The effects of low-intensity pulsed ultrasound and pulsed electromagnetic fields bone growth stimulation in acute fractures: a systematic review and meta-analysis of randomized controlled trials
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Introduction The aim of this systematic review and meta-analysis was to evaluate the best currently available evidence from randomized controlled trials comparing pulsed electromagnetic fields (PEMF) or low-intensity pulsed ultrasound (LIPUS) bone growth stimulation with placebo for acute fractures.Materials and methods We performed a systematic literature search of the medical literature from 1980 to 2013 for randomized clinical trials concerning acute fractures in adults treated with PEMF or LIPUS. Two reviewers independently determined the strength of the included studies by assessing the risk of bias according to the criteria in the Cochrane Handbook for Systematic Reviews of Interventions.Results Seven hundred and thirty-seven patients from 13 trials were included. Pooled results from 13 trials reporting proportion of nonunion showed no significant difference between PEMF or LIPUS and control. With regard to time to radiological union, we found heterogeneous results that significantly favoured PEMF or LIPUS bone growth stimulation only in non-operatively treated fractures or fractures of the upper limb. Furthermore, we found significant results that suggest that the use of PEMF or LIPUS in acute diaphyseal fractures may accelerate the time to clinical union.Conclusions Current evidence from randomized trials is insufficient to conclude a benefit of PEMF or LIPUS bone growth stimulation in reducing the incidence of nonunions when used for treatment in acute fractures. However, our systematic review and meta-analysis suggest that PEMF or LIPUS can be beneficial in the treatment of acute fractures regarding time to radiological and clinical union. PEMF and LIPUS significantly shorten time to radiological union for acute fractures undergoing non-operative treatment and acute fractures of the upper limb. Furthermore, PEMF or LIPUS bone growth stimulation accelerates the time to clinical union for acute diaphyseal fractures.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In 2014, another systematic review and meta−analysis of randomized controlled trials came to a similar conclusion, reporting that the effect of LIPUS on bone growth stimulation could only be found in patients with nonoperatively treated fractures or fractures of the upper limb (20).”
From Methods to accelerate fracture healing – a narrative review from a clinical perspective (2024) · cites this paper as [20]
In the citing paper
“The same study revealed that the use of LIPUS for the treatment of diaphyseal fractures accelerated the time to clinical union.”
From Methods to accelerate fracture healing – a narrative review from a clinical perspective (2024) · cites this paper as [20]
In the citing paper
“According to a systematic review and meta−analysis of randomized controlled trials, PEMF significantly shortened the time to radiological union for acute fractures treated without surgery and for acute fractures of the upper limb (20).”
From Methods to accelerate fracture healing – a narrative review from a clinical perspective (2024) · cites this paper as [20]
In the citing paper
“Systematic reviews and meta-analyses concluded that low−intensity pulsed ultrasound (LIPUS) and pulsed electromagnetic fields (PEMFs) may accelerate the time to clinical union (20).”
From Methods to accelerate fracture healing – a narrative review from a clinical perspective (2024) · cites this paper as [20]
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
Assessing Risk of Bias in Included Studies
Higgins, J. P., & Altman, D. G. (2008) · Cochrane Handbook for Systematic Reviews of Interventions · doi:10.1002/9780470712184.ch8 · Cited by 3,396 · cited 1×
“Two reviewers (PFWH and JPmS) independently assessed the risk of bias in the included studies according to the methods in the Cochrane Handbook for Systematic reviews of Interventions [6].”
MethodAcceleration of tibial fracture-healing by non-invasive, low-intensity pulsed ultrasound.
Heckman, J. D., Ryaby, J. P., McCabe, J., Frey, J. J., & Kilcoyne, R. F. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199401000-00004 · Cited by 956
KRISTIANSEN, T. K., RYABY, J. P., McCABE, J., FREY, J. J., & ROE, L. R. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199707000-00002 · Cited by 586 · cited 6×
“After dividing the studies into two groups, diaphyseal fractures [9, 11, 13] and metaphyseal fractures [10, 12, 15, 16, 21], we found no significant differences in time to radiological union between PemF or LIPuS and placebo regarding diaphyseal (mD = −29.”
BackgroundInfluentialVariability in the Assessment of Fracture-Healing in Orthopaedic Trauma Studies
Corrales, L. A., Morshed, S., Bhandari, M., & Miclau, T. (2008) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.g.01580 · Cited by 415 · cited 1×
“Although union is a continuous process of bone reconstruction and there is no commonly accepted cut-off point for union of fractures, a valid and uniform measuring method to define radiological union for various fractures should be considered in future trials [31, 32].”
Azuma, Y., Ito, M., Harada, Y., Takagi, H., Ohta, T., & Jingushi, S. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.4.671 · Cited by 369 · cited 1×
“After adjustment of the signal intensity, results from several trials reporting faster callus formation in fractures caused international interest in the use of low-intensity pulsed ultrasound (LIPuS) as a potential method to accelerate bone healing [23, 24].”
BackgroundTreatment of ununited tibial diaphyseal fractures with pulsing electromagnetic fields.
Bassett, C. A., Mitchell, S. N., & Gaston, S. R. (1981) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198163040-00001 · Cited by 349
Cited by
Items 101–150 of 150
Carbone, I. F., Gigli, F. M. P., Rossi, G., Romagnoli, V., Gallicola, B., Sandi, F., Esposito, G., & Ferrazzi, E. M. (2024) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-024-07671-3 · Cited by 3
Physical Analysis of Pulse Low-Dynamic Magnetic Field Applied in Physiotherapy
Richter, A., Bartoš, M., & Ferková, Ž. (2018) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-9023-3_43 · Cited by 3
Patel, V. V., Billys, J. B., Okonkwo, D. O., He, D. Y., Ryaby, J. T., & Radcliff, K. E. (2021) · The International Journal of Spine Surgery · doi:10.14444/8031 · Cited by 3
ADVANCED NANOMATERIALS AND COATED SURFACES FOR ORTHOPEDIC IMPLANTS – A REVIEW
Balint, R., Mocanu, A., Tomoaia, G., Riga, S., & Tomoaia-Cotişel, M. (2021) · Annals of the Academy of Romanian Scientists Series on Physics and Chemistry · doi:10.56082/annalsarsciphyschem.2021.2.53 · Cited by 3
Fernández‐Cuadros, M. E., Pérez-Moro, O. S., Albaladejo-Florín, M. J., Ramos-González, C., Cabrera-Rodríguez, L., & Algarra-López, R. (2018) · Middle East Journal of Rehabilitation and Health Studies · doi:10.5812/mejrh.63850 · Cited by 3
“To the best of our knowledge, there are scarce studies on the effectiveness of PEFM in scaphoid fractures and the results are very limited and even controversial (7).”
BackgroundHiyama, S., Matsumura, T., Takahashi, T., Ae, R., & Takeshita, K. (2021) · Journal of Orthopaedic Science · doi:10.1016/j.jos.2021.09.001 · Cited by 3
Modern Physical Methods of Stimulating the Bone Tissue Healing Processes
Vares, Y. E., & Shtybel, N. V. (2019) · Ukraïnsʹkij žurnal medicini bìologìï ta sportu · doi:10.26693/jmbs04.06.009 · Cited by 3
PHYSICAL MODALITIES IN GERIATRIC PHYSICAL MEDICINE AND REHABILITATION
Benlidayı, İ. C., & Karaagac, H. (2025) · Anti-Aging Eastern Europe · doi:10.56543/aaeeu.2025.4.2.03 · Cited by 2
Xue, X., Lin, X., Gao, A., Cui, G., Liu, Q., Xu, B., & Song, Q. (2026) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1002/arj.70060 · Cited by 3
Walewicz, K., Halski, T., Dymarek, R., & Taradaj, J. (2023) · Physiotherapy Review · doi:10.5114/phr.2023.133715 · Cited by 2
Merali, F., & Leung, M. (2017) · PubMed Central · Cited by 2
Clinical Applications of Biophysical Stimuli Technologies for Bone Healing
Gebreyesus, E. A., Moorjani, A., Guldberg, R. E., & Ong, K. G. (2026) · Annals of Biomedical Engineering · doi:10.1007/s10439-026-04075-z · Cited by 2
Choo, S. K., Kim, Y., Shin, M. J., & Oh, H. K. (2015) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-015-2210-1 · Cited by 1
The role of biophysical enhancement (LIPUS, ESWT and PEMF’s) in fracture healing
Aifantis, I. D., & Mitsikostas, P. K. (2021) · Journal of Research and Practice on the Musculoskeletal System · doi:10.22540/jrpms-05-110 · Cited by 1
Iwaki, T., Sawaji, Y., Masaoka, T., Fukada, E., Date, M., & Yamamoto, K. (2024) · Bioelectromagnetics · doi:10.1002/bem.22501 · Cited by 1
“Both PEMF and LIPUS were found to be clinically effective for improving delayed unions and non ‐ unions and accelerating the treatment period after fresh fractures (Hannemann et al., 2014).”
BackgroundLü, Z., Gu, H.-Y., Li, Z., & Lin, F.-X. (2024) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2024.12736 · Cited by 1
“Low‑frequency‑pulsed electromagnetic field (LPEMF) is a noninvasive and inexpensive method that has shown effi‑ cacy against a wide range of diseases of the skeletal muscle system (3,4).”
MethodEngineering Niches for Bone Tissue Regeneration
Malhotra, A., van Blitterswijk, C., & Habibović, P. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-802734-9.00031-7 · Cited by 1
Role of Adenosine Receptors in Clinical Biophysics Based on Pulsed Electromagnetic Fields
Varani, K., Vincenzi, F., Cadossi, M., Setti, S., Borea, P. A., & Cadossi, R. (2018) · Springer eBooks · doi:10.1007/978-3-319-90808-3_24 · Cited by 1
Evaluating the Effectiveness of Biophysical Methods of Osteogenesis Stimulation: Review
Emelianov, V. U., Преображенская, Е. В., & Николаев, Н. С. (2021) · Traumatology and Orthopedics of Russia · doi:10.21823/2311-2905-2021-27-1-86-96 · Cited by 1
Reilingh, M. L., van Bergen, C. J. A., Gerards, R. M., van Eekeren, I. C. M., de Haan, R. J., Sierevelt, I. N., Kerkhoffs, G. M. M. J., Krips, R., Meuffels, D. E., van Dijk, C. N., et al. (2016) · The American Journal of Sports Medicine · doi:10.1177/0363546516676454 · Cited by 1
Cadossi, M., Sambri, A., Sandro, G., & Massari, L. (2016) · The American Journal of Sports Medicine · doi:10.1177/0363546516676453 · Cited by 1
“However, defect location was not included in our stratification factors because defect location is not associated with clinical and radiological outcomes.(3,6) Cadossi et al write, ‘‘In the Methods section, the authors reported that a clock inside the device was used to monitor the hours of stimulation.”
BackgroundClinical evaluation of pulsed electromagnetic field treatment for acute scaphoid fractures
Hannemann, P. F. W. (2015) · Nederlands Tijdschrift voor Traumachirurgie · doi:10.1007/s12506-015-0019-8
Self-citationMethods to Enhance Bone Formation in Distraction Osteogenesis
Song, H., Lee, D. H., Kim, S. J., & Ramanathan, A. K. (2015) · Springer eBooks · doi:10.1007/978-3-319-17097-8_28
Sprague, S., & Goldberg, M. E. (2017) · doi:10.1002/9781119389668.ch16
Value of Pulsed Electromagnetic Stimulation in Acute Scaphoid Fractures
Hannemann, P. F. W., Poeze, M., & Brink, P. R. G. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-48564-7.00023-x
Self-citationShckorbatov, Y. (2018) · International Conference on Ultrawideband and Ultrashort Impulse Signals · doi:10.1109/uwbusis.2018.8520259
“Pulsed electric fields are used for stimulation of regeneration processes in the case of fractures of bones [2].”
BackgroundButezloff, M. M. (2019) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.17.2019.tde-27052019-145603 · Cited by 1
ICR-Like and Osteoarthritis in Geriatric Patients: Pilot Study at an RCH Facility
Alessandro, G. (2018) · Journal of Orthopedics and Rheumatism · doi:10.36959/479/429
Engineering advances in promoting bone union
Hughes, L., Aljawadi, A., & Charalambous, C. P. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819712-7.00002-4
PHYSICAL THERAPY IN BONE FRACTURES - FACTS AND MYTHS
Hejdysz, K., Sip, P., & Jastrzębska, P. (2017) · Issues of Rehabilitation Orthopaedics Neurophysiology and Sport Promotion – IRONS · doi:10.19271/irons-00041-2017-20
Mommers, E. H. H. (2018) · Research Publications (Maastricht University) · doi:10.26481/dis.20180329em
Self-citationWisneski, L., Gurfein, B., Barsotti, T., Chevalier, G., Mills, P. J., & Muehsam, D. J. (2017) · Routledge eBooks · doi:10.1201/9781315153889-9 · Cited by 1
What’s New in Musculoskeletal Basic Science
Allen, M. J. (2018) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.18.01055
Clinical evaluation of pulsed electromagnetic field treatment for acute scaphoid fractures
Hannemann, P. F. W. (2015) · Research Publications (Maastricht University) · doi:10.26481/dis.20150522ph
Self-citationHooper, R. C., Zeng, Y., Wang, L., & Chung, K. C. (2023) · Plastic & Reconstructive Surgery Global Open · doi:10.1097/gox.0000000000004782
Sun, L., Guo, X., Wang, Q., Shang, Z., Du, Y., & Song, G. (2023) · Acta Cirúrgica Brasileira · doi:10.1590/acbe380023
Methods to Enhance Bone Formation in Distraction Osteogenesis
Song, H., Lee, D., Park, Y. H., & Ramanathan, A. K. (2024) · Springer eBooks · doi:10.1007/978-3-031-55767-5_35
Li, Z., Zhou, Z., Chen, H., Xiao, M., Yin, Y., Zhao, L., Dai, Y., & Tang, Y. (2025) · Sexual Medicine Reviews · doi:10.1093/sxmrev/qeaf044
Kuroda, R., Niikura, T., Matsumoto, T., Fukui, T., Oe, K., Mifune, Y., Minami, H., Matsuoka, H., Yakushijin, K., Miyata, Y., et al. (2023) · Figshare · doi:10.6084/m9.figshare.24257517
Kuroda, R., Niikura, T., Matsumoto, T., Fukui, T., Oe, K., Mifune, Y., Minami, H., Matsuoka, H., Yakushijin, K., Miyata, Y., et al. (2024) · Figshare · doi:10.6084/m9.figshare.24257633
Darwiche, S., Kaczmarek, A., Schwarzenberg, P., Inglis, B. J., Lechmann, B., Kronen, P., Ferguson, S. J., Dailey, H. L., von Rechenberg, B., & Klein, K. (2024) · Figshare · doi:10.6084/m9.figshare.26599513
Chen, G., Zhuo, Y., Tao, B., Liu, Q., Shang, W., Li, Y., Wang, Y., Li, Y., Zhang, L., Fang, Y., et al. (2020) · Figshare · doi:10.6084/m9.figshare.13245611
Chen, G., Zhuo, Y., Tao, B., Liu, Q., Shang, W., Li, Y., Wang, Y., Li, Y., Zhang, L., Fang, Y., et al. (2020) · Figshare · doi:10.6084/m9.figshare.13245608
Xu, S., Li, R., Wu, H., Li, H., Sun, S., Pan, X., Zhang, X., Zhang, J., Wang, M., Yang, Y., et al. (2026) · Scientific Reports · doi:10.1038/s41598-026-49945-7 · Cited by 1
“LIPUS, as a physical therapy method approved by the US FDA for clinical use, has demonstrated the potential to regulate stem cell function in various tissues through mechanical force and cavitation effects 30,31 .”
Kondo, H., Fukui, T., Sawauchi, K., Kumabe, Y., Nishida, R., Jonathan, Fukumoto, G., Kuroda, R., & Oe, K. (2026) · Bone · doi:10.1016/j.bone.2026.117948
Cao, X., Hu, J., Pang, Q., Jiang, Q., Chen, S., & Luo, B. (2026) · Journal of Functional Biomaterials · doi:10.3390/jfb17060278
“In addition, orthopedic studies suggest that LIPUS and electromagnetic stimulation have been clinically investigated for bone repair, although the strength and scope of the evidence remain variable [126].”
Berni, M., Caliogna, L., Lenta, E., Acquafredda, G., Valsecchi, C., Croce, S., Bozzinì, S., Comoli, P., Mosconi, M., Pasta, G., et al. (2026) · Journal of Functional Biomaterials · doi:10.3390/jfb17080356
“In 1979, they were approved by the FDA as a safe and effective treatment for bone fracture healing, non-union, congenital pseudoarthrosis, and failed spinal fusions [4–6].”
Use of Biophysical Stimulation Therapy in Surgically Treated Acute Scaphoid Fractures
Scarlato, C., Vizcay, M., Denami, N., Ghezzi, A., & Pajardi, G. E. (2026) · Plastic & Reconstructive Surgery Global Open · doi:10.1097/gox.0000000000008093
Fracture healing: from molecular and cellular mechanisms to therapeutic strategies
Staubli, F., ten Ham, R. M. T., Bergsma, J. E., Gawlitta, D., & Man, K. (2026) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-026-02967-z · Cited by 2
Simfukwe, R., Aovare, P., & Chilunga, F. P. (2026) · medRxiv · doi:10.64898/2026.09.23.26363775
Metadata
- Authors
- Hannemann, P. F. W., Mommers, E. H. H., Schots, J. P. M., Brink, P. R. G., & Poeze, M.
- Affiliations
- Maastricht University Medical Centre (NL)
- Corresponding author
- Hannemann, P. F. W.
- Venue
- Archives of Orthopaedic and Trauma Surgery
- Published
- 2014-06-04
- Volume
- 134
- Issue
- 8
- Pages
- 1093-1106
- ISSN
- 0936-8051 (ISSN-L)
- 1434-3916
- OpenAlex
- W1970201788
- Cited by
- 151
- References
- 35
- Citations by year
- 2026: 9 · 2025: 5 · 2024: 16 · 2023: 12 · 2022: 6 · 2021: 12 · 2020: 12 · 2019: 15 · 2018: 19 · 2017: 16 · 2016: 14 · 2015: 14 · 2014: 1
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Archives of Orthopaedic and Trauma Surgery (publishedVersion)
- PubMed (publishedVersion)
- Research Publications (Maastricht University) (submittedVersion)
- Funders
- ZonMw
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
- Keywords
- low-intensity pulsed ultrasound, pulsed electromagnetic fields, bone growth stimulation, acute fractures, nonunion, diaphyseal fractures, upper extremity fractures
- MeSH terms
- Adult, Electromagnetic Fields, Electric Stimulation Therapy, Humans, Ultrasonic Therapy, Randomized Controlled Trials as Topic, Treatment Outcome, Fracture Healing, Fractures, Bone, Magnetic Field Therapy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.