On-line biomass measurements in bioreactor cultivations: comparison study of two on-line probes
Open accessThe DOI matches its Crossref record.
Abstract
Two on-line probes for biomass measurement in bioreactor cultivations were evaluated. One probe is based on near infrared (NIR) light absorption and the other on dielectric spectroscopy. The probes were used to monitor biomass production in cultivations of several different microorganisms. Differences in NIR probe response compared to off-line measurement methods revealed that the most significant factor affecting the response was cell shape. The NIR light absorption method is more developed and reliable for on-line in situ biomass estimation than dielectric spectroscopy. The NIR light absorption method is, however, of no significant use, when the cultivation medium is not clear, and especially in processes using adsorbents or solid matrix for the microorganism to grow on. The possibilities offered by dielectric spectroscopy are impressive, but the on-line probe technology needs to be
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioreactor monitoring with spectroscopy and chemometrics: a review
Lourenço, N. D., Lopes, J. A., Almeida, C. F., Sarraguça, M. C., & Pinheiro, H. M. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6073-9 · Cited by 275
“MLR [64], locally weighted regression (LWR) [65] and univariate approaches [76, 77] have also been used, but the resulting models were not as robust as those obtained by use of PLS.”
MethodSensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224
Claßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
On-line infrared spectroscopy for bioprocess monitoring
Landgrebe, D., Haake, C., Höpfner, T., Beutel, S., Hitzmann, B., Scheper, T., Rhiel, M., & Reardon, K. F. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2743-8 · Cited by 134
“longum ATCC 15707 and DSM 14583 Biomass NIR Kiviharju et al. (2007)”
BackgroundInfluentialWechselberger, P., Sagmeister, P., & Herwig, C. (2013) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-012-0848-4 · Cited by 102
“, dependent on the media constituents and other process characteristics [13, 14], especially in”
Background
Metadata
- Authors
- Kiviharju, K., Salonen, K., Moilanen, U., Meskanen, E., Leisola, M., & Eerikäinen, T.
- Venue
- Journal of Industrial Microbiology & Biotechnology
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-06-21
- Volume
- 34
- Issue
- 8
- Pages
- 561-566
- ISSN
- 1367-5435 (ISSN-L)
- 1476-5535
- OpenAlex
- W2075699137
- Cited by
- 66
- References
- 0
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On-line biomass measurements in bioreactor cultivations: comparison study of two on-line probes. https://app.cochat.ai/papers/10.1007/s10295-007-0233-5
- The paper
- Kiviharju, K., Salonen, K., Moilanen, U., Meskanen, E., Leisola, M., & Eerikäinen, T. (2007). On-line biomass measurements in bioreactor cultivations: comparison study of two on-line probes. Journal of Industrial Microbiology & Biotechnology. https://doi.org/10.1007/s10295-007-0233-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.