The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Quantification of Hemodynamics in Abdominal Aortic Aneurysms During Rest and Exercise Using Magnetic Resonance Imaging and Computational Fluid Dynamics
Open accessAbstract
Abdominal aortic aneurysms (AAAs) affect 5–7% of older Americans. We hypothesize that exercise may slow AAA growth by decreasing inflammatory burden, peripheral resistance, and adverse hemodynamic conditions such as low, oscillatory shear stress. In this study, we use magnetic resonance imaging and computational fluid dynamics to describe hemodynamics in eight AAAs during rest and exercise using patient-specific geometric models, flow waveforms, and pressures as well as appropriately resolved finite-element meshes. We report mean wall shear stress (MWSS) and oscillatory shear index (OSI) at four aortic locations (supraceliac, infrarenal, mid-aneurysm, and suprabifurcation) and turbulent kinetic energy over the entire computational domain on meshes containing more than an order of magnitude more elements than previously reported results (mean: 9.0-million elements; SD: 2.3 M; range: 5.7–12.0 M). MWSS was lowest in the aneurysm during rest 2.5 dyn/cm2 (SD: 2.1; range: 0.9–6.5), and MWSS increased and OSI decreased at all four locations during exercise. Mild turbulence existed at rest, while moderate aneurysmal turbulence was present during exercise. During both rest and exercise, aortic turbulence was virtually zero superior to the AAA for seven out of eight patients. We postulate that the increased MWSS, decreased OSI, and moderate turbulence present during exercise may attenuate AAA growth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Finite Element Method: Linear Static and Dynamic Finite Element Analysis
Hughes, T. J. R. (1987) · Cited by 4,852
Exercise capacity and mortality among men referred for exercise testing
Myers, J., Prakash, M., Froelicher, V., Do, D., Partington, S., & Atwood, J. E. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011858 · Cited by 4,114
Womersley, J. R. (1955) · The Journal of Physiology · doi:10.1113/jphysiol.1955.sp005276 · Cited by 1,835
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
Brewster, D. C., Cronenwett, J. L., Hallett, J. W., Johnston, K. W., Krupski, W. C., & Matsumura, J. S. (2003) · Journal of Vascular Surgery · doi:10.1067/mva.2003.363 · Cited by 836
The Aneurysm Detection and Management Study Screening Program: Validation Cohort and Final Results
Lederle, F. A. (2000) · Archives of Internal Medicine · doi:10.1001/archinte.160.10.1425 · Cited by 722
Abdominal Aortic Aneurysm Expansion: Risk Factors and Time Intervals for Surveillance
Brady, A. R., Thompson, S. G., Fowkes, F. G. R., Greenhalgh, R. M., & Powell, J. T. (2004) · Circulation · doi:10.1161/01.cir.0000133279.07468.9f · Cited by 685
Vignon-Clementel, I. E., Alberto Figueroa, C., Jansen, K. E., & Taylor, C. A. (2006) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2005.04.014 · Cited by 646
Self-citationBoussel, L., Rayz, V., McCulloch, C., Martin, A., Acevedo-Bolton, G., Lawton, M., Higashida, R., Smith, W. S., Young, W. L., & Saloner, D. (2008) · Stroke · doi:10.1161/strokeaha.108.521617 · Cited by 535
Fleming, C., Whitlock, E. P., Beil, T. L., & Lederle, F. A. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-142-3-200502010-00012 · Cited by 509
Perktold, K., & Rappitsch, G. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)95273-8 · Cited by 493
Thompson, R. W., Holmes, D. R., Mertens, R. A., Liao, S., Botney, M. D., Mecham, R. P., Welgus, H. G., & Parks, W. C. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118037 · Cited by 460
MOOREJR, J., XU, C., GLAGOV, S., ZARINS, C., & KU, D. (1994) · Atherosclerosis · doi:10.1016/0021-9150(94)90207-0 · Cited by 425
Taylor, C. A., Hughes, T. J. R., & Zarins, C. K. (1998) · Annals of Biomedical Engineering · doi:10.1114/1.140 · Cited by 373
Self-citationEpidemiology of aortic aneurysm in the United States
Gillum, R. F. (1995) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(95)00045-3 · Cited by 308
Whiting, C. H., & Jansen, K. E. (2001) · International Journal for Numerical Methods in Fluids · doi:10.1002/1097-0363(20010115)35:1 · Cited by 300
Humphrey, J. D., & Taylor, C. A. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160439 · Cited by 298
Self-citationE XPERIMENTAL AND C OMPUTATIONAL M ETHODS IN C ARDIOVASCULAR F LUID M ECHANICS
Taylor, C. A., & Draney, M. T. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.121944 · Cited by 285
Self-citationOxidative Stress in Human Abdominal Aortic Aneurysms: A Potential Mediator of Aneurysmal Remodeling
Miller, F. J., Sharp, W. J., Fang, X., Oberley, L. W., Oberley, T. D., & Weintraub, N. L. (2002) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000013778.72404.30 · Cited by 276
Taylor, C. A., & Steinman, D. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9901-0 · Cited by 261
Self-citationHuman red blood cell hemolysis in a turbulent shear flow: Contribution of Reynolds shear stresses
Sallam, A. M., & Hwang, N. H. C. (1984) · Biorheology · doi:10.3233/bir-1984-21605 · Cited by 245
Koch, A. E., Kunkel, S. L., Pearce, W. H., Shah, M. R., Parikh, D., Evanoff, H. L., Haines, G. K., Burdick, M. D., & Strieter, R. M. (1993) · PubMed Central · Cited by 241
Perktold, K., Peter, R. O., Resch, M., & Langs, G. (1991) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(91)90100-l · Cited by 211
Use of pulse pressure method for estimating total arterial compliance in vivo
Stergiopulos, N., Segers, P., & Westerhof, N. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.2.h424 · Cited by 211
Cytokines that activate proteolysis are increased in abdominal aortic aneurysms.
Km, N., Jean-Claude, J. M., Li, H., Ramey, W. G., & Tilson, M. D. (1994) · PubMed · Cited by 208
Hance, K. A., Tataria, M., Ziporin, S. J., Lee, J. K., & Thompson, R. W. (2002) · Journal of Vascular Surgery · doi:10.1067/mva.2002.120382 · Cited by 174
Taylor, C. A., Cheng, C. P., Espinosa, L. A., Tang, B. T., Parker, D., & Herfkens, R. J. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1476016 · Cited by 174
Self-citationTang, B. T., Cheng, C. P., Draney, M. T., Wilson, N. M., Tsao, P. S., Herfkens, R. J., & Taylor, C. A. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01301.2005 · Cited by 157
Self-citationSalsac, A., SPARKS, S. R., Chomaz, J., & Lasheras, J. C. (2006) · Journal of Fluid Mechanics · doi:10.1017/s002211200600036x · Cited by 120
Topography of human aortic sudanophilic lesions.
Cornhill, J. F., Herderick, E. E., & Stary, H. C. (1990) · PubMed · Cited by 114
(1952) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1952.tb94634.x · Cited by 113
Peattie, R. A., Riehle, T. J., & Bluth, E. I. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1784478 · Cited by 107
Cheng, C. P., Herfkens, R. J., & Taylor, C. A. (2003) · Atherosclerosis · doi:10.1016/s0021-9150(03)00099-6 · Cited by 103
Self-citationSteele, B. N., Olufsen, M. S., & Taylor, C. A. (2007) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840601068638 · Cited by 93
Self-citationWaveform dispersion, not reflection, may be the major determinant of aortic pressure wave morphology
Hope, S. A., Tay, D. B. H., Meredith, I. T., & Cameron, J. D. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00411.2005 · Cited by 60
Aortoiliac hemodynamic and morphologic adaptation to chronic spinal cord injury
Yeung, J. J., Kim, H. J., Abbruzzese, T. A., Vignon-Clementel, I. E., Draney, M. T., Yeung, K. K., Perkash, I., Herfkens, R. J., Taylor, C. A., & Dalman, R. L. (2006) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2006.08.026 · Cited by 57
Self-citationBax, L., Bakker, C. J. G., Klein, W. M., Blanken, N., Beutler, J. J., & Mali, W. P. T. M. (2005) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000161144.98350.28 · Cited by 49
Dalman, R. L., Tedesco, M. M., Myers, J., & Taylor, C. A. (2006) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1383.008 · Cited by 46
Self-citationNephrogenic systemic fibrosis and the role of gadolinium contrast media
van der Molen, A. J. (2008) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/j.1440-1673.2008.01965.x · Cited by 33
Altered hemodynamics during exercise in older essential hypertensive subjects.
Montain, S. J., Jilka, S. M., Ehsani, A. A., & Hagberg, J. M. (1988) · Hypertension · doi:10.1161/01.hyp.12.5.479 · Cited by 28
Long, A., Rouet, L., Vitry, F., Albertini, J. N., Marcus, C. D., & Clément, C. (2008) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2008.08.006 · Cited by 27
Cited by
Chaikof, E. L., Dalman, R. L., Eskandari, M. K., Jackson, B. M., Lee, W. A., Mansour, M. A., Mastracci, T. M., Mell, M., Murad, M. H., Nguyen, L. L., et al. (2018) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2017.10.044 · Cited by 2,751
Self-citationSimVascular: An Open Source Pipeline for Cardiovascular Simulation
Updegrove, A., Wilson, N. M., Merkow, J., Lan, H., Marsden, A. L., & Shadden, S. C. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1762-8 · Cited by 651
Self-citationTaylor, C. A., & Steinman, D. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9901-0 · Cited by 261
Self-citation
Metadata
- Authors
- Les, A. S., Shadden, S. C., Figueroa, C. A., Park, J. M., Tedesco, M. M., Herfkens, R. J., Dalman, R. L., & Taylor, C. A.
- Venue
- Annals of Biomedical Engineering
- Published
- 2010-02-09
- Volume
- 38
- Issue
- 4
- Pages
- 1288-1313
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2118951490
- Cited by
- 314
- References
- 41
- FWCI
- 12.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.