Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Dispersive Liquid−Liquid Microextraction Coupled with Dispersive μ-Solid-Phase Extraction for the Fast Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water Samples

Shi, Zhi-Guo, Lee, Hian Kee·2010·Analytical Chemistry

Abstract

A new two-step microextraction technique, combining dispersive liquid-liquid microextraction (DLLME) and dispersive microsolid-phase extraction (D-micro-SPE), was developed for the fast gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons (PAHs) in environmental samples. A feature of the new procedure lies in that any organic solvent immiscible with water can be used as extractant in DLLME. A special apparatus, such as conical-bottom test tubes, and tedious procedures of centrifugation, refrigeration of the solvent, and then thawing it, associated with classical DLLME or similar techniques are not necessary in the new procedure, which potentially lends itself to possible automation. In the present D-micro-SPE approach, hydrophobic magnetic nanoparticles were used to retrieve the extractant of 1-octanol in the DLLME step. It is noteworthy that the target of D-micro-SPE was the 1-octanol rather than the PAHs. Because of the rapid mass transfer associated with the DLLME and the D-micro-SPE steps, fast extraction could be achieved. Parameters affecting the extraction efficiency were investigated in detail. The optimal conditions were as follows: vortex at 3200 rpm in the DLLME step for 2 min and in D-micro-SPE for 1 min and then desorption by sonication for 4 min with acetonitrile as the solvent. The results demonstrated that enrichment factors ranging from 110- to 186-fold were obtained for the analytes. The limits of detection and the limits of quantification were in the range of 11.7-61.4 pg/mL and 0.04-0.21 ng/mL, respectively. The linearities were 0.5-50, 1-50, or 2-50 ng/mL for different PAHs. Finally, the two-step extraction method was successfully used for the fast determination of PAHs in river water samples. This two-step method, combining two different and efficient miniaturized techniques, provides a fast means of sample pretreatment for environmental water samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac9023632

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Research works printed but not linked: 27

  1. Arthur C. L., 1990, Anal. Chem., 62, 2145, 10.1021/ac00218a019 · DOI · Paper page
  2. Dietz C., 2006, J. Chromatogr., A, 1103, 183, 10.1016/j.chroma.2005.11.041 · DOI · Paper page
  3. Svec F., 2006, J. Chromatogr., B, 841, 52, 10.1016/j.jchromb.2006.03.055 · doi:10.1016/j.jchromb.2006.03.055
  4. Zheng M. M., 2007, J. Chromatogr., A, 1164, 48, 10.1016/j.chroma.2007.07.020 · DOI
  5. Dietz C., 2006, J. Chromatogr., A, 1103, 183, 10.1016/j.chroma.2005.11.041 · DOI · Paper page
  6. Liu H. H., 1996, Anal. Chem., 68, 1817, 10.1021/ac960145h · DOI · Paper page
  7. He Y., 1997, Anal. Chem., 69, 4634, 10.1021/ac970242q · DOI · Paper page
  8. Kokosa J. M., 2003, J. Chromatogr., A, 983, 205, 10.1016/S0021-9673(02)01686-2 · DOI
  9. Pedersen-Bjergaard S., 1999, Anal. Chem., 71, 2650, 10.1021/ac990055n · DOI · Paper page
  10. Xu L., 2007, J. Chromatogr., A, 1152, 184, 10.1016/j.chroma.2006.10.073 · DOI · Paper page
  11. Lambropoulou D. A., 2007, J. Chromatogr., A, 1152, 70, 10.1016/j.chroma.2007.02.094 · DOI
  12. David F., 2007, J. Chromatogr., A, 1152, 54, 10.1016/j.chroma.2007.01.032 · DOI · Paper page
  13. Barri T., 2008, J. Chromatogr., A, 1186, 16, 10.1016/j.chroma.2008.02.002 · DOI
  14. Hylton K., 2007, J. Chromatogr., A, 1152, 199, 10.1016/j.chroma.2006.12.047 · DOI
  15. Basheer C., 2006, Anal. Chem., 78, 2853, 10.1021/ac060240i · DOI · Paper page
  16. García-López M., 2007, J. Chromatogr., A, 1166, 9, 10.1016/j.chroma.2007.08.006 · DOI
  17. Fariña L., 2007, J. Chromatogr., A, 1157, 46, 10.1016/j.chroma.2007.05.006 · DOI · Paper page
  18. Zang X., 2008, Anal. Bioanal. Chem., 392, 749, 10.1007/s00216-008-2296-1 · DOI · Paper page
  19. Rezaee M., 2009, J. Chromatogr., A, 1216, 1511, 10.1016/j.chroma.2008.12.091 · DOI · Paper page
  20. Cruz-Vera M., 2009, J. Chromatogr., A, 1216, 6459, 10.1016/j.chroma.2009.07.040 · DOI · Paper page
  21. Leong M. I., 2008, J. Chromatogr., A, 1211, 8, 10.1016/j.chroma.2008.09.111 · DOI · Paper page
  22. Farajzadeh M. A., 2009, J. Sep. Sci., 32, 3191, 10.1002/jssc.200900109 · DOI · Paper page
  23. Barker S. A., 1989, J. Chromatogr., 475, 353, 10.1016/S0021-9673(01)89689-8 · DOI · Paper page
  24. Barker S. A., 2007, J. Biochem. Biophys. Methods, 70, 151, 10.1016/j.jbbm.2006.06.005 · DOI · Paper page
  25. Deng H., 2005, Angew. Chem., Int. Ed., 44, 2782, 10.1002/anie.200462551 · DOI · Paper page
  26. Rianawati E., 2009, Phys. Chem. Earth, 34, 857, 10.1016/j.pce.2009.07.003 · DOI
  27. Xu L., 2009, J. Chromatogr., A, 1216, 5483, 10.1016/j.chroma.2009.05.074 · DOI

Cited by

See all 230

Metadata

Authors
Shi, Z.-G., & Lee, H. K.
Venue
Analytical Chemistry
Published
2010-01-21
Volume
82
Issue
4
Pages
1540-1545
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2005770731
Cited by
230
References
6
FWCI
24.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dispersive Liquid−Liquid Microextraction Coupled with Dispersive μ-Solid-Phase Extraction for the Fast Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water Samples. https://app.cochat.ai/papers/10.1021/ac9023632
The paper
Shi, Z.-G., & Lee, H. K. (2010). Dispersive Liquid−Liquid Microextraction Coupled with Dispersive μ-Solid-Phase Extraction for the Fast Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water Samples. Analytical Chemistry. https://doi.org/10.1021/ac9023632

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.