Cited by 156Body Composition Measurement TechniquesSports Performance and TrainingMuscle activation and electromyography studies

Validity of ultrasonograph muscle thickness measurements for estimating muscle volume of knee extensors in humans

Miyatani, Masae, Kanehisa, Hiroaki, Kuno, Shinya, Nishijima, Takahiko, Fukunaga, Tetsuo·2002·European Journal of Applied Physiology

Abstract

This study aimed to investigate the suitability of using ultrasonograph muscle thickness (MT) measurements to estimate the muscle volume (MV) of the quadriceps femoris as an alternative approach to magnetic resonance imaging (MRI). The subjects were 46 men aged from 20 to 70 years who were randomly allocated to either a validation or a cross-validation group. In the validation group, multiple and simple regression equations, which used a set of MT values determined at mid-thigh and thigh length (1) and the product of pi, (MT/2)2, and l [pi x (MT/2)2 x l], respectively, as independent variables, were derived to estimate the MV measured by MRI. Because the two equations were cross-validated, the data from the two groups were pooled to generate the final prediction equations: MV (cm3)=(MT x 311.732)+(l x 53.346) -2058.529 as the multiple regression equation and MV (cm3) = [pi x (MT/ 2)2 x l] x 1.1176+663.040 as the simple regression equation. In the multiple regression equation, MT explained 75% of the variation in the MV measured by MRI. The r2 and the standard error of the estimate (SEE) of the equations were 0.824 and 175.6 cm3 (10.6%), respectively, for the multiple regression equation and 0.829 and 173.7 cm3 (10.5%), respectively, for the simple regression equation. Thus, the present results indicate that ultrasonograph MT measurements at mid-thigh are useful for estimating the MV of knee extensors. However, the observed SEE values suggest that the prediction equation obtai…

Integrity signals

Registry

Crossref · 10.1007/s00421-001-0533-9

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Pooling the spectrum of methods for knee extensor mass/size and strength was done due to their high validity and reliability minimizing selection bias.

    “We pooled the aforementioned spectrum of methods due to their high validity and reliability minimizing the selection bias (63–66).”

Cited by

Sorted by citations

Authors
Miyatani, M., Kanehisa, H., Kuno, S., Nishijima, T., & Fukunaga, T.
Affiliations
  • The University of Tokyo (JP)
  • University of Tsukuba (JP)
Corresponding author
Fukunaga, Tetsuo
Venue
European Journal of Applied Physiology
Published
2001-11-29
Volume
86
Issue
3
Pages
203-208
ISSN
  • 0020-9376 (ISSN-L)
  • 1439-6319
  • 1439-6327
OpenAlex
W2024401125
Cited by
156
References
0
Citations by year
2026: 5 · 2025: 3 · 2024: 6 · 2023: 9 · 2022: 5 · 2021: 10 · 2020: 6 · 2019: 9 · 2018: 6 · 2017: 4 · 2016: 6 · 2015: 8 · 2014: 12 · 2013: 15 · 2012: 10
FWCI
1.39
Type
journal article
Language
en
Open access
closed
Locations
  • European Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
muscle thickness, muscle volume estimation, quadriceps, knee extensors, ultrasonic measurement, prediction equations, MRI validation, thigh length, cross-validation
MeSH terms
Adult, Aged, Humans, Knee Joint, Magnetic Resonance Imaging, Male, Middle Aged, Regression Analysis, Ultrasonography, Reproducibility of Results, Muscle, Skeletal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review