Deep learning-assisted diagnosis of placenta accreta spectrum using the DenseNet-121 model: a multicenter, retrospective study

Open access
Hu, Yurui, Liu, Tianyu, Pang, Shutong, Ling, Xiao, Wang, Zhanqiu, Li, Wenfei·2025·Journal of Imaging Informatics in Medicine

Abstract

To explore the diagnostic value of deep learning (DL) imaging based on MRI in predicting placenta accreta spectrum (PAS) in high-risk pregnant women. A total of 263 patients with suspected placenta accreta from Institution I and Institution II were retrospectively analyzed and divided into training (n = 170) and external verification sets (n = 93). Through imaging acquisition, feature extraction, and radiomic data processing, 15 radiomic features were used to train support vector machine (SVM), K-nearest neighbor (KNN), random forest (RF), light gradient boosting machine (LGBM), and DL models to predict PAS. The diagnostic performances of the models were evaluated in the training set using the area under the curve (AUC) and accuracy and further validated in the external verification set. Univariate and multivariate logistic regression analysis revealed that a history of cesarean section, placental thickness, and placenta previa were independent clinical risk factors for predicting PAS. Among machine learning (ML) models, SVM demonstrated the highest diagnostic power (AUC = 0.944), with an accuracy of 0.876. The diagnostic efficiency of the DL model was significantly better than that of other models, with an AUC of 0.956 (95% CI 0.931-0.981) in the training set and 0.863 (95% CI 0.816-0.910) in the external verification set. In terms of specificity, the DL model outperformed the ML models. The DL model based on MRI may demonstrate better performance in the diagnosis of PAS compared to traditional clinical models or ML radiomics models, as further confirmed by the external verification set.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s10278-025-01475-w

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Hu et al. evaluated the DenseNet-121 model, which enhanced diagnostic accuracy and improved interobserver reliability among radiologists for PAS diagnosis.

    “Comparatively, Hu et al. evaluated the DenseNet-121 model, a deep CNN across multiple centers. The model not only enhanced diagnostic accuracy but also improved interobserver reliability among radiologists.”

    From Machine Learning in Maternity: Early Diagnosis of Placenta Accreta Spectrum (2026) · cites this paper as [37]

    The Discussion (page unavailable) reports that the DenseNet-121 model had higher diagnostic accuracy for PAS than the clinical and machine-learning models, using data from two centers. The Segmentation and Feature Extraction section says one radiologist’s segmentation was reviewed by another, but the paper does not report improved interobserver reliability among radiologists. (LLM, conf=0.87)

    Experimental — accuracy not yet measured
  • Saliency mapping techniques incorporated by Hu et al. visually highlighted the most predictive regions on MRI scans, which is crucial for clinical trust and adoption.

    “Notably, Hu et al. incorporated saliency mapping techniques, which visually highlighted the most predictive regions on MRI scans. This interpretability aspect is crucial for clinical trust and adoption, as it allows physicians to understand and validate the decision-making process of the ML model [37].”

    From Machine Learning in Maternity: Early Diagnosis of Placenta Accreta Spectrum (2026) · cites this paper as [37]

    The Discussion (page unavailable) describes a visualization showing the placental implant location and weighting lesion areas, and says visual feature analysis demonstrated the model’s feasibility for clinical applications. It does not establish that the visualization allowed physicians to validate the model’s decisions or that it was crucial for clinical trust and adoption. (LLM, conf=0.83)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. [17]17. Model for Placenta Accreta Spectrum. Anesthesia and analgesia 2023;137:537-47.
  2. [22]22. Huang S, Cai N, Pacheco PP, Narrandes S, Wang Y, Xu W. Applications of Support Vector Machine (SVM) Learning in Cancer Genomics. Cancer genomics & proteomics 2018;15:41-51.

Cited by

Sorted by citations

Authors
Hu, Y., Liu, T., Pang, S., Ling, X., Wang, Z., & Li, W.
Affiliations
  • Hebei North University (CN)
  • Lanzhou University Second Hospital (CN)
  • First Hospital of Qinhuangdao (CN)
Corresponding author
Li, Wenfei
Venue
Journal of Imaging Informatics in Medicine
Published
2025-03-24
Volume
38
Issue
6
Pages
3899-3908
ISSN
  • 0897-1889 (ISSN-L)
  • 2948-2933
OpenAlex
W4408845293
Cited by
4
References
32
Citations by year
2026: 3 · 2025: 1
FWCI
6.09
Type
journal article
Language
en
Open access
Locations
  • Journal of Imaging Informatics in Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion)
Topics
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Maternal and fetal healthcare
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
placenta accreta spectrum, deep learning diagnosis, DenseNet121, magnetic resonance imaging, radiomics, high-risk pregnancy, cesarean section history, placental thickness, placenta previa, risk factors, external validation
MeSH terms
Deep Learning, Convolutional Neural Networks, Adult, Female, Humans, Magnetic Resonance Imaging, Placenta Accreta, Pregnancy, Retrospective Studies, Support Vector Machine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.