Separation and Preconcentration by Dispersive Liquid–Liquid Microextraction Procedure: Recent Applications
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
DLLME's main limitation is lack of selectivity due to matrix interferences, especially for trace analytes in complex samples.
“Their main limitation is its lack of selectivity due to the presence of interferences from matrix, especially in analysis of trace analytes in a complex sample [18].”
From Determination of polycyclic aromatic hydrocarbons using lab on valve dispersive liquid–liquid microextraction coupled to high performance chromatography (2015) · cites this paper as [18]
DLLME is the most simple, rapid and environmental friendly approach among microextraction methods.
“Among these, the most simple, rapid and environmental friendly approach seems to be the DLLME procedure [18], introduced by Rezaee and co-workers [16].”
From Determination of polycyclic aromatic hydrocarbons using lab on valve dispersive liquid–liquid microextraction coupled to high performance chromatography (2015) · cites this paper as [18]
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402 · see citing works
Dispersive liquid-liquid microextraction for determination of organic analytes
Herrera-Herrera, A. V., Asensio-Ramos, M., Hernández-Borges, J., & Rodríguez-Delgado, M. Á. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.03.016 · Cited by 267 · see citing works
Separation and Preconcentration by Dispersive Liquid–Liquid Microextraction Procedure: A Review
Bosch Ojeda, C., & Sánchez Rojas, F. (2009) · Chromatographia · doi:10.1365/s10337-009-1104-1 · Cited by 124 · see citing works
Lili, L., Xu, H., Song, D., Cui, Y., Hu, S., & Zhang, G. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.081 · Cited by 123 · see citing works
Abdolmohammad-Zadeh, H., & Sadeghi, G. H. (2010) · Talanta · doi:10.1016/j.talanta.2010.01.012 · Cited by 86 · see citing works
Leong, M.-I., Chang, C.-C., Fuh, M.-R., & Huang, S.-D. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.06.056 · Cited by 80 · see citing works
Mashayekhi, H. A., Abroomand-Azar, P., Saber-Tehrani, M., & Husain, S. W. (2010) · Chromatographia · doi:10.1365/s10337-009-1456-6 · Cited by 71 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Recent developments in dispersive liquid–liquid microextraction
Saraji, M., & Boroujeni, M. K. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7467-z · Cited by 232 · see citing works
Fernández, M., Clavijo, S., Forteza, R., & Cerdà, V. (2015) · Talanta · doi:10.1016/j.talanta.2015.02.007 · Cited by 46 · see citing works
Qiao, L., Sun, R., Tao, Y., & Yan, Y. (2022) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462728 · Cited by 42 · see citing works
Greening Sample Preparation: New Solvents, New Sorbents
Ramos, L. (2020) · Challenges in Green Analytical Chemistry · doi:10.1039/9781788016148-00114 · Cited by 6 · see citing works
- Authors
- Ojeda, C. B., & Rojas, F. S.
- Affiliations
- Universidad de Málaga (ES)
- Corresponding author
- Rojas, Fuensanta Sánchez
- Venue
- Chromatographia
- Published
- 2011-08-25
- Volume
- 74
- Issue
- 9-10
- Pages
- 651-679
- ISSN
- 0009-5893 (ISSN-L)
- 1612-1112
- OpenAlex
- W1981999261
- Cited by
- 69
- References
- 7
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 6 · 2022: 4 · 2021: 1 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 1 · 2016: 7 · 2015: 6 · 2014: 12 · 2013: 13 · 2012: 9
- FWCI
- 10.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Chromatographia (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- dispersive liquid-liquid microextraction, preconcentration, sample separation, sample preparation, organic compounds, metal ions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review