Attractive forces in microporous carbon electrodes for capacitive deionization
Open accessThe DOI matches its Crossref record; 73 of the 73 references it cites were found in a registry or an index.
Abstract
The recently developed modified Donnan (mD) model provides a simple and useful description of the electrical double layer in microporous carbon electrodes, suitable for incorporation in porous electrode theory. By postulating an attractive excess chemical potential for each ion in the micropores that is inversely proportional to the total ion concentration, we show that experimental data for capacitive deionization (CDI) can be accurately predicted over a wide range of applied voltages and salt concentrations. Since the ion spacing and Bjerrum length are each comparable to the micropore size (few nanometers), we postulate that the attraction results from fluctuating bare Coulomb interactions between individual ions and the metallic pore surfaces (image forces) that are not captured by mean-field theories, such as the Poisson-Boltzmann-Stern model or its mathematical limit for overlapping double layers, the Donnan model. Using reasonable estimates of the micropore permittivity and mean size (and no other fitting parameters), we propose a simple theory that predicts the attractive chemical potential inferred from experiments. As additional evidence for attractive forces, we present data for salt adsorption in uncharged microporous carbons, also predicted by the theory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2020) · Electromagnetic Processes · doi:10.2307/j.ctv131bv37.5 · Cited by 21,966
The Electrical Double Layer and the Theory of Electrocapillarity.
Grahame, D. C. (1947) · Chemical Reviews · doi:10.1021/cr60130a002 · Cited by 3,323
Review on the science and technology of water desalination by capacitive deionization
Porada, S., Zhao, R., van der Wal, A., Presser, V., & Biesheuvel, P. M. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.03.005 · Cited by 2,152
Self-citationDouble Layer in Ionic Liquids: Overscreening versus Crowding
Bazant, M. Z., Storey, B. D., & Kornyshev, A. A. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.046102 · Cited by 1,098
Self-citationColloquium: The physics of charge inversion in chemical and biological systems
Grosberg, A. Y., Nguyen, T. T., & Shklovskii, B. I. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.329 · Cited by 1,082
Free-energy density functional for hard spheres
Tarazona, P. (1985) · Physical Review A · doi:10.1103/physreva.31.2672 · Cited by 1,065
Diffuse-charge dynamics in electrochemical systems
Bazant, M. Z., Thornton, K., & Ajdari, A. (2004) · Physical Review E · doi:10.1103/physreve.70.021506 · Cited by 1,053
Self-citationDesalination via a New Membrane Capacitive Deionization Process Utilizing Flow-Electrodes
Jeon, S.-I., Park, H.-R., Yeo, J.-G., Yang, S., Cho, C. H., Han, M. H., & Kim, D. K. (2013) · Energy & Environmental Science · doi:10.1039/c3ee24443a · Cited by 727
Treatment of brackish produced water using carbon aerogel-based capacitive deionization technology
Xu, P., Drewes, J. E., Heil, D., & Wang, G. (2008) · Water Research · doi:10.1016/j.watres.2008.01.011 · Cited by 599
Porada, S., Borchardt, L., Oschatz, M., Bryjak, M., Atchison, J. S., Keesman, K. J., Kaskel, S., Biesheuvel, P. M., & Presser, V. (2013) · Energy & Environmental Science · doi:10.1039/c3ee42209g · Cited by 571
Self-citation
Cited by
Water desalination via capacitive deionization: what is it and what can we expect from it?
Suss, M. E., Porada, S., Sun, X., Biesheuvel, P. M., Yoon, J., & Presser, V. (2015) · Energy & Environmental Science · doi:10.1039/c5ee00519a · Cited by 1,712
Self-citationElectrochemical Methods for Water Purification, Ion Separations, and Energy Conversion
Alkhadra, M. A., Su, X., Suss, M. E., Tian, H., Guyes, E. N., Shocron, A. N., Conforti, K. M., de Souza, J. P., Kim, N., Tedesco, M., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00396 · Cited by 661
Self-citationRecent advances in ion selectivity with capacitive deionization
Gamaethiralalage, J. G., Singh, K., Sahin, S., Yoon, J., Elimelech, M., Suss, M. E., Liang, P., Biesheuvel, P. M., Zornitta, R. L., & de Smet, L. C. P. M. (2021) · Energy & Environmental Science · doi:10.1039/d0ee03145c · Cited by 506
Self-citationVarious cell architectures of capacitive deionization: Recent advances and future trends
Tang, W., Liang, J., He, D., Gong, J., Tang, L., Liu, Z., Wang, D., & Zeng, G. (2019) · Water Research · doi:10.1016/j.watres.2018.11.064 · Cited by 461
Gao, X., Omosebi, A., Landon, J., & Liu, K. (2015) · Energy & Environmental Science · doi:10.1039/c4ee03172e · Cited by 412
Review on carbon-based composite materials for capacitive deionization
Liu, Y., Nie, C., Liu, X., Xu, X., Sun, Z., & Pan, L. (2015) · RSC Advances · doi:10.1039/c4ra14447c · Cited by 393
Continuous transition from double-layer to Faradaic charge storage in confined electrolytes
Fleischmann, S., Zhang, Y., Wang, X., Cummings, P. T., Wu, J., Simon, P., Gogotsi, Y., Presser, V., & Augustyn, V. (2022) · Nature Energy · doi:10.1038/s41560-022-00993-z · Cited by 338
Versatile applications of capacitive deionization (CDI)-based technologies
Xing, W., Liang, J., Tang, W., He, D., Yan, M., Wang, X., Luo, Y., Tang, N., & Huang, M. (2020) · Desalination · doi:10.1016/j.desal.2020.114390 · Cited by 318
Graphene-based materials for capacitive deionization
Liu, P., Yan, T., Shi, L., Park, H. S., Chen, X., Zhao, Z., & Zhang, D. (2017) · Journal of Materials Chemistry A · doi:10.1039/c7ta02653f · Cited by 311
Prehal, C., Koczwara, C., Jäckel, N., Schreiber, A., Burian, M., Amenitsch, H., Hartmann, M. A., Presser, V., & Paris, O. (2017) · Nature Energy · doi:10.1038/nenergy.2016.215 · Cited by 310
Porada, S., Weingarth, D., Hamelers, H. V. M., Bryjak, M., Presser, V., & Biesheuvel, P. M. (2014) · Journal of Materials Chemistry A · doi:10.1039/c4ta01783h · Cited by 308
Self-citationMicroscopic Simulations of Electrochemical Double-Layer Capacitors
Jeanmairet, G., Rotenberg, B., & Salanne, M. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00925 · Cited by 303
Carbon electrodes for capacitive technologies
Ratajczak, P., Suss, M. E., Kaasik, F., & Béguin, F. (2019) · Energy Storage Materials · doi:10.1016/j.ensm.2018.04.031 · Cited by 297
Faradaic Electrodes Open a New Era for Capacitive Deionization
Li, Q., Zheng, Y., Xiao, D., Or, T., Gao, R., Li, Z., Feng, M., Shui, L., Zhou, G., Wang, X., et al. (2020) · Advanced Science · doi:10.1002/advs.202002213 · Cited by 288
Performance metrics for the objective assessment of capacitive deionization systems
Hawks, S. A., Ramachandran, A., Porada, S., Campbell, P. G., Suss, M. E., Biesheuvel, P. M., Santiago, J. G., & Stadermann, M. (2019) · Water Research · doi:10.1016/j.watres.2018.10.074 · Cited by 279
Self-citationLi, Y., Liu, Y., Wang, M., Xu, X., Lu, T., Sun, C. Q., & Pan, L. (2018) · Carbon · doi:10.1016/j.carbon.2018.01.035 · Cited by 272
CDI ragone plot as a functional tool to evaluate desalination performance in capacitive deionization
Kim, T., & Yoon, J. (2015) · RSC Advances · doi:10.1039/c4ra11257a · Cited by 269
Kim, T., Dykstra, J. E., Porada, S., van der Wal, A., Yoon, J., & Biesheuvel, P. M. (2015) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2014.08.041 · Cited by 235
Self-citationFluoride and nitrate removal from brackish groundwaters by batch-mode capacitive deionization
Tang, W., Kovalsky, P., He, D., & Waite, T. D. (2015) · Water Research · doi:10.1016/j.watres.2015.08.012 · Cited by 231
Exceptional capacitive deionization rate and capacity by block copolymer–based porous carbon fibers
Liu, T., Serrano, J., Elliott, J., Yang, X., Cathcart, W., Wang, Z., He, Z., & Liu, G. (2020) · Science Advances · doi:10.1126/sciadv.aaz0906 · Cited by 218
Srimuk, P., Lee, J., Fleischmann, S., Choudhury, S., Jäckel, N., Zeiger, M., Kim, C., Aslan, M., & Presser, V. (2017) · Journal of Materials Chemistry A · doi:10.1039/c7ta03120c · Cited by 202
Resistance identification and rational process design in Capacitive Deionization
Dykstra, J. E., Zhao, R., Biesheuvel, P. M., & van der Wal, A. (2016) · Water Research · doi:10.1016/j.watres.2015.10.006 · Cited by 182
Self-citationPrehal, C., Weingarth, D., Perre, E., Lechner, R. T., Amenitsch, H., Paris, O., & Presser, V. (2015) · Energy & Environmental Science · doi:10.1039/c5ee00488h · Cited by 173
Heat-to-current conversion of low-grade heat from a thermocapacitive cycle by supercapacitors
Härtel, A., Janssen, M., Weingarth, D., Presser, V., & van Roij, R. (2015) · Energy & Environmental Science · doi:10.1039/c5ee01192b · Cited by 159
Metadata
- Authors
- Biesheuvel, P. M., Porada, S., Levi, M., & Bazant, M. Z.
- Venue
- Journal of Solid State Electrochemistry
- Published
- 2014-02-01
- Volume
- 18
- Issue
- 5
- Pages
- 1365-1376
- ISSN
- 1432-8488 (ISSN-L)
- 1433-0768
- OpenAlex
- W2127067919
- Cited by
- 304
- References
- 73
- FWCI
- 15.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.