Usefulness of presepsin (sCD14-ST) measurements as a marker for the diagnosis and severity of sepsis that satisfied diagnostic criteria of systemic inflammatory response syndrome
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
APACHE II: A severity of disease classification system
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Critical Care Medicine · doi:10.1097/00003246-198510000-00009 · Cited by 13,664
APACHE II-A Severity of Disease Classification System: Reply
Knaus, W. A., Draper, E. A., Wagner, D. P., & Zimmerman, J. E. (1986) · Critical Care Medicine · doi:10.1097/00003246-198608000-00028 · Cited by 13,376
Evaluation of a newly identified soluble CD14 subtype as a marker for sepsis
Yaegashi, Y., Sato, N., Suzuki, Y., Kojika, M., Imai, S., Takahashi, G., Miyata, M., Endo, S., Shirakawa, K., & Furusako, S. (2005) · Journal of Infection and Chemotherapy · doi:10.1007/s10156-005-0400-4 · Cited by 319
Self-citationEvaluation of cardiac assays on a benchtop chemiluminescent enzyme immunoassay analyzer, PATHFAST
Kurihara, T., Yanagida, A., Yokoi, H., Koyata, A., Matsuya, T., Ogawa, J., Okamura, Y., & Miyamoto, D. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2007.12.030 · Cited by 52
Self-citation
Cited by
The Pathogenesis of Sepsis and Potential Therapeutic Targets
Huang, M., Cai, S., & Su, J. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20215376 · Cited by 776
Faix, J. D. (2013) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2013.764490 · Cited by 663
Usefulness of presepsin in the diagnosis of sepsis in a multicenter prospective study
Endo, S., Suzuki, Y., Takahashi, G., Shozushima, T., Ishikura, H., Murai, A., Nishida, T., Irie, Y., Miura, M., Iguchi, H., et al. (2012) · Journal of Infection and Chemotherapy · doi:10.1007/s10156-012-0435-2 · Cited by 311
Self-citationDiagnostic value and prognostic evaluation of Presepsin for sepsis in an emergency department
Liu, B., Chen, Y.-X., Yin, Q., Zhao, Y.-Z., & Li, C.-S. (2013) · Critical Care · doi:10.1186/cc13070 · Cited by 299
2023 Update on Sepsis and Septic Shock in Adult Patients: Management in the Emergency Department
Guarino, M., Perna, B., Cesaro, A. E., Maritati, M., Spampinato, M. D., Contini, C., & De Giorgio, R. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12093188 · Cited by 294
Ulla, M., Pizzolato, E., Lucchiari, M., Loiacono, M., Soardo, F., Forno, D., Morello, F., Lupia, E., Moiraghi, C., Mengozzi, G., et al. (2013) · Critical Care · doi:10.1186/cc12847 · Cited by 260
Masson, S., Caironi, P., Spanuth, E., Thomae, R., Panigada, M., Sangiorgi, G., Fumagalli, R., Mauri, T., Isgrò, S., Fanizza, C., et al. (2014) · Critical Care · doi:10.1186/cc13183 · Cited by 240
“Presepsin (sCD14-ST) is a soluble N-terminal fragment of the cluster of differentiation (CD) marker protein CD14, which is released into the circulation during monocyte activation upon the recognition of lipopolysaccharide (LPS) from infectious agents [6].”
BackgroundBehnes, M., Bertsch, T., Lepiorz, D., Lang, S., Trinkmann, F., Brueckmann, M., Borggrefe, M., & Hoffmann, U. (2014) · Critical Care · doi:10.1186/s13054-014-0507-z · Cited by 227
“Soluble cluster of differentiation 14 subtype (sCD14-ST) so-called presepsin - is cleaved from the monocyte/macrophage-specific CD14 receptor complex after binding with lipopolysaccharides (LPS) and LPS binding protein (LPB) during systemic infections [7-10].”
BackgroundDevelopment of a point-of-care assay system for measurement of presepsin (sCD14-ST)
Okamura, Y., & Yokoi, H. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.07.024 · Cited by 216
“The PCT concentrations were measured using Elecsys® B·R·A·H·M·S PCT, which was from Roche (Tokyo, Japan).”
ResultInfluentialSelf-citationPresepsin (sCD14-ST), an innate immune response marker in sepsis
Chenevier-Gobeaux, C., Borderie, D., Weiss, N., Mallet-Coste, T., & Claessens, Y.-E. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.06.026 · Cited by 200
Wu, C.-C., Lan, H.-M., Han, S.-T., Chaou, C.-H., Yeh, C.-F., Liu, S.-H., Li, C.-H., Blaney, G. N., Liu, Z.-Y., & Chen, K.-F. (2017) · Annals of Intensive Care · doi:10.1186/s13613-017-0316-z · Cited by 193
Presepsin as a novel sepsis biomarker
Zou, Q., Wen, W., & Zhang, X.-C. (2014) · World Journal of Emergency Medicine · doi:10.5847/wjem.j.issn.1920-8642.2014.01.002 · Cited by 171
Masson, S., Caironi, P., Fanizza, C., Thomae, R., Bernasconi, R., Noto, A., Oggioni, R., Pasetti, G. S., Romero, M., Tognoni, G., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-014-3514-2 · Cited by 168
“Presepsin is emerging as a novel circulating marker of sepsis [10–15].”
BackgroundKondo, Y., Umemura, Y., Hayashida, K., Hara, Y., Aihara, M., & Yamakawa, K. (2019) · Journal of Intensive Care · doi:10.1186/s40560-019-0374-4 · Cited by 166
Novel biomarkers for sepsis: A narrative review
Larsen, F. F., & Petersen, J. A. (2017) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2017.09.030 · Cited by 161
Accuracy of Presepsin in Sepsis Diagnosis: A Systematic Review and Meta-Analysis
Wu, J., Hu, L., Zhang, G., Wu, F., & He, T. (2015) · PLOS ONE · doi:10.1371/journal.pone.0133057 · Cited by 158
Metadata
- Authors
- Shozushima, T., Takahashi, G., Matsumoto, N., Kojika, M., Endo, S., & Okamura, Y.
- Venue
- Journal of Infection and Chemotherapy
- Publisher
- Elsevier BV
- Published
- 2011
- Volume
- 17
- Issue
- 6
- Pages
- 764-769
- ISSN
- 1341-321X (ISSN-L)
- OpenAlex
- W2028842825
- Cited by
- 352
- References
- 4
- FWCI
- 11.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.