Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 435

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Laser Doppler perfusion imaging by dynamic light scattering

Wardell, K., Jakobsson, A., Nilsson, G.E.·1993·IEEE Transactions on Biomedical Engineering

Abstract

Imaging of tissue perfusion is important in assessing the influence of peripheral vascular disease on microcirculation. This paper reports on a laser Doppler perfusion imaging technique based on dynamic light scattering in tissue. When a laser beam sequentially scans the tissue (maximal area approximately 12 cm *12 cm), moving blood cells generate Doppler components in the back-scattered light. A fraction of this light is detected by a remote photodiode and converted into an electrical signal. In the signal processor, a signal proportional to the tissue perfusion at each measurement point is calculated and stored. When the scanning procedure is completed, the system generates a color-coded perfusion image on a monitor. A perfusion image is typically built up of data from 4,096 measurement sites, recorded during a time period of 4 min. This image has a spatial resolution of about 2 mm * 2 mm. A theory for the system inherent amplification factor dependence on the distance between individual measurement points and detector is proposed and correction measures are presented. The performance of the laser Doppler perfusion imager was evaluated using a flow simulator. The correlation coefficient between the estimated flow parameter and the perfusion through a mechanical flow simulator was calculated to r = 0.996. To assess the sampling depth of the laser beam, light scattering in tissue was simulated by a Monte Carlo technique. The average sampling depth for skin tissue was calculated to 200-240 microns, depending on the blood content.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.222322

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 435

Metadata

Authors
Wardell, K., Jakobsson, A., & Nilsson, G. E.
Venue
IEEE Transactions on Biomedical Engineering
Published
1993-04
Volume
40
Issue
4
Pages
309-316
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2109824025
Cited by
435
References
14
FWCI
10.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Laser Doppler perfusion imaging by dynamic light scattering. https://app.cochat.ai/papers/10.1109/10.222322
The paper
Wardell, K., Jakobsson, A., & Nilsson, G. E. (1993). Laser Doppler perfusion imaging by dynamic light scattering. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.222322

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.