities including ultrasound [5,18 – 20], near-infrared spectroscopy (NIRS) [21], laser Doppler flowmetry [22], MRI [7,23] Contents lists available at ScienceDirect Photoacoustics [24].”
Effects of an exercise program on calf muscle characteristics in patients with Achilles tendinopathy
Karapınar, M., Smitheman, H. P., Cone, S. G., & Silbernagel, K. G. (2025) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2025.09.013 · Cited by 2
Filli, L., Ulbrich, E. J., Guggenberger, R., Boss, A., Fischer, M. A., Grande, F. D., Maurer, B., & Andreisek, G. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.11.007 · Cited by 2
Self-citationOrtega, X., Araneda, D., Takeshi Asahi, K., Corral, G., Rojas, G., Suárez, B., & Claudia Castiglioni, T. (2016) · Revista de Fomento Social · doi:10.1016/j.rchira.2016.11.005 · Cited by 2
Simão, D. T., Heise, C. O., Rodrigues, J. C., Yamauti, L. S., Villegas, R., Cho, Á. B., & Mattar, R. (2024) · Microsurgery · doi:10.1002/micr.31152 · Cited by 1
“Several techniques have been described for evaluating muscles in cases of suspected peripheral nerve denervation or lesions using nuclear magnetic resonance (Fischer et al., 2014; Kamath et al., 2008; Matsumura et al., 2017; Smith et al., 2014).”
MethodVosoughi, A. R., Akbarzadeh, A., Brevis, S., & Yoosefinejad, A. K. (2024) · MUSCULOSKELETAL SURGERY · doi:10.1007/s12306-024-00857-7 · Cited by 1
“In chronic AT rupture with grade 2, 3, or 4 fatty degeneration of the soleus and gastrocnemius muscles without normal function, tendon transfers must be considered [5, 11].”
InfluentialZhao, Z., Smith, F. E., Dick, T. J. M., & Hodson-Tole, E. F. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1594557 · Cited by 2
Ortega, X., Corral, G., Rojas, G., Carrizo, J., Suárez, B., & Claudia Castiglioni, T. (2018) · Revista Médica Clínica Las Condes · doi:10.1016/j.rmclc.2018.10.001 · Cited by 1
Arbab, D., Bouillon, B., Lüring, C., Gutteck, N., Lipphaus, A., & Lichte, P. (2022) · Operative Orthopädie und Traumatologie · doi:10.1007/s00064-022-00793-4 · Cited by 1
Quality of skeletal muscles during allogeneic stem-cell transplantation: a pilot study
Maeda, Y., Takao, S., Morita, S., Kondo, S., Yamashita, M., Sumitani, R., Oura, M., Sogabe, K., Takahashi, M., Fujii, S., et al. (2024) · BMJ Supportive & Palliative Care · doi:10.1136/spcare-2024-005070 · Cited by 1
Metadata
- Authors
- Fischer, M. A., Pfirrmann, C. W. A., Espinosa, N., Raptis, D. A., & Buck, F. M.
- Affiliations
- Universitätsklinik Balgrist (CH)
- University Hospital Zurich (CH)
- Corresponding author
- Fischer, Michael. A.
- Venue
- European Radiology
- Published
- 2014-03-07
- Volume
- 24
- Issue
- 6
- Pages
- 1366-1375
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2128564886
- Cited by
- 112
- References
- 32
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 11 · 2023: 9 · 2022: 11 · 2021: 11 · 2020: 15 · 2019: 8 · 2018: 11 · 2017: 7 · 2016: 7 · 2015: 5 · 2014: 3
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- green
- www.zora.uzh.ch
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- European Radiology (publishedVersion)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, other-oa)
- reroDoc Digital Library (submittedVersion)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Keywords
- muscle fat content, achillodynia, Achilles tendon, gastrocnemius, fat fraction quantification, MR spectroscopy
- MeSH terms
- Achilles Tendon, Adipose Tissue, Adult, Aged, Aged, 80 and over, Female, Humans, Magnetic Resonance Imaging, Male, Middle Aged, Magnetic Resonance Spectroscopy, Muscle, Skeletal, Phantoms, Imaging, Adiposity, Tendinopathy, Healthy Volunteers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.