A Highly Sensitive Dispersive Microextraction Method with Magnetic Carbon Nanocomposites Coupled with Dispersive Liquid–Liquid Microextraction and Two Miscible Stripping Solvents Followed by GC–MS for Quantification of 16 PAHs in Environmental Samples
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Under optimal conditions, the LOD values were in the range of 0.1-0.5 ng kg -1 at S/N = 3 and the method precision values were satisfactory (RSD% ≤ 8.66).”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [113]
In the citing paper
“Overall, the study results indicated that the combined MSPE-DLLME method shows excellent performance for the trace analysis of PAHs in environmental samples [113].”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [113]
In the citing paper
“Under optimal conditions, the LOD values were in the range of 0.1-0.5 ng kg -1 at S/N = 3 and the method precision values were satisfactory (RSD% ≤ 8.66).”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [113]
In the citing paper
“The results showed good linearity in the range of 0.4-10,000 ng kg -1 , with the correlation determinations between 0.9989 and 0.9999.”
From Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review (2020) · cites this paper as [113]
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402 · cited 1×
“Due to the structure of PAHs, different types of extraction solvents, lighter and heavier than water, have been reported for use in the DLLME procedure [17, 19, 30, 31].”
MethodBerijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
A new liquid-phase microextraction method based on solidification of floating organic drop
Khalili Zanjani, M. R., Yamini, Y., Shariati, S., & Jönsson, J. Å. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.12.049 · Cited by 512
Han, Q., Wang, Z., Xia, J., Chen, S., Zhang, X., & Ding, M. (2012) · Talanta · doi:10.1016/j.talanta.2012.09.046 · Cited by 362
Synthesis and properties of magnetic Fe3O4-activated carbon nanocomposite particles for dye removal
Yang, N., Zhu, S., Zhang, D., & Xu, S. (2008) · Materials Letters · doi:10.1016/j.matlet.2007.06.049 · Cited by 313
Doong, R.-A., Chang, S.-M., & Sun, Y.-C. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00347-2 · Cited by 267
Saleh, A., Yamini, Y., Faraji, M., Rezaee, M., & Ghambarian, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.08.001 · Cited by 262
Self-citationMa, J., Xiao, R., Li, J., Yu, J., Zhang, Y., & Chen, L. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.06.060 · Cited by 250
Shamsipur, M., Yazdanfar, N., & Ghambarian, M. (2016) · Food Chemistry · doi:10.1016/j.foodchem.2016.02.090 · Cited by 248
Self-citationSun, F., Littlejohn, D., & Gibson, M. D. (1998) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00186-x · Cited by 214
Popp, P., Bauer, C., & Wennrich, L. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)00895-9 · Cited by 203
Guo, L., & Lee, H. K. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.05.069 · Cited by 161
Kolahgar, B., Hoffmann, A., & Heiden, A. C. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00361-8 · Cited by 158
Shariati, S., Yamini, Y., & Bahramifar, N. (2003) · Analytica Chimica Acta · doi:10.1016/s0003-2670(03)00709-8 · Cited by 143
Tseng, W.-C., Chen, P., & Huang, S. (2014) · Talanta · doi:10.1016/j.talanta.2013.11.073 · Cited by 110
Polycyclic aromatic hydrocarbon analysis in different matrices of the marine environment
Filipkowska, A., Lubecki, L., & Kowalewska, G. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.05.023 · Cited by 108
Pincemaille, J., Schummer, C., Heinen, E., & Moris, G. (2013) · Food Chemistry · doi:10.1016/j.foodchem.2013.08.121 · Cited by 101
Kamankesh, M., Mohammadi, A., Hosseini, H., & Tehrani, Z. M. (2015) · Meat Science · doi:10.1016/j.meatsci.2015.01.001 · Cited by 101
Charalabaki, M., Psillakis, E., Mantzavinos, D., & Kalogerakis, N. (2005) · Chemosphere · doi:10.1016/j.chemosphere.2005.01.040 · Cited by 101 · cited 2×
“1 3 extraction (SPE) [1, 2, 5, 6], headspace solvent microextraction (HSME) [7], magnetic solid-phase extraction (MSPE) [8–11], homogeneous liquid–liquid microextraction [12], dispersive liquid–liquid microextraction (DLLME) [13–15], liquid-phase microextraction methods based on solidification of floating organic drop…”
MethodLiu, X., Lu, X., Huang, Y. X., Liu, C., & Zhao, S. (2013) · Talanta · doi:10.1016/j.talanta.2013.11.039 · Cited by 85
Reyes-Gallardo, E. M., Lucena, R., Cárdenas, S., & Valcárcel, M. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.04.033 · Cited by 74
López-Jiménez, F. J., Ballesteros‐Gómez, A., & Rubio, S. (2013) · Food Chemistry · doi:10.1016/j.foodchem.2013.07.136 · Cited by 56
Mehdinia, A., Khojasteh, E., Kayyal, T. B., & Jabbari, A. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.08.063 · Cited by 49
Fernández, M., Clavijo, S., Forteza, R., & Cerdà, V. (2015) · Talanta · doi:10.1016/j.talanta.2015.02.007 · Cited by 46
Tajabadi, F., Yamini, Y., & Sovizi, M. R. (2012) · Microchimica Acta · doi:10.1007/s00604-012-0913-3 · Cited by 33
Yazdanfar, N., Yamini, Y., & Ghambarian, M. (2013) · Chromatographia · doi:10.1007/s10337-013-2604-6 · Cited by 31
Self-citationZuazagoitia, D., Millán, E., & García, R. (2007) · Chromatographia · doi:10.1365/s10337-007-0371-y · Cited by 30
Simpson, S. L., Burston, V. L., Jolley, D. F., & Chau, K. (2006) · Chemosphere · doi:10.1016/j.chemosphere.2006.04.073 · Cited by 29
Bernal, J. L., Nozal, M. J., Toribio, L., Serna, M. L., Borrull, F., Marcé, R. M., & Pocurull, E. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)00388-9 · Cited by 28
Zuazagoitia, D., Millán, E., & García-Arrona, R. (2008) · Chromatographia · doi:10.1365/s10337-008-0843-8 · Cited by 24
Cacho, J. I., Campillo, N., Viñas, P., & Hernández‐Córdoba, M. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.06.060 · Cited by 21
Fladung, N. C. (1995) · Journal of Chromatography A · doi:10.1016/0021-9673(94)01135-2 · Cited by 17
Aragón, Á., Toledano, R. M., Vázquez, A., Villén, J., & Cortés, J. M. (2015) · Talanta · doi:10.1016/j.talanta.2015.02.028 · Cited by 12
Rahimi, M., & Noroozian, E. (2014) · Talanta · doi:10.1016/j.talanta.2014.02.002 · Cited by 6
Cited by
Recent Applications of Magnetic Solid-phase Extraction for Sample Preparation
Capriotti, A. L., Cavaliere, C., La Barbera, G., Montone, C. M., Piovesana, S., & Laganà, A. (2019) · Chromatographia · doi:10.1007/s10337-019-03721-0 · Cited by 170
Wu, A., Zhao, X., Wang, J., Tang, Z., Zhao, T., Niu, L., Yu, W., Yang, C., Fang, M., Lv, H., et al. (2020) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2020.1720493 · Cited by 106
Sample preparation and analytical methods for polycyclic aromatic hydrocarbons in sediment
Wu, L., Sun, R., Li, Y., & Sun, C. (2019) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2019.e00074 · Cited by 52
Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Reviews in Analytical Chemistry · doi:10.1515/revac-2020-0101 · Cited by 50
“Overall, the study results indicated that the combined MSPE–DLLME method shows excellent performance for the trace analysis of PAHs in environmental samples [113].”
MethodJinadasa, B. K. K. K., Monteau, F., & Morais, S. (2020) · Food Additives & Contaminants Part A · doi:10.1080/19440049.2020.1733103 · Cited by 43
Metadata
- Authors
- Yazdanfar, N., Shamsipur, M., Ghambarian, M., & Esrafili, A.
- Affiliations
- Razi University (IR)
- Academic Center for Education, Culture and Research (IR)
- Iran University of Medical Sciences (IR)
- Corresponding author
- Shamsipur, Mojtaba
- Venue
- Chromatographia
- Published
- 2018-01-19
- Volume
- 81
- Issue
- 3
- Pages
- 487-499
- ISSN
- 0009-5893 (ISSN-L)
- 1612-1112
- OpenAlex
- W2787870126
- Cited by
- 19
- References
- 34
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 3 · 2020: 4 · 2019: 6 · 2018: 2
- FWCI
- 2.34
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Chromatographia (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Toxic Organic Pollutants Impact
- Keywords
- polycyclic aromatic hydrocarbons, magnetic carbon nanocomposites, dispersive liquid-liquid microextraction, magnetic solid-phase extraction, environmental samples, wastewater, soil, water analysis, preconcentration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.