Linear Paul trap design for an optical clock with Coulomb crystals
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
We report on the design of a segmented linear Paul trap for optical clock applications using trapped ion Coulomb crystals. For an optical clock with an improved short-term stability and a fractional frequency uncertainty of 10−18, we propose 115In+ ions sympathetically cooled by 172Yb+. We discuss the systematic frequency shifts of such a frequency standard. In particular, we elaborate on high-precision calculations of the electric radiofrequency field of the ion trap using the finite element method. These calculations are used to find a scalable design with minimized excess micromotion of the ions at a level at which the corresponding second-order Doppler shift contributes less than 10−18 to the relative uncertainty of the frequency standard.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Architecture for a large-scale ion-trap quantum computer
Kielpinski, D., Monroe, C., & Wineland, D. J. (2002) · Nature · doi:10.1038/nature00784 · Cited by 1,589
Experimental issues in coherent quantum-state manipulation of trapped atomic ions
Wineland, D. J., Monroe, C., Itano, W. M., Leibfried, D., King, B. E., & Meekhof, D. M. (1998) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.103.019 · Cited by 1,497
The Effect of Collisions upon the Doppler Width of Spectral Lines
Dicke, R. H. (1953) · Physical Review · doi:10.1103/physrev.89.472 · Cited by 1,491
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367
14-Qubit Entanglement: Creation and Coherence
Monz, T., Schindler, P., Barreiro, J. T., Chwalla, M., Nigg, D., Coish, W. A., Harlander, M., Hänsel, W., Hennrich, M., & Blatt, R. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.130506 · Cited by 1,110
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Resolved-Sideband Raman Cooling of a Bound Atom to the 3D Zero-Point Energy
Monroe, C., Meekhof, D. M., King, B. E., Jefferts, S. R., Itano, W. M., Wineland, D. J., & Gould, P. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.4011 · Cited by 731
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Spectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Ion-trap measurements of electric-field noise near surfaces
Brownnutt, M., Kumph, M., Rabl, P., & Blatt, R. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.1419 · Cited by 413
“Such plots have subsequently been widely invoked to claim that the experimental data show a d−4 scaling (e.g. Dubessy et al., 2009; Safavi-Naini et al., 2011; Herskind et al., 2011; Herschbach et al., 2012; Poulsen et al., 2012; Pyka et al., 2014).”
BackgroundHighly charged ions: Optical clocks and applications in fundamental physics
Kozlov, M. G., Safronova, M. S., Crespo López-Urrutia, J. R., & Schmidt, P. O. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.045005 · Cited by 311
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“In properly engineered linear traps (Herschbach et al., 2012; Pyka et al., 2014), the rf field exhibits a nodal line of vanishing electric field in axial direction which allows trapping of strings of ions as discussed in more detail in section 5.”
InfluentialSelf-citationTowards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
“In order not to perturb the ionic clock transition, only a single ion or a few ions can be interrogated in the field-free region of the trap even though attempts are made to enlarge the number of ions in multiple ion trap clocks [8].”
Background
Metadata
- Authors
- Herschbach, N., Pyka, K., Keller, J., & Mehlstäubler, T. E.
- Venue
- Applied Physics B
- Published
- 2011-11-16
- Volume
- 107
- Issue
- 4
- Pages
- 891-906
- ISSN
- 0721-7269 (ISSN-L)
- 0946-2171
- 1432-0649
- OpenAlex
- W2090494723
- Cited by
- 83
- References
- 12
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Linear Paul trap design for an optical clock with Coulomb crystals. https://app.cochat.ai/papers/10.1007/s00340-011-4790-y
- The paper
- Herschbach, N., Pyka, K., Keller, J., & Mehlstäubler, T. E. (2012). Linear Paul trap design for an optical clock with Coulomb crystals. Applied Physics B. https://doi.org/10.1007/s00340-011-4790-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.