The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Review of methodological developments in laser Doppler flowmetry
Open accessAbstract
Laser Doppler flowmetry is a non-invasive method of measuring microcirculatory blood flow in tissue. In this review the technique is discussed in detail. The theoretical and experimental developments to improve the technique are reviewed. The limitations of the method are elaborated upon, and the research done so far to overcome these limitations is critically assessed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Blood flow measurements with radionuclide-labeled particles
Heymann, M. A., Payne, B. D., Hoffman, J. I. E., & Rudolph, A. M. (1977) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(77)80005-4 · Cited by 2,036
RUDOLPH, A. M., & HEYMANN, M. A. (1967) · Circulation Research · doi:10.1161/01.res.21.2.163 · Cited by 1,316
Evaluation of a Laser Doppler Flowmeter for Measurement of Tissue Blood Flow
Nilsson, G. E., Tenland, T., & Oberg, P. A. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326582 · Cited by 1,095
In vivo evaluation of microcirculation by coherent light scattering
STERN, M. D. (1975) · Nature · doi:10.1038/254056a0 · Cited by 857
Model for laser Doppler measurements of blood flow in tissue
Bonner, R., & Nossal, R. (1981) · Applied Optics · doi:10.1364/ao.20.002097 · Cited by 836
Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging
Briers, J. D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/201 · Cited by 686
Zhao, Y., Chen, Z., Saxer, C., Xiang, S., de Boer, J. F., & Nelson, J. S. (2000) · Optics Letters · doi:10.1364/ol.25.000114 · Cited by 559
LASER DOPPLER MEASUREMENT OF CUTANEOUS BLOOD FLOW
Holloway, G. A., & Watkins, D. W. (1977) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12507665 · Cited by 538
Laser Doppler perfusion imaging by dynamic light scattering
Wardell, K., Jakobsson, A., & Nilsson, G. E. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.222322 · Cited by 435
Blood Flow through Human Adipose Tissue Determined with Radioactive Xenon
Larsen, O. A., Lassen, N. A., & Quaade, F. (1966) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1966.tb03208.x · Cited by 337
Cited by
Molecular Imaging of Ovarian Follicles and Tumors With Near‐Infrared II Bioconjugates
Wang, Y., Lu, W., Chen, Z., Xiao, Y., Wang, Y., Gao, W., Wang, Z., Song, R., Fang, Z., Hu, W., et al. (2025) · Advanced Materials · doi:10.1002/adma.202414129 · Cited by 17
Metadata
- Authors
- Rajan, V., Varghese, B., van Leeuwen, T. G., & Steenbergen, W.
- Venue
- Lasers in Medical Science
- Published
- 2008-01-31
- Volume
- 24
- Issue
- 2
- Pages
- 269-283
- ISSN
- 0268-8921 (ISSN-L)
- 1435-604X
- OpenAlex
- W2163861966
- Cited by
- 313
- References
- 32
- FWCI
- 6.45
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review of methodological developments in laser Doppler flowmetry. https://app.cochat.ai/papers/10.1007/s10103-007-0524-0
- The paper
- Rajan, V., Varghese, B., van Leeuwen, T. G., & Steenbergen, W. (2009). Review of methodological developments in laser Doppler flowmetry. Lasers in Medical Science. https://doi.org/10.1007/s10103-007-0524-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.