Differences in postoperative outcomes, function, and cosmesis: open versus robotic thyroidectomy
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
BackgroundRobotic thyroidectomy using a gasless transaxillary approach, first described in 2008, has become popular. This study compared outcomes, including postoperative distress and patient satisfaction, for patients undergoing robotic thyroidectomy with those for patients treated by conventional open thyroidectomy.MethodsOf 84 prospectively enrolled patients, 41 underwent robotic thyroidectomy (the robot group), and 43 received conventional open thyroidectomy (the open group). All the patients were followed up for at least 3 months after surgery. Videolaryngostroboscopic examinations were performed preoperatively and after 1 week and after 3 months postoperatively. Postoperative pain and discomfort were evaluated using a symptom scale. Subjective voice and swallowing changes were assessed by questionnaires; and satisfaction with cosmetic outcome was measured by verbal response at 3 months.ResultsThe two groups were similar in age, gender, type of operation, and final pathologic diagnosis. Although the mean operating time was significantly longer with the robotic technique than with open surgery, there were no between-group differences in postoperative pain or duration of hospital stay. No patient in either group experienced any major postoperative complication. Postoperative discomfort in the neck and swallowing disturbances were significantly more frequent in the open group than in the robot group, both at 1 week and at 3 months after surgery. However, there was no significant between-group difference in subjective voice parameters. At 3 months, the mean cosmetic satisfaction score was significantly higher in the robotic than in the open group.ConclusionAlthough postoperative pain levels and complications were comparable in the two groups, conventional open thyroidectomy requires a shorter operative time. The robotic technique, however, offers several distinct advantages including very good to excellent cosmetic results, reduced postoperative neck discomfort, and fewer adverse swallowing symptoms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Haugen, B. R., Alexander, E. K., Bible, K. C., Doherty, G. M., Mandel, S. J., Nikiforov, Y. E., Pacini, F., Randolph, G. W., Sawka, A. M., Schlumberger, M., et al. (2016) · Thyroid® · doi:10.1089/thy.2015.0020 · Cited by 16,535
Cooper, D. S., Doherty, G. M., Haugen, B. R., Kloos, R. T., Lee, S. L., Mandel, S. J., Mazzaferri, E. L., McIver, B., Pacini, F., Schlumberger, M., et al. (2009) · Thyroid · doi:10.1089/thy.2009.0110 · Cited by 6,707
Development and Validation of the Voice Handicap Index‐10
Rosen, C. A., Lee, A. S., Osborne, J., Zullo, T., & Murry, T. (2004) · The Laryngoscope · doi:10.1097/00005537-200409000-00009 · Cited by 1,410
Endoscopic subtotal parathyroidectomy in patients with primary hyperparathyroidism
Gagner, M. (1996) · Journal of British Surgery · doi:10.1002/bjs.1800830656 · Cited by 883 · cited 1×
“The first application of laparoscopy in endocrine neck surgery was in endoscopic subtotal parathyroidectomy for treatment of secondary hyperparathyroidism, described initially in 1996 [9].”
Endoscopic right thyroid lobectomy
Lirici, M. M., Hüscher, C. S. G., Chiodini, S., Napolitano, C., & Recher, A. (1997) · Surgical Endoscopy · doi:10.1007/s004649900476 · Cited by 637
Kang, S.-W., Lee, S. C., Lee, S. H., Lee, K. Y., Jeong, J. J., Lee, Y. S., Nam, K.-H., Chang, H. S., Chung, W. Y., & Park, C. S. (2009) · Surgery · doi:10.1016/j.surg.2009.09.007 · Cited by 447 · cited 4×
“To the best of our knowledge, this is the first demonstration that robotic thyroidectomy is not only safe for low-risk DTC patients but also offers several advantages in patient outcomes.”
InfluentialSelf-citationRobot-assisted endoscopic surgery for thyroid cancer: experience with the first 100 patients
Kang, S.-W., Jeong, J. J., Yun, J.-S., Sung, T. Y., Lee, S. C., Lee, Y. S., Nam, K.-H., Chang, H. S., Chung, W. Y., & Park, C. S. (2009) · Surgical Endoscopy · doi:10.1007/s00464-009-0366-x · Cited by 390 · cited 3×
“To the best of our knowledge, this is the first demonstration that robotic thyroidectomy is not only safe for low-risk DTC patients but also offers several advantages in patient outcomes.”
InfluentialSelf-citationLombardi, C. P., Raffaelli, M., D’Alatri, L., Marchese, M. R., Rigante, M., Paludetti, G., & Bellantone, R. (2006) · Surgery · doi:10.1016/j.surg.2006.08.008 · Cited by 233 · cited 1×
“The scoring of each item on the SIS-6 ranges from a minimum of 0 (no swallowing alteration) to a maximum of 24 (highest swallowing impairment) (Table 2) [1, 21].”
Prevalence of long-term upper aerodigestive symptoms after uncomplicated bilateral thyroidectomy
Pereira, J. A., Girvent, M., Sancho, J., Parada, C., & Sitges‐Serra, A. (2003) · Surgery · doi:10.1067/msy.2003.58 · Cited by 150 · cited 1×
“Thus, physicians should become aware of the subjective discomfort that commonly occurs after thyroidectomy [2, 21].”
Randomized Controlled Trial of Harmonic Scalpel Use During Thyroidectomy
Miccoli, P., Berti, P., Dionigi, G., D’Agostino, J., Orlandini, C., & Donatini, G. (2006) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.132.10.1069 · Cited by 142 · cited 1×
“This may be attributable to optical magnification of the operative field, to the precise handing possible using a flexible endoscopic instrument, and to a decrease in stress on the paraesophageal space with the use of the Harmonic scalpel [26, 27].”
Deary, I. J., Webb, A. C., MacKenzie, K., Wilson, J. A., & Carding, P. N. (2004) · Otolaryngology · doi:10.1016/j.otohns.2004.02.048 · Cited by 125
Lifante, J., McGill, J. F., Murry, T., Aviv, J. E., & Inabnet, W. B. (2009) · Surgery · doi:10.1016/j.surg.2009.09.023 · Cited by 86
Evaluation of the Ultrasonic Dissector in Thyroid Surgery. A Prospective Randomised Study
Defêchereux, T., Rinken, F., Maweja, S., Hamoir, E., & Meurisse, M. (2003) · Acta chirurgica Belgica · doi:10.1080/00015458.2003.11679422 · Cited by 79 · cited 1×
“This may be attributable to optical magnification of the operative field, to the precise handing possible using a flexible endoscopic instrument, and to a decrease in stress on the paraesophageal space with the use of the Harmonic scalpel [26, 27].”
Akyıldız, S., Öğüt, F., Akyıldız, M., & Engın, E. Z. (2008) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.134.6.596 · Cited by 65
Cited by
Haugen, B. R., Alexander, E. K., Bible, K. C., Doherty, G. M., Mandel, S. J., Nikiforov, Y. E., Pacini, F., Randolph, G. W., Sawka, A. M., Schlumberger, M., et al. (2016) · Thyroid® · doi:10.1089/thy.2015.0020 · Cited by 16,535
Cooper, D. S., Doherty, G. M., Haugen, B. R., Kloos, R. T., Lee, S. L., Mandel, S. J., Mazzaferri, E. L., McIver, B., Pacini, F., Schlumberger, M., et al. (2009) · Thyroid · doi:10.1089/thy.2009.0110 · Cited by 6,707
New developments in the diagnosis and treatment of thyroid cancer
Schneider, D. F., & Chen, H. (2013) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21195 · Cited by 316
American Thyroid Association Statement on Remote-Access Thyroid Surgery
Berber, E., Bernet, V., Fahey, T. J., Kebebew, E., Shaha, A., Stack, B. C., Stang, M., Steward, D. L., Terris, D. J., & for the American Thyroid Association Surgical Affairs Committee (2016) · Thyroid · doi:10.1089/thy.2015.0407 · Cited by 246
“Postoperatively, the open cohort had significantly worse mean SIS-6 scores at both one week ( p = 0.001) and three months ( p = 0.007).”
MethodInfluentialThe History of Robotics in Surgical Specialties
Shah, J., Vyas, A., & Vyas, D. (2014) · American Journal of Robotic Surgery · doi:10.1166/ajrs.2014.1006 · Cited by 189
Metadata
- Authors
- Lee, J., Nah, K. Y., Kim, R. M., Ahn, Y. H., Soh, E.-Y., & Chung, W. Y.
- Venue
- Surgical Endoscopy
- Published
- 2010-05-19
- Volume
- 24
- Issue
- 12
- Pages
- 3186-3194
- ISSN
- 0930-2794 (ISSN-L)
- 1432-2218
- OpenAlex
- W2056083822
- Cited by
- 248
- References
- 14
- FWCI
- 20.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.