The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Absolute frequency measurement of the optical clock transition in with an uncertainty of using a frequency link to international atomic time
Open accessAbstract
The highly forbidden 2S1/2→2F7/2 electric octupole transition in 171Yb+ is a potential candidate for a redefinition of the SI second. We present a measurement of the absolute frequency of this optical transition, performed using a frequency link to International Atomic Time to provide traceability to the SI second. The 171Yb+ optical frequency standard was operated for 76% of a 25-day period, with the absolute frequency measured to be 642 121 496 772 645.14(26) Hz. The fractional uncertainty of 4.0×10-16 is comparable to that of the best previously reported measurement, which was made by a direct comparison to local caesium primary frequency standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationUltrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
High-Accuracy Optical Clock Based on the Octupole Transition inYb+171
Huntemann, N., Okhapkin, M., Lipphardt, B., Weyers, S., Tamm, C., & Peik, E. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.090801 · Cited by 241
Sub-Hertz Optical Frequency Comparisons between Two TrappedYb+171Ions
Schneider, T., Peik, E., & Tamm, C. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.230801 · Cited by 204
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Research works printed but not linked: 1
- Denker, H.; Timmen, L.;Voigt, C.;Weyers, S.;Peik, E.;Margolis, H.S.;Delva, P.;Wolf, P.;Petit, G. Submitted to Journal of Geodesy (2017).
Cited by
Improved Limits for Violations of Local Position Invariance from Atomic Clock Comparisons
Lange, R., Huntemann, N., Rahm, J. M., Sanner, C., Shao, H., Lipphardt, B., Tamm, C., Weyers, S., & Peik, E. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.011102 · Cited by 200
Intercontinental comparison of optical atomic clocks through very long baseline interferometry
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., et al. (2021) · Nature Physics · doi:10.1038/s41567-020-01038-6 · Cited by 64
Pizzocaro, M., Bregolin, F., Barbieri, P., Rauf, B., Levi, F., & Calonico, D. (2020) · Metrologia · doi:10.1088/1681-7575/ab50e8 · Cited by 63
Analysis of atomic-clock data to constrain variations of fundamental constants
Sherrill, N., Parsons, A. O., Baynham, C. F. A., Bowden, W., Curtis, E. A., Hendricks, R., Hill, I. R., Hobson, R., Margolis, H. S., Robertson, B., et al. (2023) · New Journal of Physics · doi:10.1088/1367-2630/aceff6 · Cited by 96
Self-citationGeopotential measurement with a robust, transportable Ca+ optical clock
Huang, Y., Zhang, H., Zhang, B., Hao, Y., Guan, H., Zeng, M., Chen, Q., Lin, Y., Wang, Y., Cao, S., et al. (2020) · Physical Review A · doi:10.1103/physreva.102.050802 · Cited by 52
Metadata
- Authors
- Baynham, C. F. A., Godun, R. M., Jones, J. M., King, S. A., Nisbet-Jones, P. B. R., Baynes, F., Rolland, A., Baird, P. E. G., Bongs, K., Gill, P., & Margolis, H. S.
- Affiliations
- National Physical Laboratory (GB)
- University of Oxford (GB)
- University of Birmingham (GB)
- Corresponding author
- Godun, Rachel M.
- Venue
- Journal of Modern Optics
- Publisher
- Informa UK Limited
- Published
- 2017-10-06
- Volume
- 65
- Issue
- 5-6
- Pages
- 585-591
- ISSN
- 0950-0340 (ISSN-L)
- 1362-3044
- OpenAlex
- W2728318801
- Cited by
- 32
- References
- 31
- Citations by year
- 2025: 4 · 2024: 4 · 2023: 6 · 2022: 2 · 2021: 4 · 2020: 7 · 2019: 2 · 2018: 3
- FWCI
- 1.61
- Type
- journal article
- Language
- en
- Update notices
- correction (2018-01-24)
- Open access
- green
- arxiv.org
- Locations
- Journal of Modern Optics (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- arXiv (Cornell University)
- Funders
- European Metrology Research Programme (SIB55-ITOC)
- Department for Business, Energy and Industrial Strategy (National Measurement System Programme)
- UK Department for Business, Energy and Industrial Strategy
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- 171Yb, optical clock transition, electric octupole transition, absolute frequency measurement, frequency standards, Yb3+, traceability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Absolute frequency measurement of the optical clock transition in with an uncertainty of using a frequency link to international atomic time. https://app.cochat.ai/papers/10.1080/09500340.2017.1384514
- The paper
- Baynham, C. F. A., Godun, R. M., Jones, J. M., King, S. A., Nisbet-Jones, P. B. R., Baynes, F., Rolland, A., Baird, P. E. G., Bongs, K., Gill, P., & Margolis, H. S. (2018). Absolute frequency measurement of the optical clock transition in with an uncertainty of using a frequency link to international atomic time. Journal of Modern Optics. https://doi.org/10.1080/09500340.2017.1384514
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.