A single-ion trap with minimized ion–environment interactions
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
AbstractWe present a new single-ion endcap trap for high-precision spectroscopy that has been designed to minimize ion–environment interactions. We describe the design in detail and then characterize the working trap using a single trapped $$^{171}{\rm Yb}^{+}$$171Yb+ ion. Excess micromotion has been eliminated to the resolution of the detection method, and the trap exhibits an anomalous phonon heating rate of $$d\langle n\rangle /{\mathrm{d}}t = 24 ^{+30}_{-24}\,{\rm s}^{-1}$$d⟨n⟩/dt=24-24+30s-1. The thermal properties of the trap structure have also been measured with an effective temperature rise at the ion’s position of $${\Delta }T_{\mathrm{(ion)}} = 0.14 \pm 0.14\,{\rm K}$$ΔT(ion)=0.14±0.14K. The small perturbations to the ion caused by this trap make it suitable to be used for an optical frequency standard with fractional uncertainties below the $$10^{-18}$$10-18 level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Quantum simulation of the Dirac equation
Gerritsma, R., Kirchmair, G., Zähringer, F., Solano, E., Blatt, R., & Roos, C. F. (2010) · Nature · doi:10.1038/nature08688 · Cited by 725
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationIon-trap measurements of electric-field noise near surfaces
Brownnutt, M., Kumph, M., Rabl, P., & Blatt, R. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.1419 · Cited by 413
Modular entanglement of atomic qubits using photons and phonons
Hucul, D., Inlek, I. V., Vittorini, G., Crocker, C., Debnath, S., Clark, S. M., & Monroe, C. (2015) · Nature Physics · doi:10.1038/nphys3150 · Cited by 311 · cited 1×
“Many uses for such traps have been found, from frequency metrology and tests of fundamental physics [1–3], to simulations of quantum systems [4, 5] and quantum information processing [6, 7]; however, the imperfections inherent with any physical”
BackgroundHite, D. A., Colombe, Y., Wilson, A. C., Brown, K. R., Warring, U., Jördens, R., Jost, J. D., McKay, K. S., Pappas, D. P., Leibfried, D., et al. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.103001 · Cited by 176
Cited by
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“Ion traps offer long storage times of hours to months, making them robust and reliable candidates for user-friendly clocks operating in the field (Nisbet-Jones et al., 2016).”
(2017) · doi:10.1103/physrevlett.118.053002 · Cited by 102
A compact, transportable single-ion optical clock with 7.8 × 10−17 systematic uncertainty
Cao, J., Zhang, P., Shang, J., Cui, K., Yuan, J., Chao, S., Wang, S., Shu, H., & Huang, X. (2017) · Applied Physics B · doi:10.1007/s00340-017-6671-5 · Cited by 101
Baynham, C. F. A., Godun, R. M., Jones, J. M., King, S. A., Nisbet-Jones, P. B. R., Baynes, F., Rolland, A., Baird, P. E. G., Bongs, K., Gill, P., et al. (2018) · Journal of Modern Optics · doi:10.1080/09500340.2017.1384514 · Cited by 32
Self-citation
Metadata
- Authors
- Nisbet-Jones, P. B. R., King, S. A., Jones, J. M., Godun, R. M., Baynham, C. F. A., Bongs, K., Doležal, M., Balling, P., & Gill, P.
- Venue
- Applied Physics B
- Published
- 2016-03
- Volume
- 122
- Issue
- 3
- ISSN
- 0721-7269 (ISSN-L)
- 0946-2171
- 1432-0649
- OpenAlex
- W1784176714
- Cited by
- 36
- References
- 6
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.