Ultrasound Features of Skeletal Muscle Can Predict Kinematics of Upcoming Lower-Limb Motion
The DOI matches its Crossref record; 53 of the 54 references it cites were found in a registry or an index.
Abstract
Seamless integration of lower-limb assistive devices with the human body requires an intuitive human-machine interface, which would benefit from predicting the intent of individuals in advance of the upcoming motion. Ultrasound imaging was recently introduced as an intuitive sensing interface. The objective of the present study was to investigate the predictability of joint kinematics using ultrasound features of the rectus femoris muscle during a non-weight-bearing knee extension/flexion. Motion prediction accuracy was evaluated in 67 ms increments, up to 600 ms in time. Statistical analysis was used to evaluate the feasibility of motion prediction, and the linear mixed-effects model was used to determine a prediction time window where the joint angle prediction error is barely perceivable by the sample population, hence clinically reliable. Surprisingly, statistical tests revealed that the prediction accuracy of the joint angle was more sensitive to temporal shifts than the accuracy of the joint angular velocity prediction. Overall, predictability of the upcoming joint kinematics using ultrasound features of skeletal muscle was confirmed, and a time window for a statistically and clinically reliable prediction was found between 133 and 142 ms. A reliable prediction of user intent may provide the time needed for processing, control planning, and actuation of the assistive devices at critical points during ambulation, contributing to the intuitive behavior of lower-limb assistive devices.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Furthermore, since muscle morphology often precedes and constrains joint movement, ultrasound signals can serve as a key intermediate variable between the muscle and joint levels for decoding movement intent, as validated in joint angle 118-120 and torque estimation [120][121][122] .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [119]
In the citing paper
“Analyze ultrasound echoes to track muscle | morphological dynamics and infer joint | movement 214 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [119]
Citations
Cites
Statistical Methods for Psychology.
Gudgeon, A. C., & Howell, D. C. (1994) · The Statistician · doi:10.2307/2348956 · Cited by 8,278
Gaussian Processes in Machine Learning
Rasmussen, C. E. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-28650-9_4 · Cited by 5,397
Statistical Parametric Mapping: The Analysis of Functional Brain Images
Penny, W. D., Friston, K. J., Ashburner, J., Kiebel, S. J., & Thomas, N. (2007) · UCL Discovery (University College London) · Cited by 3,672
FUNCTIONAL SIGNIFICANCE OF CELL SIZE IN SPINAL MOTONEURONS
Henneman, E., Somjen, G., & Carpenter, D. O. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.3.560 · Cited by 2,294
Data on the distribution of fibre types in thirty-six human muscles
Johnson, M. A., Polgar, J., Weightman, D., & Appleton, D. (1973) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(73)90023-3 · Cited by 2,200
Generalized N-Dimensional Biomechanical Field Analysis Using Statistical Parametric Mapping
Pataky, T. C. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.008 · Cited by 907
Proprioception in the anterior cruciate deficient knee
Barrack, R. L., Skinner, H. B., & Buckley, S. L. (1989) · The American Journal of Sports Medicine · doi:10.1177/036354658901700101 · Cited by 545
THE INTERNATIONAL CONFERENCE ON HARMONIZATION GOOD CLINICAL PRACTICE GUIDELINE
Dixon, J. R. (1999) · Quality Assurance · doi:10.1080/105294199277860 · Cited by 504
Hagberg, K., & Brånemark, R. (2001) · Prosthetics & Orthotics International · doi:10.1080/03093640108726601 · Cited by 446
Smith, L. H., Hargrove, L. J., Lock, B. A., & Kuiken, T. A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2100828 · Cited by 443
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Proprioception of the knee before and after anterior cruciate ligament reconstruction
Reider, B., Arcand, M. A., Diehl, L. H., Mroczek, K., Abulencia, A., Stroud, C. C., Palm, M., Gilbertson, J., & Staszak, P. (2003) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2003.50006 · Cited by 260
Muscle architecture and function in humans
Fukunaga, T., Kawakami, Y., Kuno, S., Funato, K., & Fukashiro, S. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00171-6 · Cited by 246
Variability of fiber type distributions within human muscles
Elder, G. C., Bradbury, K., & Roberts, R. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.6.1473 · Cited by 224
Real-Time Classification of Hand Motions Using Ultrasound Imaging of Forearm Muscles
Akhlaghi, N., Baker, C. A., Lahlou, M., Zafar, H., Murthy, K. G., Rangwala, H., Košecká, J., Joiner, W. M., Pancrazio, J. J., & Sikdar, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2498124 · Cited by 164
Lack of correlation between different measurements of proprioception in the knee
Grob, K. R., Kuster, M. S., Higgins, S. A., Lloyd, D. G., & Yata, H. (2002) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.84b4.11241 · Cited by 152
Muscle fibre recruitment can respond to the mechanics of the muscle contraction
Wakeling, J. M., Uehli, K., & Rozitis, A. I. (2006) · Journal of The Royal Society Interface · doi:10.1098/rsif.2006.0113 · Cited by 146
Motor unit recruitment for dynamic tasks: current understanding and future directions
Hodson-Tole, E. F., & Wakeling, J. M. (2009) · Journal of Comparative Physiology B · doi:10.1007/s00360-008-0289-1 · Cited by 145
Pandey, N. O., Chauhan, A. V., Raithatha, N. S., Patel, P. K., Khandelwal, R., Desai, A. N., Choxi, Y., Kapadia, R. S., & Jain, N. D. (2019) · Scientific Reports · doi:10.1038/s41598-019-55122-w · Cited by 138
A review on linear mixed models for longitudinal data, possibly subject to dropout
Molenberghs, G., & Verbeke, G. (2001) · Statistical Modelling · doi:10.1177/1471082x0100100402 · Cited by 126
Dhawan, A. S., Mukherjee, B., Patwardhan, S., Akhlaghi, N., Diao, G., Levay, G., Holley, R., Joiner, W. M., Harris-Love, M., & Sikdar, S. (2019) · Scientific Reports · doi:10.1038/s41598-019-45459-7 · Cited by 106
Begovic, H., Zhou, G., Li, T., Wang, Y., & Zheng, Y. (2014) · Frontiers in Physiology · doi:10.3389/fphys.2014.00494 · Cited by 102
Detection of the onset of gait initiation using kinematic sensors and EMG in transfemoral amputees
Wentink, E. C., Schut, V. G. H., Prinsen, E. C., Rietman, J. S., & Veltink, P. H. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.08.008 · Cited by 92
Motor units are recruited in a task-dependent fashion during locomotion
Wakeling, J. M. (2004) · Journal of Experimental Biology · doi:10.1242/jeb.01223 · Cited by 90
Myotendinous junctions of tonic muscle cells: structure and loading
Tidball, J. G., & Daniel, T. (1986) · Cell and Tissue Research · doi:10.1007/bf00213937 · Cited by 90
Gerardo, C. D., Cretu, E., & Rohling, R. N. (2018) · Microsystems & Nanoengineering · doi:10.1038/s41378-018-0022-5 · Cited by 89
Test-retest reliability of knee kinesthesia in healthy adults
Ageberg, E., Flenhagen, J., & Ljung, J. (2007) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-8-57 · Cited by 88
Dynamic imaging of skeletal muscle contraction in three orthogonal directions
Lopata, R. G. P., van Dijk, J. P., Pillen, S., Nillesen, M. M., Maas, H., THIJSSEN, J. M., Stegeman, D. F., & de Korte, C. L. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00092.2010 · Cited by 88
The Promise of Assistive Technology to Enhance Activity and Work Participation
Board on Health Care Services, Division, H. A. M., & National Academies of Sciences, E. (2017) · National Academies Press eBooks · doi:10.17226/24740 · Cited by 87
Intention detection of gait initiation using EMG and kinematic data
Wentink, E. C., Beijen, S. I., Hermens, H. J., Rietman, J. S., & Veltink, P. H. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.07.013 · Cited by 86
A Comparison of Control Strategies in Commercial and Research Knee Prostheses
Fluit, R., Prinsen, E. C., Wang, S., & van der Kooij, H. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2912466 · Cited by 81
Comparative Analysis of Wearable A-Mode Ultrasound and sEMG for Muscle-Computer Interface
Yang, X., Yan, J., & Liu, H. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2962499 · Cited by 81
He, J., Luo, H., Jia, J., Yeow, J. T. W., & Jiang, N. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2872593 · Cited by 80
Dieterich, A. V., Botter, A., Vieira, T., Peolsson, A. L. C., Petzke, F. W., Davey, P. C., & Falla, D. (2017) · Scientific Reports · doi:10.1038/srep42011 · Cited by 76
Simon, A. M., Ingraham, K. A., Spanias, J. A., Young, A. J., Finucane, S. B., Halsne, E. G., & Hargrove, L. J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2613020 · Cited by 73
Prediction of Ankle Dorsiflexion Moment by Combined Ultrasound Sonography and Electromyography
Zhang, Q., Kim, K., & Sharma, N. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2953588 · Cited by 69
Lower Limb Motion Estimation Using Ultrasound Imaging: A Framework for Assistive Device Control
Jahanandish, M. H., Fey, N. P., & Hoyt, K. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2891997 · Cited by 65
Self-citationPrediction of Individual Finger Forces Based on Decoded Motoneuron Activities
Dai, C., Cao, Y., & Hu, X. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02240-1 · Cited by 49
AlMohimeed, I., & Ono, Y. (2020) · Sensors · doi:10.3390/s20133616 · Cited by 47
Marcucci, L., Bondì, M., Randazzo, G., Reggiani, C., NATALI, A. N., & Pavan, P. G. (2019) · PLoS ONE · doi:10.1371/journal.pone.0224232 · Cited by 46
Farmer, S., Silver-Thorn, B., Voglewede, P. A., & Beardsley, S. A. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056027 · Cited by 44
Rehabilitation Engineering: A perspective on the past 40-years and thoughts for the future
Cooper, R. A., & Cooper, R. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.08.011 · Cited by 44
Li, J., Kong, F., Gao, X., Shen, Y., & Gao, S. (2016) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2016.04.024 · Cited by 39
Investigation of Timing to Switch Control Mode in Powered Knee Prostheses during Task Transitions
Zhang, F., Liu, M., & Huang, H. (2015) · PLoS ONE · doi:10.1371/journal.pone.0133965 · Cited by 38
M-mode ultrasound used to detect the onset of deep muscle activity
Dieterich, A. V., Pickard, C. M., Deshon, L. E., Strauss, G. R., Gibson, W., Davey, P. C., & McKay, J. C. (2015) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2014.12.006 · Cited by 33
Lower limb active prosthetic systems—overview
Voloshina, A. S., & Collins, S. H. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814659-0.00023-0 · Cited by 33
sEMG Based Gait Phase Recognition for Children with Spastic Cerebral Palsy
Wei, P.-N., Xie, R., Tang, R., Li, C., Kim, J., & Wu, M. (2018) · Annals of Biomedical Engineering · doi:10.1007/s10439-018-02126-8 · Cited by 29
Recurrent Neural Network Based Early Prediction of Future Hand Movements
Koch, P., Phan, H., Maaß, M., Katzberg, F., & Mertins, A. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513145 · Cited by 24
Qiu, S., Feng, J., Xu, J., Xu, R., Zhao, X., Zhou, P., Qi, H., Zhang, L., & Ming, D. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2556687 · Cited by 15
Rabe, K. G., Jahanandish, M. H., Hoyt, K., & Fey, N. P. (2020) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob49111.2020.9224465 · Cited by 13
Self-citationUse of Sonomyographic Sensing to Estimate Knee Angular Velocity During Varying Modes of Ambulation
Rabe, K. G., Jahanandish, M. H., Hoyt, K., & Fey, N. P. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176674 · Cited by 10
Self-citationJahanandish, M. H., Rabe, K. G., Fey, N. P., & Hoyt, K. (2019) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2019.8779534 · Cited by 9
Self-citationPrediction of Distal Lower-Limb Motion Using Ultrasound-Derived Features of Proximal Skeletal Muscle
Jahanandish, M. H., Fey, N. P., & Hoyt, K. (2019) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2019.8779360 · Cited by 5
Self-citation
Cited by
Dynamic Gesture Recognition of A-Mode Ultrasonic Based on the DTW Algorithm
Cai, S., Lu, Z., Chen, B., Guo, L., Qing, Z., & Yao, L. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3194272 · Cited by 39
“In the past ten years, there has been much research on gesture recognition of B-mode ultrasonic technology [23]–[25].”
BackgroundMethodUltrasound as a Neurorobotic Interface: A Review
Yang, X., Castellini, C., Farina, D., & Liu, H. (2024) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2024.3358960 · Cited by 33
“Moreover, they found that ultrasound features of skeletal muscles can predict upcoming kinematics approximately 133–142 ms before the movements [96], [97].”
BackgroundHow to Achieve Human–Machine Interaction by Foot Gesture Recognition: A Review
Lian, Y., Lu, Z., Dong, H., Chao, J., Ziqiang, L., & Zhoujie, L. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3285214 · Cited by 36
Zhang, Q., Iyer, A., Sun, Z., Kim, K., & Sharma, N. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3106900 · Cited by 30
The LET Procedure for Gesture Recognition With Multiple Forearm Angles
Cai, S., Lu, Z., Guo, L., Qing, Z., & Yao, L. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3177475 · Cited by 23
Metadata
- Authors
- Jahanandish, M. H., Rabe, K. G., Fey, N. P., & Hoyt, K.
- Affiliations
- The University of Texas at Dallas (US)
- Corresponding author
- Fey, Nicholas P.
- Hoyt, Kenneth
- Venue
- Annals of Biomedical Engineering
- Published
- 2020-09-21
- Volume
- 49
- Issue
- 2
- Pages
- 822-833
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W3087175300
- Cited by
- 23
- References
- 54
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 2 · 2023: 5 · 2022: 5 · 2021: 5
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Annals of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (1925343)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Keywords
- ultrasonography, skeletal muscle, rectus femoris, motion prediction, lower-limb assistive devices, human-machine interaction, linear mixed models, joint angles, joint angular velocity
- MeSH terms
- Adolescent, Adult, Biomechanical Phenomena, Female, Humans, Knee Joint, Male, Movement, Ultrasonography, Range of Motion, Articular, Muscle, Skeletal, Lower Extremity, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.