Sensory mechanotransduction at membrane-matrix interfaces
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Sensory cells specialized to detect extremely small mechanical changes are common to the auditory and somatosensory systems. It is widely accepted that mechanosensitive channels form the core of the mechanoelectrical transduction in hair cells as well as the somatic sensory neurons that underlie the sense of touch and mechanical pain. Here, we will review how the activation of such channels can be measured in a meaningful physiological context. In particular, we will discuss the idea that mechanosensitive channels normally occur in transmembrane complexes that are anchored to extracellular matrix components (ECM) both in vitro and in vivo. One component of such complexes in sensory neurons is the integral membrane scaffold protein STOML3 which is a robust physiological regulator of native mechanosensitive currents. In order to better characterize such channels in transmembrane complexes, we developed a new electrophysiological method that enables the quantification of mechanosensitive current amplitude and kinetics when activated by a defined matrix movement in cultured cells. The results of such studies strongly support the idea that ion channels in transmembrane complexes are highly tuned to detect movement of the cell membrane in relation to the ECM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezo1 and Piezo2 Are Essential Components of Distinct Mechanically Activated Cation Channels
Coste, B., Mathur, J., Schmidt, M., Earley, T. J., Ranade, S., Petrus, M. J., Dubin, A. E., & Patapoutian, A. (2010) · Science · doi:10.1126/science.1193270 · Cited by 3,316 · cited 11×
“Indeed the profound deficits observed in the sensitivity of native mechanosensitive currents in the absence of STOML3 suggest that in vivo Piezo2 channels are physiologically regulated by the STOML3 protein.”
BackgroundMethodInfluential
Cited by
Mechanically Activated Ion Channels
Ranade, S. S., Syeda, R., & Patapoutian, A. (2015) · Neuron · doi:10.1016/j.neuron.2015.08.032 · Cited by 652
“New methods have been developed to apply mechanical force to specific locations of a cell, including the nerve terminals, or neurites, where mechanically activated ion channels are thought to be functioning (Poole et al., 2015).”
Cox, C. D., Bae, C., Ziegler, L., Hartley, S., Nikolova-Krstevski, V., Rohde, P. R., Ng, C.-A., Sachs, F., Gottlieb, P. A., & Martinac, B. (2016) · Nature Communications · doi:10.1038/ncomms10366 · Cited by 528
Advances in understanding nociception and neuropathic pain
St. John Smith, E. (2018) · Journal of Neurology · doi:10.1007/s00415-017-8641-6 · Cited by 282
Davis, M. J., Earley, S., Li, Y.-S., & Chien, S. (2023) · Physiological Reviews · doi:10.1152/physrev.00053.2021 · Cited by 273
Transduction and encoding sensory information by skin mechanoreceptors
Hao, J., Bonnet, C., Amsalem, M., Ruel, J., & Delmas, P. (2015) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-014-1651-7 · Cited by 71
Metadata
- Authors
- Poole, K., Moroni, M., & Lewin, G. R.
- Venue
- Pflügers Archiv - European Journal of Physiology
- Published
- 2014-07-02
- Volume
- 467
- Issue
- 1
- Pages
- 121-132
- ISSN
- 0031-6768 (ISSN-L)
- 1432-2013
- OpenAlex
- W1976023448
- Cited by
- 38
- References
- 1
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensory mechanotransduction at membrane-matrix interfaces. https://app.cochat.ai/papers/10.1007/s00424-014-1563-6
- The paper
- Poole, K., Moroni, M., & Lewin, G. R. (2015). Sensory mechanotransduction at membrane-matrix interfaces. Pflügers Archiv - European Journal of Physiology. https://doi.org/10.1007/s00424-014-1563-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.