CoChat

Dixon-based MRI for assessment of muscle-fat content in phantoms, healthy volunteers and patients with achillodynia: comparison to visual assessment of calf muscle quality

Open access

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

Objectives To quantify the muscle fat-content (MFC) in phantoms, volunteers and patients with achillodynia using two-point Dixon-based magnetic resonance imaging (2pt-MRIDIXON) in comparison to MR spectroscopy (MRS) and visual assessment of MFC.Methods Two-point Dixon-based MRI was used to measure the MFC of 15 phantoms containing 0-100 % fat-content and calf muscles in 30 patients (13 women; 57 ± 15 years) with achillodynia and in 20 volunteers (10 women; 30 ± 14 years) at 1.5 T. The accuracy of 2pt-MRIDIXON in quantification of MFC was assessed in vitro using phantoms and in vivo using MRS as the standard of reference. Fat-fractions derived from 2pt-MRIDIXON (FFDIXON) and MRS (FFMRS) were related to visual assessment of MFC (Goutallier grades 0-4) and Achilles-tendon quality (grade 0-4).Results Excellent linear correlation was demonstrated for FFDIXON with phantoms and with FFMRS in patients (p c = 0.997/0.995; p < 0.001). FFDIXON of the gastrocnemius muscle was significantly higher (p = 0.002) in patients (7.0 % ± 4.7 %) compared with volunteers (3.6 % ± 0.7 %), whereas visual-grading showed no difference between both groups (p > 0.05). FFMRS and FFDIXON were significantly higher in subjects with (>grade 1) structural damage of the Achilles-tendon (p = 0.01).Conclusions Two-point Dixon-based MRI allows for accurate quantification of MFC, outperforming visual assessment of calf muscle fat. Structural damage of the Achilles tendon is associated with a significantly higher MFC.Key points Two-point Dixon-based MRI allows accurate quantification of muscular fat content (MFC). Quantitative analysis outperforms visual analysis in the detection of elevated MFC. Achillodynia results in an increased MFC of the gastrocnemius muscles. Structural damage of the Achilles tendon further increases the MFC.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00330-014-3121-1

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 113

Metadata

Authors
Fischer, M. A., Pfirrmann, C. W. A., Espinosa, N., Raptis, D. A., & Buck, F. M.
Affiliations
  • Universitätsklinik Balgrist (CH)
  • University Hospital Zurich (CH)
Corresponding author
Fischer, Michael. A.
Venue
European Radiology
Published
2014-03-07
Volume
24
Issue
6
Pages
1366-1375
ISSN
  • 0938-7994 (ISSN-L)
  • 1432-1084
OpenAlex
W2128564886
Cited by
112
References
32
Citations by year
2026: 4 · 2025: 10 · 2024: 11 · 2023: 9 · 2022: 11 · 2021: 11 · 2020: 15 · 2019: 8 · 2018: 11 · 2017: 7 · 2016: 7 · 2015: 5 · 2014: 3
FWCI
5.71
Type
journal article
Language
en
Open access
Licence
  • other-oa
  • www.springer.com/tdm (tdm)
Locations
  • European Radiology (publishedVersion)
  • PubMed (publishedVersion)
  • Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, other-oa)
  • reroDoc Digital Library (submittedVersion)
  • Zurich Open Repository and Archive (University of Zurich) (submittedVersion, other-oa)
  • Zurich Open Repository and Archive (University of Zurich)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
Keywords
muscle fat content, achillodynia, Achilles tendon, gastrocnemius, fat fraction quantification, MR spectroscopy
MeSH terms
Achilles Tendon, Adipose Tissue, Adult, Aged, Aged, 80 and over, Female, Humans, Magnetic Resonance Imaging, Male, Middle Aged, Magnetic Resonance Spectroscopy, Muscle, Skeletal, Phantoms, Imaging, Adiposity, Tendinopathy, Healthy Volunteers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.