Cited by 3Reconstructive Facial Surgery TechniquesNasal Surgery and Airway StudiesDermatologic Treatments and Research

Continuous cooling system in conjunction with laser surgery for ear reshaping.

Hsiao, Yen-Chang, Ting, Kuen, Su, Yun-Liang, Chang, Cheng-Jen·2020·Lasers in Medical Science

Abstract

When the cartilage on the prominent ears is reshaped, the arising stress returns the tissue to its initial configuration. Laser irradiation of areas of maximal stress leads to stress relaxation and results in a stable configuration. Sixty auricles were harvested from 30 New Zealand white rabbits and cut into a rectangle measuring 50 mm by 25 mm with an average thickness of approximately 1.3 mm. Bilateral skin was included for ex vivo studies. Continuous cryogen spray cooling (CSC) with laser energy was delivered to the exposed cartilage for reshaping. In clinical applications, from January 2006 to December 2016, a total of 50 patients with 100 bat ears who underwent CO 2 laser reshaping (otoplasty) were assessed. A continuous cooling system (4 °C) in conjunction with a CO 2 laser was applied to make a retroauricular-approached incision and reshape the ear cartilage. The well cartilage bending correlated with the different parameters demonstrated in the continuous CSC protected group. All 100 (100%) of the subjects experienced early complications (≤ 1 month) related to laser exposure with swelling, while 5 (5%) experienced ecchymosis, 2 (2%) minimal hematoma, 2 (2%) scarring, 1 (1%) minor infection, 1 (1%) under correction, 1 (1%) overcorrection, and 1 (1%) relapse. These problems were corrected and/or had resolved after 3 months. All patients achieved good to excellent results in our final outcome assessment (> 6 months). Laser reshaping has a potential use in certain surgical procedures involving the cartilage. The appropriate conditions for laser ear reshaping clearly depend on the laser wavelength used, energy controlling, and tissue optical properties.

Integrity signals

Registry

Crossref · 10.1007/s10103-019-02831-3

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Hsiao, Y.-C., Ting, K., Su, Y.-L., & Chang, C.-J.
Affiliations
  • Chang Gung University (TW)
  • Lunghwa University of Science and Technology (TW)
  • National Chung Hsing University (TW)
Corresponding author
Chang, Cheng-Jen
Venue
Lasers in Medical Science
Published
2019-07-01
Volume
35
Issue
2
Pages
387-393
ISSN
  • 0268-8921 (ISSN-L)
  • 1435-604X
OpenAlex
W2954842577
Cited by
3
References
36
Citations by year
2026: 1 · 2023: 1 · 2021: 1
FWCI
0.24
Type
journal article
Language
en
Open access
closed
Locations
  • Lasers in Medical Science (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Reconstructive Facial Surgery Techniques
  • Health Sciences › Medicine › Surgery › Nasal Surgery and Airway Studies
  • Health Sciences › Medicine › Dermatology › Dermatologic Treatments and Research
Keywords
otoplasty, prominent ears, CO2 laser, stress relaxation, auricle, postoperative complications
MeSH terms
Adolescent, Adult, Animals, Cicatrix, Cold Temperature, Ear, Ear Cartilage, Female, Humans, Longitudinal Studies, Male, Rabbits, Skin, Plastic Surgery Procedures, Laser Therapy, Lasers, Gas, Ear Auricle, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review