Freezing of gait and fall detection in Parkinson’s disease using wearable sensors: a systematic review
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Despite the large number of studies that have investigated the use of wearable sensors to detect gait disturbances such as Freezing of gait (FOG) and falls, there is little consensus regarding appropriate methodologies for how to optimally apply such devices. Here, an overview of the use of wearable systems to assess FOG and falls in Parkinson's disease (PD) and validation performance is presented. A systematic search in the PubMed and Web of Science databases was performed using a group of concept key words. The final search was performed in January 2017, and articles were selected based upon a set of eligibility criteria. In total, 27 articles were selected. Of those, 23 related to FOG and 4 to falls. FOG studies were performed in either laboratory or home settings, with sample sizes ranging from 1 PD up to 48 PD presenting Hoehn and Yahr stage from 2 to 4. The shin was the most common sensor location and accelerometer was the most frequently used sensor type. Validity measures ranged from 73-100% for sensitivity and 67-100% for specificity. Falls and fall risk studies were all home-based, including samples sizes of 1 PD up to 107 PD, mostly using one sensor containing accelerometers, worn at various body locations. Despite the promising validation initiatives reported in these studies, they were all performed in relatively small sample sizes, and there was a significant variability in outcomes measured and results reported. Given these limitations, the validation of sensor-derived assessments of PD features would benefit from more focused research efforts, increased collaboration among researchers, aligning data collection protocols, and sharing data sets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000100 · Cited by 28,164 · cited 2×
“The search query, based on the PICO strategy [31], included Parkinson’s disease representing the Population, wearable, sensors, device representing the Intervention and falls or freezing of gait representing the Comparison.”
MethodLiberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00136 · Cited by 10,349
Parkinson's disease: clinical features and diagnosis
Jankovic, J. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.131045 · Cited by 5,720 · cited 1×
“Parkinson’s disease (PD) is a progressive neurodegenerative disease characterized by four major motor signs: rest tremor, rigidity, bradykinesia, and postural instability [1].”
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Freezing of gait: moving forward on a mysterious clinical phenomenon
Nutt, J. G., Bloem, B. R., Giladi, N., Hallett, M., Horak, F. B., & Nieuwboer, A. (2011) · The Lancet Neurology · doi:10.1016/s1474-4422(11)70143-0 · Cited by 1,304
Self-citationBloem, B. R., Hausdorff, J. M., Visser, J. E., & Giladi, N. (2004) · Movement Disorders · doi:10.1002/mds.20115 · Cited by 1,297 · cited 1×
“In addition, falls are also related to physical injury [61], high hospitalization cost [62], and social/psychological impact [63], either on their own or due to the anticipatory fear of falling [64].”
BackgroundSelf-citationSydney multicenter study of Parkinson's disease: Non‐L‐dopa–responsive problems dominate at 15 years
Hely, M. A., Morris, J. G. L., Reid, W. G. J., & Trafficante, R. (2005) · Movement Disorders · doi:10.1002/mds.20324 · Cited by 1,050 · cited 1×
“With disease progression, the increase of FOG and falling episodes, as well as the decrease in effectiveness of dopaminergic therapy amplify the burden related to these symptoms [6, 12, 14].”
BackgroundProspective assessment of falls in Parkinson's disease
Bloem, B. R., Grimbergen, Y. A. M., Cramer, M., Willemsen, M., & Zwinderman, A. H. (2001) · Journal of Neurology · doi:10.1007/s004150170047 · Cited by 865 · cited 2×
“Falls are common and disabling, even in early PD [61].”
BackgroundSelf-citationParkinson's Disease and Parkinsonism: Neuropathology
Dickson, D. W. (2012) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a009258 · Cited by 847
Wearable Assistant for Parkinson’s Disease Patients With the Freezing of Gait Symptom
Bachlin, M., Plotnik, M., Roggen, D., Maidan, I., Hausdorff, J. M., Giladi, N., & Troster, G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036165 · Cited by 693 · cited 1×
“However, there is a growing interest in non-pharmacological interventions, such as physiotherapy [15], deep brain stimulation [16], or cueing devices [17, 18].”
Background
Cited by
The emergence of AI-based wearable sensors for digital health technology: a review
Shajari, S., Kuruvinashetti, K., Komeili, A., & Sundararaj, U. (2023) · Sensors · doi:10.3390/s23239498 · Cited by 535
Long-term unsupervised mobility assessment in movement disorders
Warmerdam, E., Hausdorff, J. M., Atrsaei, A., Zhou, Y., Mirelman, A., Aminian, K., Espay, A. J., Hansen, C., Evers, L. J. W., Keller, A., et al. (2020) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30397-7 · Cited by 306
Self-citationImproving Access to Care: Telemedicine Across Medical Domains
Barbosa, W., Zhou, K., Waddell, E., Myers, T., & Dorsey, E. R. (2021) · Annual Review of Public Health · doi:10.1146/annurev-publhealth-090519-093711 · Cited by 299
Lonini, L., Dai, A., Shawen, N., Simuni, T., Poon, C., Shimanovich, L., Daeschler, M., Ghaffari, R., Rogers, J. A., & Jayaraman, A. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0071-z · Cited by 209
Wearable-Sensor-Based Detection and Prediction of Freezing of Gait in Parkinson’s Disease: A Review
Pardoel, S., Kofman, J., Nantel, J., & Lemaire, E. D. (2019) · Sensors · doi:10.3390/s19235141 · Cited by 201
Johansson, D., Malmgren, K., & Alt Murphy, M. (2018) · Journal of Neurology · doi:10.1007/s00415-018-8786-y · Cited by 188
Measuring freezing of gait during daily-life: an open-source, wearable sensors approach
Mancini, M., Shah, V. V., Stuart, S., Curtze, C., Horak, F. B., Safarpour, D., & Nutt, J. G. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00774-3 · Cited by 182
Clinical and methodological challenges for assessing freezing of gait: Future perspectives
Mancini, M., Bloem, B. R., Horak, F. B., Lewis, S. J. G., Nieuwboer, A., & Nonnekes, J. (2019) · Movement Disorders · doi:10.1002/mds.27709 · Cited by 173
“Specifically, among the different sensors used, accelerometers were the most widely used, either as a single sensor or in combination with gyroscopes or magnetometers.(34) The location used mostly was the shin in 66% of the studies, followed by the waist (33%; see Fig.”
BackgroundMethodSelf-citationToward a Wearable System for Predicting Freezing of Gait in People Affected by Parkinson's Disease
Demrozi, F., Bacchin, R., Tamburin, S., Cristani, M., & Pravadelli, G. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2952618 · Cited by 86
“sensors to detect FoG detection reported 73–100% sensitivity and 67–100% specificity [22].”
BackgroundImproving Safety Performance of Construction Workers through Learning from Incidents
Chan, A. P. C., Guan, J., Choi, T. N. Y., Yang, Y., Wu, G., & Lam, E. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20054570 · Cited by 55
Kwon, H., Clifford, G. D., Genias, I., Bernhard, D., Esper, C. D., Factor, S. A., & McKay, J. L. (2023) · Sensors · doi:10.3390/s23041766 · Cited by 24
(2023) · doi:10.1101/2023.01.13.23284535 · Cited by 24
Medication management initiatives using wearable devices: scoping review
Iino, H., Kizaki, H., Imai, S., & Hori, S. (2024) · JMIR Human Factors · doi:10.2196/57652 · Cited by 12
Metadata
- Authors
- Silva de Lima, A. L., Evers, L. J. W., Hahn, T., Bataille, L., Hamilton, J. L., Little, M. A., Okuma, Y., Bloem, B. R., & Faber, M. J.
- Venue
- Journal of Neurology
- Published
- 2017-03-01
- Volume
- 264
- Issue
- 8
- Pages
- 1642-1654
- ISSN
- 0012-1037 (ISSN-L)
- 0340-5354
- 1432-1459
- OpenAlex
- W2592073184
- Cited by
- 191
- References
- 63
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.