Bacterial clearance of biologic grafts used in hernia repair: an experimental study
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BackgroundBiologic grafts used in ventral hernia repair are derived from various sources and undergo different post-tissue-harvesting processing, handling, and sterilization techniques. It is unclear how these various characteristics impact graft response in the setting of contamination. We evaluated four materials in an infected hernia repair animal model using fluorescence imaging and quantitative culture studies.MethodsOne hundred seven rats underwent creation of a chronic hernia. They were then repaired with one synthetic polyester control material (n = 12) and four different biologic grafts (n = 24 per material). Biologic grafts evaluated included Surgisis (porcine small intestinal submucosa), Permacol (crosslinked porcine dermis), Xenmatrix (noncrosslinked porcine dermis), and Strattice (noncrosslinked porcine dermis). Half of the repairs in each group were inoculated with Staphylococcus aureus at 104 CFU/ml and survived for 30 days without systemic antibiotics. Animals then underwent fluorescence imaging and quantitative bacterial studies.ResultsAll clean repairs remained sterile. Rates of bacterial clearance were as follows: polyester synthetic 0%, Surgisis 58%, Permacol 67%, Xenmatrix 75%, and Strattice 92% (P = 0.003). Quantitative bacterial counts had a similar trend in bacterial clearance: polyester synthetic 1 × 106 CFU/g, Surgisis 4.3 × 105 CFU/g, Permacol 1.7 × 103 CFU/g, Xenmatrix 46 CFU/g, and Strattice 31 CFU/g (P = 0.001). Fluorescence imaging was unable to detect low bacterial fluorescence counts observed on bacterial studies.ConclusionBiologic grafts, in comparison to synthetic material, are able to clear a Staphylococcus aureus contamination; however, they are able to do so at different rates. Bacterial clearance correlated to the level of residual bacterial burden observed in our study. Post-tissue-harvesting processing, handling, and sterilization techniques may contribute to this observed difference in ability to clear bacteria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The extracellular matrix as a biologic scaffold material
Badylak, S. F. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.04.043 · Cited by 1,022
Cited by
The Pediatric Guidelines Sub-Committee for the World Society of the Abdominal Compartment Syndrome, Kirkpatrick, A. W., Roberts, D. J., De Waele, J., Jaeschke, R., Malbrain, M. L. N. G., De Keulenaer, B., Duchesne, J., Bjorck, M., Leppaniemi, A., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-013-2906-z · Cited by 1,624
Strategies for the management of adverse events associated with mTOR inhibitors
Kaplan, B., Qazi, Y., & Wellen, J. R. (2014) · Transplantation Reviews · doi:10.1016/j.trre.2014.03.002 · Cited by 322
Extracellular Matrix-Based Biomaterials and Their Influence Upon Cell Behavior
Cramer, M. C., & Badylak, S. F. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02408-9 · Cited by 196
Deeken, C. R., & Matthews, B. D. (2013) · ISRN Surgery · doi:10.1155/2013/238067 · Cited by 139
Cao, G., Huang, Y., Li, K., Fan, Y., Xie, H., & Li, X. (2019) · Journal of Materials Chemistry B · doi:10.1039/c9tb00530g · Cited by 101
Metadata
- Authors
- Harth, K. C., Broome, A.-M., Jacobs, M. R., Blatnik, J. A., Zeinali, F., Bajaksouzian, S., & Rosen, M. J.
- Venue
- Surgical Endoscopy
- Published
- 2011-02-07
- Volume
- 25
- Issue
- 7
- Pages
- 2224-2229
- ISSN
- 0930-2794 (ISSN-L)
- 1432-2218
- OpenAlex
- W2031280241
- Cited by
- 92
- References
- 1
- FWCI
- 12.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.