OptCoNet: an optimized convolutional neural network for an automatic diagnosis of COVID-19
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The quick spread of coronavirus disease (COVID-19) has become a global concern and affected more than 15 million confirmed patients as of July 2020. To combat this spread, clinical imaging, for example, X-ray images, can be utilized for diagnosis. Automatic identification software tools are essential to facilitate the screening of COVID-19 using X-ray images. This paper aims to classify COVID-19, normal, and pneumonia patients from chest X-ray images. As such, an Optimized Convolutional Neural network (OptCoNet) is proposed in this work for the automatic diagnosis of COVID-19. The proposed OptCoNet architecture is composed of optimized feature extraction and classification components. The Grey Wolf Optimizer (GWO) algorithm is used to optimize the hyperparameters for training the CNN layers. The proposed model is tested and compared with different classification strategies utilizing an openly accessible dataset of COVID-19, normal, and pneumonia images. The presented optimized CNN model provides accuracy, sensitivity, specificity, precision, and F1 score values of 97.78%, 97.75%, 96.25%, 92.88%, and 95.25%, respectively, which are better than those of state-of-the-art models. This proposed CNN model can help in the automatic screening of COVID-19 patients and decrease the burden on medicinal services frameworks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Holland, J. H. (1992) · Scientific American · doi:10.1038/scientificamerican0792-66 · Cited by 5,764
Apostolopoulos, I. D., & Mpesiana, T. A. (2020) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-020-00865-4 · Cited by 2,338
Narin, A., Kaya, C., & Pamuk, Z. (2021) · Pattern Analysis and Applications · doi:10.1007/s10044-021-00984-y · Cited by 2,054 · cited 3×
“Consequently, no tuning is needed for different databases, as opposed to other model-based methodologies, as in [8, 14].”
BackgroundMethodLi, L., Qin, L., Xu, Z., Yin, Y., Wang, X., Kong, B., Bai, J., Lu, Y., Fang, Z., Song, Q., et al. (2020) · Radiology · doi:10.1148/radiol.2020200905 · Cited by 1,927
Cited by
Kaveh, M., & Mesgari, M. S. (2023) · Neural Processing Letters · doi:10.1007/s11063-022-11055-6 · Cited by 292
Park, J., Kwak, I.-Y., & Lim, C. (2021) · Electronics · doi:10.3390/electronics10161996 · Cited by 24
“[62] aimed to classify COVID-19, normal and pneumonia using CXR images.”
Method
Metadata
- Authors
- Goel, T., Murugan, R., Mirjalili, S., & Chakrabartty, D. K.
- Venue
- Applied Intelligence
- Published
- 2020-09-21
- Volume
- 51
- Issue
- 3
- Pages
- 1351-1366
- ISSN
- 0924-669X (ISSN-L)
- 1573-7497
- OpenAlex
- W3087300877
- Cited by
- 177
- References
- 4
- FWCI
- 14.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: OptCoNet: an optimized convolutional neural network for an automatic diagnosis of COVID-19. https://app.cochat.ai/papers/10.1007/s10489-020-01904-z
- The paper
- Goel, T., Murugan, R., Mirjalili, S., & Chakrabartty, D. K. (2021). OptCoNet: an optimized convolutional neural network for an automatic diagnosis of COVID-19. Applied Intelligence. https://doi.org/10.1007/s10489-020-01904-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.