The DOI matches its Crossref record; 125 of the 125 references it cites were found in a registry or an index.
Mass spectrometry imaging with high resolution in mass and space
Open accessAbstract
Mass spectrometry (MS) imaging links molecular information and the spatial distribution of analytes within a sample. In contrast to most histochemical techniques, mass spectrometry imaging can differentiate molecular modifications and does not require labeling of targeted compounds. We have recently introduced the first mass spectrometry imaging method that provides highly specific molecular information (high resolution and accuracy in mass) at cellular dimensions (high resolution in space). This method is based on a matrix-assisted laser desorption/ionization (MALDI) imaging source working at atmospheric pressure which is coupled to an orbital trapping mass spectrometer. Here, we present a number of application examples and demonstrate the benefit of 'mass spectrometry imaging with high resolution in mass and space.' Phospholipids, peptides and drug compounds were imaged in a number of tissue samples at a spatial resolution of 5-10 μm. Proteins were analyzed after on-tissue tryptic digestion at 50-μm resolution. Additional applications include the analysis of single cells and of human lung carcinoma tissue as well as the first MALDI imaging measurement of tissue at 3 μm pixel size. MS image analysis for all these experiments showed excellent correlation with histological staining evaluation. The high mass resolution (R = 30,000) and mass accuracy (typically 1 ppm) proved to be essential for specific image generation and reliable identification of analytes in tissue samples. The ability to combine the required high-quality mass analysis with spatial resolution in the range of single cells is a unique feature of our method. With that, it has the potential to supplement classical histochemical protocols and to provide new insights about molecular processes on the cellular level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
The OBO Foundry: coordinated evolution of ontologies to support biomedical data integration
The OBI Consortium, Smith, B., Ashburner, M., Rosse, C., Bard, J., Bug, W., Ceusters, W., Goldberg, L. J., Eilbeck, K., Ireland, A., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1346 · Cited by 2,560
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234
Listeria Pathogenesis and Molecular Virulence Determinants
Vázquez-Boland, J. A., Kuhn, M., Berche, P., Chakraborty, T., Domı́nguez-Bernal, G., Goebel, W., González-Zorn, B., Wehland, J., & Kreft, J. (2001) · Clinical Microbiology Reviews · doi:10.1128/cmr.14.3.584-640.2001 · Cited by 2,152
Santos, C. R., & Schulze, A. (2012) · The FEBS Journal · doi:10.1111/j.1742-4658.2012.08644.x · Cited by 1,335
Stoeckli, M., Chaurand, P., Hallahan, D. E., & Caprioli, R. M. (2001) · Nature Medicine · doi:10.1038/86573 · Cited by 1,172
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Electrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis
Makarov, A. (2000) · Analytical Chemistry · doi:10.1021/ac991131p · Cited by 1,009
Karas, M., Bachmann, D., & Hillenkamp, F. (1985) · Analytical Chemistry · doi:10.1021/ac00291a042 · Cited by 935
Cited by
Current approaches and challenges for the metabolite profiling of complex natural extracts
Wolfender, J.-L., Marti, G., Thomas, A., & Bertrand, S. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.091 · Cited by 635
Mass Spectrometry Imaging of Biomolecular Information
Spengler, B. (2015) · Analytical Chemistry · doi:10.1021/ac504543v · Cited by 290
Self-citationBitto, V., Hönscheid, P., Besso, M. J., Sperling, C., Kurth, I., Baumann, M., & Brors, B. (2024) · npj Systems Biology and Applications · doi:10.1038/s41540-024-00385-x · Cited by 6
Metadata
- Authors
- Römpp, A., & Spengler, B.
- Venue
- Histochemistry and Cell Biology
- Published
- 2013-05-08
- Volume
- 139
- Issue
- 6
- Pages
- 759-783
- ISSN
- 0948-6143 (ISSN-L)
- 1432-119X
- OpenAlex
- W2044712639
- Cited by
- 358
- References
- 125
- FWCI
- 16.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mass spectrometry imaging with high resolution in mass and space. https://app.cochat.ai/papers/10.1007/s00418-013-1097-6
- The paper
- Römpp, A., & Spengler, B. (2013). Mass spectrometry imaging with high resolution in mass and space. Histochemistry and Cell Biology. https://doi.org/10.1007/s00418-013-1097-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.