The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
CDI ragone plot as a functional tool to evaluate desalination performance in capacitive deionization
Abstract
A novel concept to evaluate desalination performance in capacitive deionization (CDI) is proposed called the CDI Ragone plot.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,435
Materials for electrochemical capacitors
Simon, P., & Gogotsi, Y. (2008) · Nature Materials · doi:10.1038/nmat2297 · Cited by 16,427
Review on the science and technology of water desalination by capacitive deionization
Porada, S., Zhao, R., van der Wal, A., Presser, V., & Biesheuvel, P. M. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.03.005 · Cited by 2,152
Oren, Y. (2008) · Desalination · doi:10.1016/j.desal.2007.08.005 · Cited by 1,180
Anderson, M. A., Cudero, A. L., & Palma, J. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2010.02.012 · Cited by 943
Desalination via a New Membrane Capacitive Deionization Process Utilizing Flow-Electrodes
Jeon, S.-I., Park, H.-R., Yeo, J.-G., Yang, S., Cho, C. H., Han, M. H., & Kim, D. K. (2013) · Energy & Environmental Science · doi:10.1039/c3ee24443a · Cited by 727
Hybrid capacitive deionization to enhance the desalination performance of capacitive techniques
Lee, J., Kim, S., Kim, C., & Yoon, J. (2014) · Energy Environ. Sci. · doi:10.1039/c4ee02378a · Cited by 676
Self-citationPorada, S., Borchardt, L., Oschatz, M., Bryjak, M., Atchison, J. S., Keesman, K. J., Kaskel, S., Biesheuvel, P. M., & Presser, V. (2013) · Energy & Environmental Science · doi:10.1039/c3ee42209g · Cited by 571
Yin, H., Zhao, S., Wan, J., Tang, H., Chang, L., He, L., Zhao, H., Gao, Y., & Tang, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302223 · Cited by 545
Desalination of a thermal power plant wastewater by membrane capacitive deionization
Lee, J.-B., Park, K.-K., Eum, H.-M., & Lee, C.-W. (2006) · Desalination · doi:10.1016/j.desal.2006.01.011 · Cited by 525
Cited by
Srimuk, P., Su, X., Yoon, J., Aurbach, D., & Presser, V. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0193-1 · Cited by 665
Self-citationKim, M., Xu, X., Xin, R., Earnshaw, J., Ashok, A., Kim, J., Park, T., Nanjundan, A. K., El-Said, W. A., Yi, J. W., et al. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c09107 · Cited by 268
Shaikh, N. S., Ubale, S. B., Mane, V. J., Shaikh, J. S., Lokhande, V. C., Praserthdam, S., Lokhande, C. D., & Kanjanaboos, P. (2022) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2021.161998 · Cited by 253
Qu, Y., Campbell, P. G., Gu, L., Knipe, J. M., Dzenitis, E., Santiago, J. G., & Stadermann, M. (2016) · Desalination · doi:10.1016/j.desal.2016.09.014 · Cited by 159
Review of Concepts and Applications of Electrochemical Ion Separation (EIONS) Process
Yoon, H., Lee, J., Kim, S., & Yoon, J. (2019) · Separation and Purification Technology · doi:10.1016/j.seppur.2018.12.071 · Cited by 133
Metadata
- Authors
- Kim, T., & Yoon, J.
- Venue
- RSC Advances
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 5
- Issue
- 2
- Pages
- 1456-1461
- ISSN
- 2046-2069 (ISSN-L)
- OpenAlex
- W2071666687
- Cited by
- 269
- References
- 34
- FWCI
- 7.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CDI ragone plot as a functional tool to evaluate desalination performance in capacitive deionization. https://app.cochat.ai/papers/10.1039/c4ra11257a
- The paper
- Kim, T., & Yoon, J. (2015). CDI ragone plot as a functional tool to evaluate desalination performance in capacitive deionization. RSC Advances. https://doi.org/10.1039/c4ra11257a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.