Accuracy, reliability, linearity of Accutrend and Lactate Pro versus EBIO plus analyzer
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The accuracy, reliability and linearity in two hand-portable lactate analyzers, the Accutrend Lactate® (AL) and the Lactate Pro™ (LP) versus the EBIO® plus analyzer (EP) were evaluated. For accuracy, duplicate samples recorded on both the AL and LP revealed an overall average difference versus EP (P < 0.05). The limits of agreement between AL and EP were −0.7 to +1.0, and −1.3 to +1.5 mM between LP and EP. Reliability of AL and LP was assessed at different lactate concentrations; coefficient of variation ranged between 1.8 and 3.3% for AL and between 2.8 and 5.0% for LP. AL and LP had a good reliability for intra-, inter-analyzers, and between test strips (ICC r = 0.999). The linearity was determined versus the EP as reference. The slope coefficient of AL (1.0394) was closer to 1 than that of LP (1.1053). On these bases, AL and LP can be individually considered suitable for the sports research field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Justification of the 4-mmol/l lactate threshold
Heck, H., Mader, A., Hess, G., Mücke, S., Müller, R., & Hollmann, W. (1985) · International Journal of Sports Medicine · doi:10.1055/s-2008-1025824 · Cited by 888 · cited 2×
“…by diVerent analyzer should be kept in mind when applying a protocol dealing with a Wxed absolute value, such as 2 and 4 mM lactate thresholds (Heck et al. 1985), 0.5 mM increments’ method for lactate threshold (Baldari and Guidetti 2000), especially if the protocol was validated using one…”
MethodInfluentialBlood Lactate Measurements and Analysis during Exercise: A Guide for Clinicians
Goodwin, M. L., Harris, J. E., Hernández, A., & Gladden, L. B. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100414 · Cited by 554 · cited 2×
“Wingate anaerobic power test); the most observed and detected lactate concentrations in various sports are deWnitely lower (Goodwin et al. 2007).”
Evaluation of the Lactate Pro blood lactate analyser
Pyne, D. B., Boston, T., Martin, D. T., & Logan, A. (2000) · European Journal of Applied Physiology · doi:10.1007/s004210050659 · Cited by 313 · cited 6×
“Anyway, in some previous works, there was a lack of direct comparison between the two most common handportable analyzers, AL (Bishop 2001) and LP (Pyne et al. 2000).”
BackgroundMethodInfluentialMonitoring the lactate threshold in world-ranked swimmers
PYNE, D. B., LEE, H., & SWANWICK, K. M. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200102000-00019 · Cited by 236 · cited 2×
“As today trainers and sport scientist prefer to work and to talk about kinetic of lactate more than instantaneous lactate value (Baldari and Guidetti 2000; Baldari et al. 2004; Beneke et al. 2005; Bentley et al. 2001; Oosthuyse and Carter 1999; Pyne et al. 2001; Stegmann et al. 1981), measures repeated over the time w…”
Fetal and maternal lactate increase during active second stage of labour
Nordström, L., Achanna, S., Naka, K., & Arulkumaran, S. (2001) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2001.00034.x · Cited by 171
Beneke, R., Hütler, M., Jung, M., & Leithäuser, R. M. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00062.2005 · Cited by 170 · cited 1×
“…scientist prefer to work and to talk about kinetic of lactate more than instantaneous lactate value (Baldari and Guidetti 2000; Baldari et al. 2004; Beneke et al. 2005; Bentley et al. 2001; Oosthuyse and Carter 1999; Pyne et al. 2001; Stegmann et al. 1981), measures repeated over the time with the…”
BackgroundPeak power output, the lactate threshold, and time trial performance in cyclists
BENTLEY, D. J., MCNAUGHTON, L. R., THOMPSON, D., VLECK, V. E., & BATTERHAM, A. M. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200112000-00016 · Cited by 138 · cited 2×
“…work and to talk about kinetic of lactate more than instantaneous lactate value (Baldari and Guidetti 2000; Baldari et al. 2004; Beneke et al. 2005; Bentley et al. 2001; Oosthuyse and Carter 1999; Pyne et al. 2001; Stegmann et al. 1981), measures repeated over the time with the same instruments…”
BackgroundExamination of four different instruments for measuring blood lactate concentration
Medbø, J. I., Mamen, A., Holt Olsen, O., & Evertsen, E. (2000) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655100750019279 · Cited by 122 · cited 10×
“Results of our ANOVA analysis indicate that the two portable analyzers cannot be used interchangeably, and in a single study researchers must choose and keep the same instrument throughout all the measurements as it has been already suggested by Buckley et al. (2003) and Medbø et al. (2000).”
BackgroundMethodResultInfluential
Research works printed but not linked: 1
- Carvalho JF, Masako Masuda O, Pompeu AMS (2005) Methods for diagnosis and control of aerobic training in rats based on lactate threshold. Comp Biochem Physiol A 140:409–413. doi: 10.1016/j.cbpb.2004.12.002 · doi:10.1016/j.cbpb.2004.12.002
Cited by
Acute exercise improves motor memory: exploring potential biomarkers.
Skriver, K., Roig, M., Lundbye-Jensen, J., Pingel, J., Helge, J. W., Kiens, B., & Nielsen, J. B. (2014) · Neurobiology of Learning and Memory · doi:10.1016/j.nlm.2014.08.004 · Cited by 326
Evaluation of three portable blood lactate analysers: Lactate Pro, Lactate Scout and Lactate Plus
Tanner, R. K., Fuller, K. L., & Ross, M. L. R. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1379-9 · Cited by 274
A Single Bout of Exercise Improves Motor Memory
Roig, M., Skriver, K., Lundbye-Jensen, J., Kiens, B., & Nielsen, J. B. (2012) · PLoS ONE · doi:10.1371/journal.pone.0044594 · Cited by 267
Mohr, M., Draganidis, D., Chatzinikolaou, A., Barbero-Álvarez, J. C., Castagna, C., Douroudos, I., Avloniti, A., Margeli, A., Papassotiriou, I., Flouris, A. D., et al. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-015-3245-2 · Cited by 216
“Blood lactate concentration was assessed using a handportable analyzer (Accutrend Plus, Roche Diagnostics, Basel, Switzerland) as described (Baldari et al. 2009).”
Reliability and validity of the lactate Pro 2 analyzer
Crotty, N. M., Boland, M., Mahony, N., Donne, B., & Fleming, N. (2021) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2020.1865966 · Cited by 50
A Validation Study of a Noninvasive Lactate Threshold Device
McMorries, R. M., Joubert, D. P., Jones, E. J., & Faries, M. D. (2019) · International Journal of Exercise Science · doi:10.70252/loed6863 · Cited by 14
de Jesus Gomes, G., Diniz Magalhães, C. O., Queiroz, I. P., Alves de Andrade, J., Chaves Garcia, B. C., Ramalho de Souza Pereira, R., Moreira Costa, J. M., Cassilhas, R. C., Villela, D. C., Castro de Magalhães, F., et al. (2025) · European Journal of Sport Science · doi:10.1002/ejsc.12302 · Cited by 5
Metadata
- Authors
- Baldari, C., Bonavolontà, V., Emerenziani, G. P., Gallotta, M. C., Silva, A. J., & Guidetti, L.
- Venue
- European Journal of Applied Physiology
- Published
- 2009-06-14
- Volume
- 107
- Issue
- 1
- Pages
- 105-111
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W1990680297
- Cited by
- 171
- References
- 23
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.springer.com/tdm (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.