The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared application to trace detection of hydrogen peroxide
Open accessAbstract
We demonstrate the first cavity-enhanced optical frequency comb spectroscopy in the mid-infrared wavelength region and report the sensitive real-time trace detection of hydrogen peroxide in the presence of a large amount of water. The experimental apparatus is based on a mid-infrared optical parametric oscillator synchronously pumped by a high-power Yb:fiber laser, a high-finesse broadband cavity, and a fast-scanning Fourier transform spectrometer with autobalancing detection. The comb spectrum with a bandwidth of 200 nm centered around 3.76 μm is simultaneously coupled to the cavity and both degrees of freedom of the comb, i.e. the repetition rate and carrier envelope offset frequency, are locked to the cavity to ensure stable transmission. The autobalancing detection scheme reduces the intensity noise by a factor of 300, and a sensitivity of 5.4×10−9 cm−1 Hz−1/2 with a resolution of 800 MHz is achieved (corresponding to 6.9×10−11 cm−1 Hz−1/2 per spectral element for 6000 resolved elements). This yields a noise equivalent detection limit for hydrogen peroxide of 8 parts-per-billion (ppb); in the presence of 2.8 % of water the detection limit is 130 ppb. Spectra of acetylene, methane, and nitrous oxide at atmospheric pressure are also presented, and a line-shape model is developed to simulate the experimental data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fourier Transform Infrared Spectrometry
Griffiths, P. R., & de Haseth, J. A. (2007) · doi:10.1002/047010631x · Cited by 3,052
Spectrometry with frequency combs
Schiller, S. (2002) · Optics Letters · doi:10.1364/ol.27.000766 · Cited by 445
Cited by
Schliesser, A., Picqué, N., & Hänsch, T. W. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.142 · Cited by 1,436
High-power sub-two-cycle mid-infrared pulses at 100 MHz repetition rate
Pupeza, I., Sánchez, D., Zhang, J., Lilienfein, N., Seidel, M., Karpowicz, N., Paasch-Colberg, T., Znakovskaya, I., Pescher, M., Schweinberger, W., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.179 · Cited by 304
Self-corrected chip-based dual-comb spectrometer
Hébert, N. B., Genest, J., Deschênes, J.-D., Bergeron, H., Chen, G. Y., Khurmi, C., & Lancaster, D. G. (2017) · Optics Express · doi:10.1364/oe.25.008168 · Cited by 122
Metadata
- Authors
- Foltynowicz, A., Masłowski, P., Fleisher, A. J., Bjork, B. J., & Ye, J.
- Venue
- Applied Physics B
- Published
- 2012-05-01
- Volume
- 110
- Issue
- 2
- Pages
- 163-175
- ISSN
- 0721-7269 (ISSN-L)
- 0946-2171
- 1432-0649
- OpenAlex
- W2098825766
- Cited by
- 168
- References
- 2
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared application to trace detection of hydrogen peroxide. https://app.cochat.ai/papers/10.1007/s00340-012-5024-7
- The paper
- Foltynowicz, A., Masłowski, P., Fleisher, A. J., Bjork, B. J., & Ye, J. (2013). Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared application to trace detection of hydrogen peroxide. Applied Physics B. https://doi.org/10.1007/s00340-012-5024-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.