Early biocompatibility of crosslinked and non-crosslinked biologic meshes in a porcine model of ventral hernia repair
Open accessThe DOI matches its Crossref record.
Abstract
PurposeBiologic meshes have unique physical properties as a result of manufacturing techniques such as decellularization, crosslinking, and sterilization. The purpose of this study is to directly compare the biocompatibility profiles of five different biologic meshes, AlloDerm® (non-crosslinked human dermal matrix), PeriGuard® (crosslinked bovine pericardium), Permacol® (crosslinked porcine dermal matrix), Strattice® (non-crosslinked porcine dermal matrix), and Veritas® (non-crosslinked bovine pericardium), using a porcine model of ventral hernia repair.MethodsFull-thickness fascial defects were created in 20 Yucatan minipigs and repaired with the retromuscular placement of biologic mesh 3 weeks later. Animals were euthanized at 1 month and the repair sites were subjected to tensile testing and histologic analysis. Samples of unimplanted (de novo) meshes and native porcine abdominal wall were also analyzed for their mechanical properties.ResultsThere were no significant differences in the biomechanical characteristics between any of the mesh-repaired sites at 1 month postimplantation or between the native porcine abdominal wall without implanted mesh and the mesh-repaired sites (P > 0.05 for all comparisons). Histologically, non-crosslinked materials exhibited greater cellular infiltration, extracellular matrix (ECM) deposition, and neovascularization compared to crosslinked meshes.ConclusionsWhile crosslinking differentiates biologic meshes with regard to cellular infiltration, ECM deposition, scaffold degradation, and neovascularization, the integrity and strength of the repair site at 1 month is not significantly impacted by crosslinking or by the de novo strength/stiffness of the mesh.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brown, B. N., Londono, R., Tottey, S., Zhang, L., Kukla, K. A., Wolf, M. T., Daly, K. A., Reing, J. E., & Badylak, S. F. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.11.031 · Cited by 745
Future Prospects for Scaffolding Methods and Biomaterials in Skin Tissue Engineering: A Review
Chaudhari, A., Vig, K., Baganizi, D., Sahu, R., Dixit, S., Dennis, V., Singh, S., & Pillai, S. (2016) · International Journal of Molecular Sciences · doi:10.3390/ijms17121974 · Cited by 604
Delgado, L. M., Bayon, Y., Pandit, A., & Zeugolis, D. I. (2015) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2014.0290 · Cited by 272
Macroscale biomaterials strategies for local immunomodulation
Dellacherie, M. O., Seo, B. R., & Mooney, D. J. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0106-3 · Cited by 255
Dermal Matrices and Bioengineered Skin Substitutes: A Critical Review of Current Options
Debels, H., Hamdi, M., Abberton, K., & Morrison, W. (2015) · Plastic and Reconstructive Surgery Global Open · doi:10.1097/gox.0000000000000219 · Cited by 227
Metadata
- Authors
- Melman, L., Jenkins, E. D., Hamilton, N. A., Bender, L. C., Brodt, M. D., Deeken, C. R., Greco, S. C., Frisella, M. M., & Matthews, B. D.
- Venue
- Hernia
- Published
- 2011-01-08
- Volume
- 15
- Issue
- 2
- Pages
- 157-164
- ISSN
- 1248-9204 (ISSN-L)
- 1265-4906
- OpenAlex
- W1989227316
- Cited by
- 127
- References
- 0
- FWCI
- 12.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Early biocompatibility of crosslinked and non-crosslinked biologic meshes in a porcine model of ventral hernia repair. https://app.cochat.ai/papers/10.1007/s10029-010-0770-0
- The paper
- Melman, L., Jenkins, E. D., Hamilton, N. A., Bender, L. C., Brodt, M. D., Deeken, C. R., Greco, S. C., Frisella, M. M., & Matthews, B. D. (2011). Early biocompatibility of crosslinked and non-crosslinked biologic meshes in a porcine model of ventral hernia repair. Hernia. https://doi.org/10.1007/s10029-010-0770-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.