Treatment of ununited tibial diaphyseal fractures with pulsing electromagnetic fields.
Abstract
One hundred and twenty-five patients with one hundred and twenty-seven ununited fractures of the tibial diaphysis were treated exclusively with pulsing electromagnetic fields. The over-all success rate in healing of the fracture with this surgically non-invasive out-patient method was 87 per cent. The success rate was not materially affected by the age or sex of the patient, the length of prior disability, the number of previous failed operations, or the presence of infection or metal fixation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Biochemistry and Physiology of Bone
(1956) · Journal of the American Medical Association · doi:10.1001/jama.1956.02970180082039 · Cited by 861
Generation of electric potentials by bone in response to mechanical stress
Bassett, C. A. L., & Becker, R. O. (1962) · Science · doi:10.1126/science.137.3535.1063 · Cited by 778
Self-citationEffects of Electric Currents on Bone In Vivo
BASSETT, C. A. L., PAWLUK, R. J., & BECKER, R. O. (1964) · Nature · doi:10.1038/204652a0 · Cited by 542
Self-citationPiezoelectric Effects in Collagen
Fukada, E., & Yasuda, I. (1964) · Japanese Journal of Applied Physics · doi:10.1143/jjap.3.117 · Cited by 443
Augmentation of Bone Repair by Inductively Coupled Electromagnetic Fields
Andrew, C., Bassett, L., Pawluk, R. J., & Pilla, A. A. (1974) · Science · doi:10.1126/science.184.4136.575 · Cited by 385
Biologic significance of piezoelectricity
Bassett, C. A. L. (1967) · Calcified Tissue Research · doi:10.1007/bf02008098 · Cited by 338
Self-citationACCELERATION OF FRACTURE REPAIR BY ELECTROMAGNETIC FIELDS. A SURGICALLY NONINVASIVE METHOD
Bassett, C. A. L., Pawluk, R. J., & Pilla, A. A. (1974) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1974.tb26794.x · Cited by 285
Self-citationBASSETT, C. A. L., PILLA, A. A., & PAWLUK, R. J. (1977) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197705000-00017 · Cited by 270
Self-citationCurrent Concepts of Bone Formation
Bassett, C. A. L. (1962) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196244060-00020 · Cited by 259
Self-citationFibrous proteins, scientific, industrial, and medical aspects
Parry, D. A. D., & Creamer, L. K. (1979) · Medical Entomology and Zoology · Cited by 149
Cited by
Broughton, G., Janis, J. E., & Attinger, C. E. (2006) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000222562.60260.f9 · Cited by 917
Enhancement of fracture-healing.
Einhorn, T. A. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199506000-00016 · Cited by 772
Thrivikraman, G., Boda, S. K., & Basu, B. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.003 · Cited by 384
Electrical stimulation and piezoelectric biomaterials for bone tissue engineering applications.
Khare, D., Basu, B., & Dubey, A. K. (2020) · PubMed · doi:10.1016/j.biomaterials.2020.120280 · Cited by 354
A double-blind trial of pulsed electromagnetic fields for delayed union of tibial fractures
Sharrard, W. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b3.2187877 · Cited by 341
Metadata
- Authors
- Bassett, C. A., Mitchell, S. N., & Gaston, S. R.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1981-04
- Volume
- 63
- Issue
- 4
- Pages
- 511-523
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W187553757
- Cited by
- 349
- References
- 21
- FWCI
- 16.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Treatment of ununited tibial diaphyseal fractures with pulsing electromagnetic fields. https://app.cochat.ai/papers/10.2106/00004623-198163040-00001
- The paper
- Bassett, C. A., Mitchell, S. N., & Gaston, S. R. (1981). Treatment of ununited tibial diaphyseal fractures with pulsing electromagnetic fields. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-198163040-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.