Accuracy, reliability, linearity of Accutrend and Lactate Pro versus EBIO plus analyzer
Open accessAbstract
The accuracy, reliability and linearity in two hand-portable lactate analyzers, the Accutrend Lactate® (AL) and the Lactate Pro™ (LP) versus the EBIO® plus analyzer (EP) were evaluated. For accuracy, duplicate samples recorded on both the AL and LP revealed an overall average difference versus EP (P < 0.05). The limits of agreement between AL and EP were −0.7 to +1.0, and −1.3 to +1.5 mM between LP and EP. Reliability of AL and LP was assessed at different lactate concentrations; coefficient of variation ranged between 1.8 and 3.3% for AL and between 2.8 and 5.0% for LP. AL and LP had a good reliability for intra-, inter-analyzers, and between test strips (ICC r = 0.999). The linearity was determined versus the EP as reference. The slope coefficient of AL (1.0394) was closer to 1 than that of LP (1.1053). On these bases, AL and LP can be individually considered suitable for the sports research field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Justification of the 4-mmol/l lactate threshold
Heck, H., Mader, A., Hess, G., Mücke, S., Müller, R., & Hollmann, W. (1985) · International Journal of Sports Medicine · doi:10.1055/s-2008-1025824 · Cited by 888
Research works printed but not linked: 19
- Baldari C, Guidetti L (2000) A simple method for individual anaerobic threshold as predictor of max lactate steady state. Med Sci Sports Exerc 32:1798–1802. doi: 10.1097/00005768-200010000-00022 · DOI
- Baldari C, Videira M, Madeira F, Sergio J, Guidetti L (2004) Lactate removal during active recovery related to the individual anaerobic and ventilatory thresholds in soccer players. Eur J Appl Physiol 93:224–230. doi: 10.1007/s00421-004-1203-5 · DOI
- Beneke R, Hütler M, Jung M, Leithäuser RM (2005) Modeling the blood lactate kinetics at maximal short-term exercise conditions in children, adolescents, and adults. J Appl Physiol 99:499–504. doi: 10.1152/japplphysiol.00062.2005 · DOI
- Bentley DJ, McNaughton LR, Thompson D, Vleck VE (2001) Peak power output, the lactate threshold, and time trial performance in cyclists. Med Sci Sports Exerc 33:2077–2081. doi: 10.1097/00005768-200112000-00016 · DOI
- Bishop D (2001) Evaluation of the Accusport Lactate Analyser. Int J Sports Med 22:525–530. doi: 10.1055/s-2001-17611 · DOI
- Buckley JD, Bourdon PC, Woolford SM (2003) Effect of measuring blood lactate concentrations using different automated lactate analyzers on blood lactate transition thresholds. J Sci Med Sport 6:408–421. doi: 10.1016/S1440-2440(03)80267-0 · DOI
- Carvalho JF, Masako Masuda O, Pompeu AMS (2005) Methods for diagnosis and control of aerobic training in rats based on lactate threshold. Comp Biochem Physiol A 140:409–413. doi: 10.1016/j.cbpb.2004.12.002 · doi:10.1016/j.cbpb.2004.12.002
- Fell JW, Rayfield JP, Gulbin PT, Gaffney PT (1998) Evaluation of the Accusport Lactate Analyser. Int J Sports Med 19:199–204. doi: 10.1055/s-2007-971904 · DOI
- Goodwin ML, Harris JE, Hernandez A, Gladden LB (2007) Blood lactate measurements and analysis during exercise: a guide for clinicians. J Diabetes Sci Technol 1:558–569 · DOI · Paper page
- Mc Naughton LR, Thompson D, Philips G, Backx K, Crickmore L (2002) A comparison of the Lactate Pro, Accusport, Analox GM7 and Kodak Ektachem Lactate Analysers in normal, hot and humid conditions. Int J Sports Med 23:130–135. doi: 10.1055/s-2002-20133 · DOI
- Medbø JI, Mamen A, Holt Olsen O, Evertsen F (2000) Examination of four different instruments for measuring blood lactate concentration. Scand J Clin Lab Invest 60:367–380. doi: 10.1080/003655100750019279 · DOI
- Nordstrom L, Chua S, Roy A, Arulkumaran S (1998) Quality assessment of two lactate test strip methods suitable for obstetric use. J Perinat Med 26:83–88 · DOI
- Nordstrom L, Achanna S, Naka K, Arulkumaran S (2001) Fetal and maternal lactate increase during active second stage of labour. BJOG 108:263–268
- Oosthuyse T, Carter RN (1999) Plasma lactate decline during passive recovery from high-intensity exercise. Med Sci Sports Exerc 31:670–674. doi: 10.1097/00005768-199905000-00008 · DOI
- Pinnington H, Dawson B (2001) Examination of the validity and reliability of the Accusport blood lactate analyser. J Sci Med Sport 4:129–138. doi: 10.1016/S1440-2440(01)80014-1 · DOI
- Pyne DB, Martin DT, Logan A (2000) Evaluation of the Lactate Pro blood lactate analyser. Eur J Appl Physiol 82:112–116. doi: 10.1007/s004210050659 · DOI · Paper page
- Pyne DB, Lee H, Swanwick KM (2001) Monitoring the lactate threshold in world-ranked swimmers. Med Sci Sports Exerc 33:291–297. doi: 10.1097/00005768-200102000-00019 · DOI · Paper page
- Van Someren KA, Howatson G, Nunan D, Thatcher R, Shave R (2005) Comparison of the Lactate Pro and Analox GM7 blood lactate analysers. J Sports Med 26:657–661. doi: 10.1055/s-2004-830337 · DOI
- Westgren M, Kublickas M, Kruger K (1999) Role of lactate measurements during labor. Obstet Gynecol Surv 54:43–48. doi: 10.1097/00006254-199901000-00023 · DOI
Cited by
Acute exercise improves motor memory: exploring potential biomarkers.
Skriver, K., Roig, M., Lundbye-Jensen, J., Pingel, J., Helge, J. W., Kiens, B., & Nielsen, J. B. (2014) · Neurobiology of Learning and Memory · doi:10.1016/j.nlm.2014.08.004 · Cited by 326
Evaluation of three portable blood lactate analysers: Lactate Pro, Lactate Scout and Lactate Plus
Tanner, R. K., Fuller, K. L., & Ross, M. L. R. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1379-9 · Cited by 274
A Single Bout of Exercise Improves Motor Memory
Roig, M., Skriver, K., Lundbye-Jensen, J., Kiens, B., & Nielsen, J. B. (2012) · PLoS ONE · doi:10.1371/journal.pone.0044594 · Cited by 267
Reliability and validity of the lactate Pro 2 analyzer
Crotty, N. M., Boland, M., Mahony, N., Donne, B., & Fleming, N. (2021) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2020.1865966 · Cited by 50
A Validation Study of a Noninvasive Lactate Threshold Device
McMorries, R. M., Joubert, D. P., Jones, E. J., & Faries, M. D. (2019) · International Journal of Exercise Science · doi:10.70252/loed6863 · Cited by 14
Metadata
- Authors
- Baldari, C., Bonavolontà, V., Emerenziani, G. P., Gallotta, M. C., Silva, A. J., & Guidetti, L.
- Venue
- European Journal of Applied Physiology
- Published
- 2009-06-14
- Volume
- 107
- Issue
- 1
- Pages
- 105-111
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W1990680297
- Cited by
- 171
- References
- 2
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.springer.com/tdm (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.