The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High Fluid Shear Stress and Spatial Shear Stress Gradients Affect Endothelial Proliferation, Survival, and Alignment
Open accessAbstract
Cerebral aneurysms develop near bifurcation apices, where complex hemodynamics occur: Flow impinges on the apex, accelerates into branches, then slows again distally, creating high wall shear stress (WSS) and positive and negative spatial gradients in WSS (WSSG). Endothelial responses to these kinds of high WSS hemodynamic environments are not well characterized. We examined endothelial cells (ECs) under elevated WSS and positive and negative WSSG using a flow chamber with constant-height channels to create regions of uniform WSS and converging and diverging channels to create positive and negative WSSG, respectively. Cultured bovine aortic ECs were subjected to 3.5 and 28.4 Pa with and without WSSG for 24 and 36 h. High WSS inhibited EC alignment to flow, increased EC proliferation assessed by bromodeoxyuridine incorporation, and increased apoptosis determined by terminal deoxynucleotidyl transferase dUTP-mediated nick-end labeling. These responses to high WSS were either accentuated or ameliorated by WSSG: Positive WSSG (+980 Pa/m) inhibited alignment and stimulated proliferation and apoptosis, whereas negative WSSG (−1120 Pa/m) promoted alignment and suppressed proliferation and apoptosis. These results demonstrate that ECs discriminate between positive and negative WSSG under high WSS conditions. EC responses to positive WSSG may contribute to pathogenic remodeling that occurs at bifurcations preceding aneurysm formation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
High Wall Shear Stress and Spatial Gradients in Vascular Pathology: A Review
Dolan, J. M., Kolega, J., & Meng, H. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0695-0 · Cited by 411
Self-citationGijsen, F., Katagiri, Y., Barlis, P., Bourantas, C., Collet, C., Coskun, U., Daemen, J., Dijkstra, J., Edelman, E., Evans, P., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz551 · Cited by 315
Nanoparticle protein corona: from structure and function to therapeutic targeting
Bashiri, G., Padilla, M. S., Swingle, K. L., Shepherd, S. J., Mitchell, M. J., & Wang, K. (2023) · Lab on a Chip · doi:10.1039/d2lc00799a · Cited by 296
4D Flow CMR in Assessment of Valve-Related Ascending Aortic Disease
Hope, M. D., Hope, T. A., Crook, S. E. S., Ordovas, K. G., Urbania, T. H., Alley, M. T., & Higgins, C. B. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2011.05.004 · Cited by 273
Engineering cell alignment in vitro
Li, Y., Huang, G., Zhang, X., Wang, L., Du, Y., Lu, T. J., & Xu, F. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.11.007 · Cited by 272
Metadata
- Authors
- Dolan, J. M., Meng, H., Singh, S., Paluch, R., & Kolega, J.
- Venue
- Annals of Biomedical Engineering
- Published
- 2011-02-11
- Volume
- 39
- Issue
- 6
- Pages
- 1620-1631
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2039797702
- Cited by
- 172
- References
- 1
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High Fluid Shear Stress and Spatial Shear Stress Gradients Affect Endothelial Proliferation, Survival, and Alignment. https://app.cochat.ai/papers/10.1007/s10439-011-0267-8
- The paper
- Dolan, J. M., Meng, H., Singh, S., Paluch, R., & Kolega, J. (2011). High Fluid Shear Stress and Spatial Shear Stress Gradients Affect Endothelial Proliferation, Survival, and Alignment. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-011-0267-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.