Application of L1-Norm Regularization to Epicardial Potential Solution of the Inverse Electrocardiography Problem
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The electrocardiographic inverse problem of computing epicardial potentials from multi-electrode body-surface ECG measurements, is an ill-posed problem. Tikhonov regularization is commonly employed, which imposes penalty on the L2-norm of the potentials (zero-order) or their derivatives. Previous work has indicated superior results using L2-norm of the normal derivative of the solution (a first order regularization). However, L2-norm penalty function can cause considerable smoothing of the solution. Here, we use the L1-norm of the normal derivative of the potential as a penalty function. L1-norm solutions were compared to zero-order and first-order L2-norm Tikhonov solutions and to measured ‘gold standards’ in previous experiments with isolated canine hearts. Solutions with L1-norm penalty function (average relative error [RE] = 0.36) were more accurate than L2-norm (average RE = 0.62). In addition, the L1-norm method localized epicardial pacing sites with better accuracy (3.8 ± 1.5 mm) compared to L2-norm (9.2 ± 2.6 mm) during pacing in five pediatric patients with congenital heart disease. In a pediatric patient with Wolff–Parkinson–White syndrome, the L1-norm method also detected and localized two distinct areas of early activation around the mitral valve annulus, indicating the presence of two left-sided pathways which were not distinguished using L2 regularization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive electrocardiographic imaging for cardiac electrophysiology and arrhythmia
Ramanathan, C., Ghanem, R. N., Jia, P., Ryu, K., & Rudy, Y. (2004) · Nature Medicine · doi:10.1038/nm1011 · Cited by 646
Self-citationSparse source imaging in electroencephalography with accurate field modeling
Ding, L., & He, B. (2008) · Human Brain Mapping · doi:10.1002/hbm.20448 · Cited by 131
Ghosh, S., Rhee, E. K., Avari, J. N., Woodard, P. K., & Rudy, Y. (2008) · Circulation · doi:10.1161/circulationaha.108.781658 · Cited by 89
Self-citation
Cited by
Zhang, C. D., & Xu, Y. L. (2016) · Structural Control and Health Monitoring · doi:10.1002/stc.1785 · Cited by 106
“Even though the sparsity constraint has been exploited and adopted in solving inverse problems in other disciplines [9,10], only until very recently it has begun to attract some attention in structural health monitoring applications.”
BackgroundHernandez, E. M. (2014) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2013.12.009 · Cited by 74
Investigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model
Mäntynen, V., Konttila, T., & Stenroos, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/23/7141 · Cited by 45
Xu, J., Sapp, J. L., Dehaghani, A. R., Gao, F., Horacek, M., & Wang, L. (2015) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-24571-3_62 · Cited by 15
Metadata
- Authors
- Ghosh, S., & Rudy, Y.
- Venue
- Annals of Biomedical Engineering
- Published
- 2009-03-06
- Volume
- 37
- Issue
- 5
- Pages
- 902-912
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2012155513
- Cited by
- 120
- References
- 3
- FWCI
- 5.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of L1-Norm Regularization to Epicardial Potential Solution of the Inverse Electrocardiography Problem. https://app.cochat.ai/papers/10.1007/s10439-009-9665-6
- The paper
- Ghosh, S., & Rudy, Y. (2009). Application of L1-Norm Regularization to Epicardial Potential Solution of the Inverse Electrocardiography Problem. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-009-9665-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.