SimVascular: An Open Source Pipeline for Cardiovascular Simulation
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Patient-specific cardiovascular simulation has become a paradigm in cardiovascular research and is emerging as a powerful tool in basic, translational and clinical research. In this paper we discuss the recent development of a fully open-source SimVascular software package, which provides a complete pipeline from medical image data segmentation to patient-specific blood flow simulation and analysis. This package serves as a research tool for cardiovascular modeling and simulation, and has contributed to numerous advances in personalized medicine, surgical planning and medical device design. The SimVascular software has recently been refactored and expanded to enhance functionality, usability, efficiency and accuracy of image-based patient-specific modeling tools. Moreover, SimVascular previously required several licensed components that hindered new user adoption and code management and our recent developments have replaced these commercial components to create a fully open source pipeline. These developments foster advances in cardiovascular modeling research, increased collaboration, standardization of methods, and a growing developer community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Braunwald, E., Antman, E. M., Beasley, J. W., Califf, R. M., Cheitlin, M. D., Hochman, J. S., Jones, R. H., Kereiakes, D., Kupersmith, J., Levin, T. N., et al. (2000) · Circulation · doi:10.1161/01.cir.102.10.1193 · Cited by 4,487
Hemodynamic shear stress and its role in atherosclerosis
Malek, A. M. (1999) · JAMA · doi:10.1001/jama.282.21.2035 · Cited by 3,650
Ku, D. N., Giddens, D. P., Zarins, C. K., & Glagov, S. (1985) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.5.3.293 · Cited by 2,707
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Li, C., Huang, R., Ding, Z., Gatenby, J. C., Metaxas, D. N., & Gore, J. C. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2146190 · Cited by 1,285
Taylor, C. A., Fonte, T. A., & Min, J. K. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.083 · Cited by 1,208
Braunwald, E., Antman, E. M., Beasley, J. W., Califf, R. M., Cheitlin, M. D., Hochman, J. S., Jones, R. H., Kereiakes, D., Kupersmith, J., Levin, T. N., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02336-7 · Cited by 1,116
Review of MR image segmentation techniques using pattern recognition
Bezdek, J. C., Hall, L. O., & Clarke, L. P. (1993) · Medical Physics · doi:10.1118/1.597000 · Cited by 953
Braunwald, E. (2002) · Journal of the American College of Cardiology · Cited by 868
Olufsen, M. S., Peskin, C. S., Kim, W. Y., Pedersen, E. M., Nadim, A., & Larsen, J. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1326031 · Cited by 862
McDONALD'S BLOOD FLOW IN ARTERIES: THEORETICAL, EXPERIMENTAL AND CLINICAL PRINCIPLES
Czuwala, P. J. (1991) · Echocardiography · doi:10.1111/j.1540-8175.1991.tb01207.x · Cited by 820
Stabilized finite element methods: II. The incompressible Navier-Stokes equations
Franca, L. P., & Frey, S. L. (1992) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(92)90041-h · Cited by 758
Finite element modeling of blood flow in arteries
Taylor, C. A., Hughes, T. J. R., & Zarins, C. K. (1998) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/s0045-7825(98)80008-x · Cited by 726
Vignon-Clementel, I. E., Alberto Figueroa, C., Jansen, K. E., & Taylor, C. A. (2006) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2005.04.014 · Cited by 646
Patient-Specific Modeling of Blood Flow and Pressure in Human Coronary Arteries
Kim, H. J., Vignon-Clementel, I. E., Coogan, J. S., Figueroa, C. A., Jansen, K. E., & Taylor, C. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0083-6 · Cited by 628
A coupled momentum method for modeling blood flow in three-dimensional deformable arteries
Figueroa, C. A., Vignon-Clementel, I. E., Jansen, K. E., Hughes, T. J. R., & Taylor, C. A. (2006) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2005.11.011 · Cited by 547
Biomechanical factors in atherosclerosis: mechanisms and clinical implications
Kwak, B. R., Bäck, M., Bochaton-Piallat, M.-L., Caligiuri, G., Daemen, M. J. A. P., Davies, P. F., Hoefer, I. E., Holvoet, P., Jo, H., Krams, R., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu353 · Cited by 502
Davies, P. F., Civelek, M., Fang, Y., & Fleming, I. (2013) · Cardiovascular Research · doi:10.1093/cvr/cvt101 · Cited by 331
Les, A. S., Shadden, S. C., Figueroa, C. A., Park, J. M., Tedesco, M. M., Herfkens, R. J., Dalman, R. L., & Taylor, C. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9949-x · Cited by 314
Self-citationKrams, R., Wentzel, J. J., Oomen, J. A. F., Vinke, R., Schuurbiers, J. C. H., de Feyter, P. J., Serruys, P. W. J. C., & Slager, C. J. (1997) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.17.10.2061 · Cited by 309
Whiting, C. H., & Jansen, K. E. (2001) · International Journal for Numerical Methods in Fluids · doi:10.1002/1097-0363(20010115)35:1 · Cited by 300
Milner, J. S., Moore, J. A., Rutt, B. K., & Steinman, D. A. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)70210-1 · Cited by 276
Modeling of Congenital Hearts Alliance (MOCHA), Esmaily Moghadam, M., Bazilevs, Y., Hsia, T.-Y., Vignon-Clementel, I. E., & Marsden, A. L. (2011) · Computational Mechanics · doi:10.1007/s00466-011-0599-0 · Cited by 268
Self-citationAtherosclerosis at arterial bifurcations: evidence for the role of haemodynamics and geometry
Morbiducci, U., Kok, A. M., Kwak, B. R., Stone, P. H., Steinman, D. A., & Wentzel, J. J. (2016) · Thrombosis and Haemostasis · doi:10.1160/th15-07-0597 · Cited by 258
Predictive medicine: Computational techniques in therapeutic decision-making
Taylor, C. A., Draney, M. T., Ku, J. P., Parker, D., Steele, B. N., Wang, K., & Zarins, C. K. (1999) · Computer Aided Surgery · doi:10.1002/(sici)1097-0150(1999)4:5<231::aid-igs1>3.0.co;2-z · Cited by 257
Patient-Specific Multiscale Modeling of Blood Flow for Coronary Artery Bypass Graft Surgery
Sankaran, S., Esmaily Moghadam, M., Kahn, A. M., Tseng, E. E., Guccione, J. M., & Marsden, A. L. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0579-3 · Cited by 237
Self-citationPredictive Medicine: Computational Techniques in Therapeutic Decision-Making
Taylor, C. A., Draney, M. T., Ku, J. P., Parker, D., Steele, B. N., Wang, K., & Zarins, C. K. (1999) · Computer Aided Surgery · doi:10.3109/10929089909148176 · Cited by 221
Evaluation of a novel Y-shaped extracardiac Fontan baffle using computational fluid dynamics
Marsden, A. L., Bernstein, A. J., Reddy, V. M., Shadden, S. C., Spilker, R. L., Chan, F. P., Taylor, C. A., & Feinstein, J. A. (2009) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2008.06.043 · Cited by 200
Self-citationA modular numerical method for implicit 0D/3D coupling in cardiovascular finite element simulations
Esmaily Moghadam, M., Vignon-Clementel, I. E., Figliola, R., & Marsden, A. L. (2013) · Journal of Computational Physics · doi:10.1016/j.jcp.2012.07.035 · Cited by 190
Self-citationFramelet Algorithms for De-Blurring Images Corrupted by Impulse Plus Gaussian Noise
Li, Y.-R., Shen, L., Dai, D.-Q., & Suter, B. W. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2010.2103950 · Cited by 177
Efficient anisotropic adaptive discretization of the cardiovascular system
Sahni, O., Müller, J., Jansen, K. E., Shephard, M. S., & Taylor, C. A. (2006) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2005.10.018 · Cited by 165
Wentzel, J. J., Janssen, E., Vos, J., Schuurbiers, J. C. H., Krams, R., Serruys, P. W., de Feyter, P. J., & Slager, C. J. (2003) · Circulation · doi:10.1161/01.cir.0000078637.21322.d3 · Cited by 162
Characterization of Coherent Structures in the Cardiovascular System
Shadden, S. C., & Taylor, C. A. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9502-3 · Cited by 149
Self-citationSteinman, D. A., Hoi, Y., Fahy, P., Morris, L., Walsh, M. T., Aristokleous, N., Anayiotos, A. S., Papaharilaou, Y., Arzani, A., Shadden, S. C., et al. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4023382 · Cited by 141
Self-citationMoore, J. A., Steinman, D. A., Holdsworth, D. W., & Ethier, C. R. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.163 · Cited by 133
Quantification of regional differences in aortic stiffness in the aging human
Roccabianca, S., Figueroa, C. A., Tellides, G., & Humphrey, J. D. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.01.026 · Cited by 131
Esmaily-Moghadam, M., Bazilevs, Y., & Marsden, A. (2013) · Computational Mechanics · doi:10.1007/s00466-013-0868-1 · Cited by 119
Self-citationArzani, A., Suh, G.-Y. K., Dalman, R. L., & Shadden, S. C. (2014) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00461.2014 · Cited by 110
Self-citationTran, J. S., Schiavazzi, D. E., Ramachandra, A. B., Kahn, A. M., & Marsden, A. L. (2016) · Computers & Fluids · doi:10.1016/j.compfluid.2016.05.015 · Cited by 102
Self-citationSuh, G.-Y. K., Les, A. S., Tenforde, A. S., Shadden, S. C., Spilker, R. L., Yeung, J. J., Cheng, C. P., Herfkens, R. J., Dalman, R. L., & Taylor, C. A. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0313-6 · Cited by 99
Self-citationMultiscale Modeling of Cardiovascular Flows for Clinical Decision Support
Marsden, A. L., & Esmaily, M. (2015) · Applied Mechanics Reviews · doi:10.1115/1.4029909 · Cited by 95
Self-citationIn Vitro Validation of Finite Element Analysis of Blood Flow in Deformable Models
Kung, E. O., Les, A. S., Figueroa, C. A., Medina, F. R., Arcaute, K., Wicker, R. B., McConnell, M. V., & Taylor, C. A. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0284-7 · Cited by 95
Kung, E. O., Baretta, A., Baker, C., Arbia, G., Biglino, G., Corsini, C. A., Schievano, S., Vignon-Clementel, I. E., Dubini, G., Pennati, G., et al. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.10.023 · Cited by 95
Self-citationCoogan, J. S., Humphrey, J. D., & Figueroa, C. A. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-012-0383-x · Cited by 86
Oakes, J. M., Marsden, A. L., Grandmont, C., Shadden, S. C., Darquenne, C., & Vignon-Clementel, I. E. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0954-8 · Cited by 80
Self-citationIn Vivo Validation of Numerical Prediction for Turbulence Intensity in an Aortic Coarctation
Arzani, A., Dyverfeldt, P., Ebbers, T., & Shadden, S. C. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0447-6 · Cited by 79
Self-citationComputational Investigations in Vascular Disease
Taylor, C. A., Hughes, T. J. R., & Zarins, C. K. (1996) · Computers in Physics · doi:10.1063/1.4822390 · Cited by 79
Schiavazzi, D. E., Arbia, G., Baker, C., Hlavacek, A. M., Hsia, T. Y., Marsden, A. L., Vignon‐Clementel, I. E., & of Congenital Hearts Alliance (MOCHA) Investigators, T. M. (2016) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2737 · Cited by 75
Self-citationYang, W., Chan, F. P., Reddy, V. M., Marsden, A. L., & Feinstein, J. A. (2014) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2014.08.069 · Cited by 74
Self-citationA robust and efficient valve model based on resistive immersed surfaces
Astorino, M., Hamers, J., Shadden, S. C., & Gerbeau, J.-F. (2012) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2474 · Cited by 67
Self-citationRamachandra, A. B., Kahn, A. M., & Marsden, A. L. (2016) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-016-9706-0 · Cited by 58
Self-citationSize-dependent predilections of cardiogenic embolic transport
Carr, I. A., Nemoto, N., Schwartz, R. S., & Shadden, S. C. (2013) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00320.2013 · Cited by 57
Self-citationMukherjee, D., Jani, N. D., Selvaganesan, K., Weng, C. L., & Shadden, S. C. (2016) · Journal of Biomechanical Engineering · doi:10.1115/1.4033986 · Cited by 49
Self-citationNumerical investigation of fluid–particle interactions for embolic stroke
Mukherjee, D., Padilla, J. F., & Shadden, S. C. (2015) · Theoretical and Computational Fluid Dynamics · doi:10.1007/s00162-015-0359-4 · Cited by 43
Self-citationKung, E. O., Kahn, A. M., Burns, J. C., & Marsden, A. L. (2014) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-014-0184-8 · Cited by 40
Self-citationWilson, N. M., Arko, F. R., & Taylor, C. A. (2005) · Computer Aided Surgery · doi:10.3109/10929080500230445 · Cited by 24
Self-citation
Research works printed but not linked: 21
- Arzani, A., A. M. Gambaruto, G. Chen, and S. C. Shadden. Lagrangian wall shear stress structures and near wall transport in high schmidt aneurysmal flows. J. Fluid Mech. 790:158–172, 2016. · DOI
- Arzani, A., A. S Les, R. L. Dalman, and S. C. Shadden. Effect of exercise on patient specific abdominal aortic aneurysm flow topology and mixing. Int. J. Numer. Methods Biomed. Eng. 30(2):280–295, 2014. · doi:10.1002/cnm.2601
- Arzani A., and S. C. Shadden. Characterization of the transport topology in patient-specific abdominal aortic aneurysm models. Phys. Fluids (1994-present) (1994), 24(8):081901, 2012. · doi:10.1063/1.4744984
- Bockman, M. D., A. P. Kansagra, S. C. Shadden, E. C. Wong, and A. L. Marsden. Fluid mechanics of mixing in the vertebrobasilar system: Cardiovasc. Eng. Technol. 3(4):450–461, 2012. · doi:10.1007/s13239-012-0112-8
- Bogren, H. G., R. H. Klipstein, D. N. Firmin, R. H. Mohiaddin, S. R. Underwood, R. S. O. Rees, and D. B. Longmore. Quantitation of antegrade and retrograde blood flow in the human aorta by magnetic resonance velocity mapping. Am. Heart J. 117(6):1214–1222, 1989. · doi:10.1016/0002-8703(89)90399-2
- Cheng, C. P., R. J. Herfkens, C. A. Taylor, and J. A. Feinstein. Proximal pulmonary artery blood flow characteristics in healthy subjects measured in an upright posture using MRI: the effects of exercise and age. J. Magn. Resonance Imaging 21(6):752–758, 2005. · doi:10.1002/jmri.20333
- Esmaily-Moghadam, M., T.-Y. Hsia, and A. L. Marsden. The Assisted Bidirectional Glenn: a novel surgical approach for first stage single ventricle heart palliation. J. Thorac. Cardiovasc. Surg. 149(3):699–705, 2015. · doi:10.1016/j.jtcvs.2014.10.035
- Hansen K. B., and S. C. Shadden. A reduced-dimensional model for near-wall transport in cardiovascular flows. Biomech. Model. Mechanobiol. 15(3):713–722, 2016. · DOI
- Lonyai, A., A. M. Dubin, J. A. Feinstein, C. A. Taylor, and S. C. Shadden. New insights into pacemaker lead-induced venous occlusion: Simulation-based investigation of alterations in venous biomechanics. Cardiovasc. Eng. 10(2):84–90, 2010. · doi:10.1007/s10558-010-9096-x
- Lorigo, L. M., O. D. Faugeras, W. E. L. Grimson, R. Keriven, R. Kikinis, A. Nabavi, and C.-F. Westin. Curves: Curve evolution for vessel segmentation. Med. Image Anal. 5(3):195–206, 2001. · doi:10.1016/s1361-8415(01)00040-8
- Marsden, A. L., V. M. Reddy, S. C. Shadden, F. P. Chan, C. A. Taylor, and J. A. Feinstein. A new multiparameter approach to computational simulation for Fontan assessment and redesign. Congenit. Heart Dis. 5(2):104–117, 2010. · doi:10.1111/j.1747-0803.2010.00383.x
- Martin, M. H., J. A. Feinstein, F. P. Chan, A. L. Marsden, W. Yang, and V. M. Reddy. Technical feasibility and intermediate outcomes of a hand-crafted, area-preserving, bifurcated “Y-Graft” Fontan. Thorac. Cardiovasc. Surg. 149(1):247–255, 2015. · doi:10.1016/j.jtcvs.2014.08.058
- Merkow, J., Z. Tu, D. Kriegman, and A. L. Marsden. Structural edge detection for cardiovascular modeling. In: International Conference on Medical Image Computing and Computer-Assisted Intervention, pp. 735–742. Springer, New York, 2015. · doi:10.1007/978-3-319-24574-4_88
- Morgan, V. L., R. J. Roselli, and C. H. Lorenz. Normal three-dimensional pulmonary artery flow determined by phase contrast magnetic resonance imaging. Ann. Biomed. Eng. 26(4):557–566, 1998. · doi:10.1114/1.125
- Perktold, K., M. Hofer, G. Karner, W. Trubel, and H. Schima. Computer simulation of vascular fluid dynamics and mass transport: optimal design of arterial bypass anastomoses. Proc. ECCOMAS 98:484–489, 1998.
- Schiavazzi, D. E., E. O. Kung, A. L. Marsden, C. Baker, G. Pennati, T.-Y. Hsia, A. Hlavacek, A. L. Dorfman and Modeling of Congenital Hearts Alliance (MOCHA) Investigators et al. Hemodynamic effects of left pulmonary artery stenosis after superior cavopulmonary connection: a patient-specific multiscale modeling study. J. Thorac. Cardiovasc. Surg. 149(3):689–696, 2015. · doi:10.1016/j.jtcvs.2014.12.040
- Suh, G. Y., A. S. Les, A. S. Tenforde, S. C. Shadden, R. L. Spilker, J. J. Yeung, C. P. Cheng, R. J. Herfkens, R. L. Dalman, and C. A. Taylor. Quantification of particle residence time in abdominal aortic aneurysms using magnetic resonance imaging and computational fluid dynamics. Ann. Biomed. Eng. 39:864–883, 2011. · DOI
- Tang, B. T., S. S. Pickard, F. P. Chan, P. S. Tsao, C. A. Taylor, and J. A. Feinstein. Wall shear stress is decreased in the pulmonary arteries of patients with pulmonary arterial hypertension: an image-based, computational fluid dynamics study. Pulm. Circ. 2(4):470–476, 2012. · doi:10.4103/2045-8932.105035
- Updegrove, A., N. M. Wilson, and S. C. Shadden. Boolean and smoothing of discrete polygonal surfaces. Adv. Eng. Softw. 95:16–27, 2016. · doi:10.1016/j.advengsoft.2016.01.015
- Wang K. C.Y. Level set methods for computational prototyping with application to hemodynamic modeling. PhD thesis, Stanford University, 2001.
- Zhou, M., O. Sahni, H. J. Kim, C. A. Figueroa, C. A. Taylor, M. S. Shephard, and K. E. Jansen. Cardiovascular flow simulation at extreme scale. Comput. Mech., 46(1):71–82, 2010. · DOI
Cited by
Kupfer, M. E., Lin, W.-H., Ravikumar, V., Qiu, K., Wang, L., Gao, L., Bhuiyan, D. B., Lenz, M., Ai, J., Mahutga, R. R., et al. (2020) · Circulation Research · doi:10.1161/circresaha.119.316155 · Cited by 329
Kadem, M., Garber, L., Abdelkhalek, M., Al-Khazraji, B. K., & Keshavarz-Motamed, Z. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2022.3142058 · Cited by 89
Uncertainty quantification of simulated biomechanical stimuli in coronary artery bypass grafts
Tran, J. S., Schiavazzi, D. E., Kahn, A. M., & Marsden, A. L. (2019) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2018.10.024 · Cited by 37
A Hybrid Experimental-Computational Modeling Framework for Cardiovascular Device Testing
Kung, E., Farahmand, M., & Gupta, A. (2019) · Journal of Biomechanical Engineering · doi:10.1115/1.4042665 · Cited by 28
Gao, H., Zhu, X., & Wang, J.-X. (2020) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2020.113047 · Cited by 27
“, SimVascular [50].”
Metadata
- Authors
- Updegrove, A., Wilson, N. M., Merkow, J., Lan, H., Marsden, A. L., & Shadden, S. C.
- Venue
- Annals of Biomedical Engineering
- Published
- 2016-12-08
- Volume
- 45
- Issue
- 3
- Pages
- 525-541
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2560585316
- Cited by
- 651
- References
- 56
- FWCI
- 11.40
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Funders
- Office of Cyberinfrastructure (1407834, 1562450)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.