The DOI matches its Crossref record.
Small Intestinal Submucosa as a Small-Diameter Arterial Graft in the Dog
Abstract
Autogenous saphenous vein, human umbilical vein, modified bovine collagen, Dacron, and PTFE have been used as small-diameter arterial grafts with moderate success. We tested autogenous small intestine submucosa as a small-diameter arterial graft in both a carotid and femoral artery (mean ID 4.3 mm) of 18 dogs (total of 36 grafts). All dogs received aspirin and warfarin sodium for the first 8 weeks after surgery. Graft patency was evaluated by Doppler ultrasound techniques and angiography. Two grafts ruptured and 5 grafts occluded by 21 days after surgery. One graft became occluded at 14 weeks. Fifteen dogs were sacrificed at periodic intervals until 48 weeks after surgery. Patent grafts had no evidence of infection, propagating thrombus, or intimal hyperplasia. Graft aneurysmal dilation occurred in 4 grafts (11%). The grafts were composed of a dense organized collagenous connective tissue with no evidence of endothelial cell growth on the smooth luminal surface. Three dogs are alive at 76 to 82 weeks after surgery. Overall, graft patency was 75%. Graft patency after cessation of anticoagulation therapy was 92.3% (12 of 13 grafts). We conclude that autogenous small intestinal submucosa can be used as a small-diameter arterial graft in the dog and is worthy of further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Acellular vascular tissues: natural biomaterials for tissue repair and tissue engineering
Schmidt, C. E., & Baier, J. M. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00148-4 · Cited by 762
Xenogeneic extracellular matrix as a scaffold for tissue reconstruction
Badylak, S. F. (2004) · Transplant Immunology · doi:10.1016/j.trim.2003.12.016 · Cited by 747
Self-citationZheng, M. H., Chen, J., Kirilak, Y., Willers, C., Xu, J., & Wood, D. (2005) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30170 · Cited by 441
Badylak, S. F. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0963-7 · Cited by 307
Self-citationCollagen—emerging collagen based therapies hit the patient
Abou Neel, E. A., Bozec, L., Knowles, J. C., Syed, O., Mudera, V., Day, R., & Hyun, J. K. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.08.010 · Cited by 296
Metadata
- Authors
- Lantz, G. C., Badylak, S. F., Coffey, A. C., Geddes, L. A., & Blevins, W. E.
- Venue
- Journal of Investigative Surgery
- Publisher
- Informa UK Limited
- Published
- 1990-01
- Volume
- 3
- Issue
- 3
- Pages
- 217-227
- ISSN
- 0894-1939 (ISSN-L)
- 1521-0553
- OpenAlex
- W2032876761
- Cited by
- 210
- References
- 0
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Small Intestinal Submucosa as a Small-Diameter Arterial Graft in the Dog. https://app.cochat.ai/papers/10.3109/08941939009140351
- The paper
- Lantz, G. C., Badylak, S. F., Coffey, A. C., Geddes, L. A., & Blevins, W. E. (1990). Small Intestinal Submucosa as a Small-Diameter Arterial Graft in the Dog. Journal of Investigative Surgery. https://doi.org/10.3109/08941939009140351
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.