Use of porcine small intestinal submucosa as a prosthetic device for laparoscopic repair of hernias in contaminated fields: 2-year follow-up
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Small intestinal submucosa as a large diameter vascular graft in the dog
Badylak, S. F., Lantz, G. C., Coffey, A., & Geddes, L. A. (1989) · Journal of Surgical Research · doi:10.1016/0022-4804(89)90050-4 · Cited by 613 · cited 1×
“It is a naturally occurring extracellular matrix, which is easily absorbed, supports early and abundant new vessel growth, and appears to foster cellular differentiation [4, 5, 6, 7].”
BackgroundIntestine Submucosa and Polypropylene Mesh for Abdominal Wall Repair in Dogs
Clarke, K. M., Lantz, G. C., Salisbury, S. K., Badylak, S. F., Hiles, M. C., & Voytik, S. L. (1996) · Journal of Surgical Research · doi:10.1006/jsre.1996.0018 · Cited by 259 · cited 1×
“scaffold for host-tissue ingrowth and remodeling [13].”
Strength over Time of a Resorbable Bioscaffold for Body Wall Repair in a Dog Model
Badylak, S., Kokini, K., Tullius, B., & Whitson, B. (2001) · Journal of Surgical Research · doi:10.1006/jsre.2001.6176 · Cited by 232 · cited 1×
“were able to compare burst strengths of the normal canine abdominal wall, the SIS mesh prior to implantation, and the SIS after implantation [12].”
MethodSmall Intestinal Submucosa as a Small-Diameter Arterial Graft in the Dog
Lantz, G. C., Badylak, S. F., Coffey, A. C., Geddes, L. A., & Blevins, W. E. (1990) · Journal of Investigative Surgery · doi:10.3109/08941939009140351 · Cited by 210 · cited 1×
“It is a naturally occurring extracellular matrix, which is easily absorbed, supports early and abundant new vessel growth, and appears to foster cellular differentiation [4, 5, 6, 7].”
BackgroundSandusky, G. E., Badylak, S. F., Morff, R. J., Johnson, W. D., & Lantz, G. C. (1992) · PubMed Central · Cited by 177
Badylak, S. F., Coffey, A. C., Lantz, G. C., Tacker, W. A., & Geddes, L. A. (1994) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(94)70073-7 · Cited by 159 · cited 1×
“Badylak and colleagues deliberately challenged SIS and expanded polytetrafluoroethylene (ePTFE) infrarenal aortic grafts with Staphylococcus aureus [9].”
BackgroundFranklin, M. E., Gonzalez, J., Michaelson, R., Glass, J. L., & Chock, D. (2002) · Hernia · doi:10.1007/s10029-002-0078-9 · Cited by 155 · cited 1×
“In our preliminary study with short-term follow-up, we demonstrated that SIS appeared to be a viable alternative for placement of mesh in contaminated fields with respect to resistance to infection and maintenance of tensile strength [10].”
BackgroundInfluentialSelf-citationSmall intestinal submucosa as a superior vena cava graft in the dog
Lantz, G. C., Badylak, S. F., Coffey, A. C., Geddes, L. A., & Sandusky, G. E. (1992) · Journal of Surgical Research · doi:10.1016/0022-4804(92)90031-t · Cited by 152 · cited 1×
“It is a naturally occurring extracellular matrix, which is easily absorbed, supports early and abundant new vessel growth, and appears to foster cellular differentiation [4, 5, 6, 7].”
BackgroundSmall Intestinal Submucosa: Utilization as a Wound Dressing in Full-Thickness Rodent Wounds
Prevel, C. D., Eppley, B. L., Summerlin, D.-J., Sidner, R., Jackson, J. R., McCarty, M., & Badylak, S. F. (1995) · Annals of Plastic Surgery · doi:10.1097/00000637-199510000-00009 · Cited by 135 · cited 1×
“In a full-thickness, rat-skin replacement study, no acute or delayed hypersensitivity reactions were observed [8].”
Background
Cited by
Collagen—emerging collagen based therapies hit the patient
Abou Neel, E. A., Bozec, L., Knowles, J. C., Syed, O., Mudera, V., Day, R., & Hyun, J. K. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.08.010 · Cited by 296
“SIS has been used in the repair of multiple types of hernia [86] and the rotator cuff tendon of the shoulder joint [87,88].”
Method2017 update of the WSES guidelines for emergency repair of complicated abdominal wall hernias
Birindelli, A., Sartelli, M., Di Saverio, S., Coccolini, F., Ansaloni, L., van Ramshorst, G. H., Campanelli, G., Khokha, V., Moore, E. E., Peitzman, A., et al. (2017) · World Journal of Emergency Surgery · doi:10.1186/s13017-017-0149-y · Cited by 232
ECM hydrogel coating mitigates the chronic inflammatory response to polypropylene mesh
Faulk, D. M., Londono, R., Wolf, M. T., Ranallo, C. A., Carruthers, C. A., Wildemann, J. D., Dearth, C. L., & Badylak, S. F. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.06.057 · Cited by 183
Franklin, M. E., Treviño, J. M., Portillo, G., Vela, I., Glass, J. L., & González, J. J. (2008) · Surgical Endoscopy · doi:10.1007/s00464-008-0005-y · Cited by 173
“In our preliminary study with short-term follow-up and our last study with 2-year follow-up, we demonstrated that SIS appears to be a viable alternative for mesh placement in contaminated fields where the tensile strength of a nonabsorbable mesh is desired and the infection resistance of an absorbable implant is requi…”
BackgroundMethodSelf-citationAre Biologic Grafts Effective for Hernia Repair?: A Systematic Review of the Literature
Hiles, M., Record Ritchie, R. D., & Altizer, A. M. (2009) · Surgical Innovation · doi:10.1177/1553350609331397 · Cited by 172
Metadata
- Authors
- Franklin, M. E., Gonzalez, J. J., & Glass, J. L.
- Venue
- Hernia
- Published
- 2004-02-26
- Volume
- 8
- Issue
- 3
- Pages
- 186-189
- ISSN
- 1248-9204 (ISSN-L)
- 1265-4906
- OpenAlex
- W2055768608
- Cited by
- 174
- References
- 9
- FWCI
- 13.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of porcine small intestinal submucosa as a prosthetic device for laparoscopic repair of hernias in contaminated fields: 2-year follow-up. https://app.cochat.ai/papers/10.1007/s10029-004-0208-7
- The paper
- Franklin, M. E., Gonzalez, J. J., & Glass, J. L. (2004). Use of porcine small intestinal submucosa as a prosthetic device for laparoscopic repair of hernias in contaminated fields: 2-year follow-up. Hernia. https://doi.org/10.1007/s10029-004-0208-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.