CoChat

Comparison of Trained Clinician Ratings with Expert Ratings of Aspiration on Videofluoroscopic Images from a Randomized Clinical Trial

Open access
Hind, Jacqueline A., Gensler, Gary, Brandt, Diane K., Miller Gardner, Patricia J., Blumenthal, Loreen, Gramigna, Gary D., Kosek, Steven, Lundy, Donna, McGarvey-Toler, Susan, Rockafellow, Susan, Sullivan, Paula A., Villa, Marybell, Gill, Gary D., Lindblad, Anne S., Logemann, Jeri A., Robbins, JoAnne · 2009 · Dysphagia
Cited by 59

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Accurate detection and classification of aspiration is a critical component of videofluoroscopic swallowing evaluation, the most commonly utilized instrumental method for dysphagia diagnosis and treatment. Currently published literature indicates that interjudge reliability for the identification of aspiration ranges from poor to fairly good depending on the amount of training provided to clinicians. The majority of extant studies compared judgments among clinicians. No studies included judgments made during the use of a postural compensatory strategy. The purpose of this study was to examine the accuracy of judgments made by speech-language pathologists (SLPs) practicing in hospitals compared with unblinded expert judges when identifying aspiration and using the 8-point Penetration/Aspiration Scale. Clinicians received extensive training for the detection of aspiration and minimal training on use of the Penetration/Aspiration Scale. Videofluoroscopic data were collected from 669 patients as part of a large, randomized clinical trial and include judgments of 10,200 swallows made by 76 clinicians from 44 hospitals in 11 states. Judgments were made on swallows during use of dysphagia compensatory strategies: chin-down posture with thin liquids and head-neutral posture with thickened liquids (nectar-thick and honey-thick consistencies). The subject population included patients with Parkinson’s disease and/or dementia. Kappa statistics indicate high accuracy for all interventions by SLPs for identification of aspiration (all κ > 0.86) and variable accuracy (range = 69–76%) using the Penetration/Aspiration Scale when compared to expert judges. It is concluded that while the accuracy of identifying the presence of aspiration by SLPs is excellent, more extensive training and/or image enhancement is recommended for precise use of the Penetration/Aspiration Scale.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00455-008-9196-6

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 59

Metadata

Authors
Hind, J. A., Gensler, G., Brandt, D. K., Miller Gardner, P. J., Blumenthal, L., Gramigna, G. D., Kosek, S., Lundy, D., McGarvey-Toler, S., Rockafellow, S., Sullivan, P. A., Villa, M., Gill, G. D., Lindblad, A. S., Logemann, J. A., & Robbins, J.
Venue
Dysphagia
Published
2008-10-25
Volume
24
Issue
2
Pages
211-217
ISSN
  • 0179-051X (ISSN-L)
  • 1432-0460
OpenAlex
W2086282933
Cited by
59
References
2
FWCI
4.29
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Trained Clinician Ratings with Expert Ratings of Aspiration on Videofluoroscopic Images from a Randomized Clinical Trial. https://app.cochat.ai/papers/10.1007/s00455-008-9196-6
The paper
Hind, J. A., Gensler, G., Brandt, D. K., Miller Gardner, P. J., Blumenthal, L., Gramigna, G. D., Kosek, S., Lundy, D., McGarvey-Toler, S., Rockafellow, S., Sullivan, P. A., Villa, M., Gill, G. D., Lindblad, A. S., Logemann, J. A., & Robbins, J. (2009). Comparison of Trained Clinician Ratings with Expert Ratings of Aspiration on Videofluoroscopic Images from a Randomized Clinical Trial. Dysphagia. https://doi.org/10.1007/s00455-008-9196-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.