In vitro blood flow in a rectangular PDMS microchannel: experimental observations using a confocal micro-PIV system
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288 · cited 1×
“…useful properties, including good optical transparency and biocompatibility, easily reversible sealing to glass, elasticity, replication of fine and complex geometries, permeability to gases, thermal stability, and low cost (Duffy et al. 1998; Chang et al. 2003; Mata et al. 2005; Kaji et al. 2006).”
BackgroundParticle Image Velocimetry: A Practical Guide
Raffel, M., Willert, C. E., Scarano, F., Kähler, C. J., Wereley, S. T., & Kompenhans, J. (2018) · doi:10.1007/978-3-319-68852-7 · Cited by 5,049
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010 · cited 2×
“The UTS and E of blood vessels have values from 0.4 to 1.4 MPa (Holzapfel et al. 2005) and ∼2.5 MPa (Steiger et al. 1989), respectively.”
BackgroundInfluentialParticle-Imaging Techniques for Experimental Fluid Mechanics
Adrian, R. J. (1991) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.23.010191.001401 · Cited by 3,405 · cited 1×
“…because of advances in computers, optics, and digital image processing techniques, it has become possible to combine a conventional particle image velocimetry (PIV) system (Adrian 1991; Raffel et al. 1998) with an inverted epifluorescent microscope (Santiago et al. 1998; Koutsiaris et al. 1999).”
MethodPoly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800 · cited 2×
“…microchannels may not be the best models to simulate the geometry of microvessels in vivo, many aspects of blood flow behavior through this kind of microchannel are similar to those in living microvessels (Beebe et al. 2002; Shevkoplyas et al. 2003; Toner and Irimia 2005; Faivre et al. 2006).”
BackgroundRaffel, M., Willert, C. E., & Kompenhans, J. (1998) · Springer eBooks · doi:10.1007/978-3-662-03637-2 · Cited by 1,371
Characterization of Polydimethylsiloxane (PDMS) Properties for Biomedical Micro/Nanosystems
Mata, A., Fleischman, A. J., & Roy, S. (2005) · Biomedical Microdevices · doi:10.1007/s10544-005-6070-2 · Cited by 1,318 · cited 3×
“The UTS and E of blood vessels have values from 0.4 to 1.4 MPa (Holzapfel et al. 2005) and ∼2.5 MPa (Steiger et al. 1989), respectively.”
BackgroundInfluentialTHE VISCOSITY OF THE BLOOD IN NARROW CAPILLARY TUBES
Fåhræus, R., & Lindqvist, T. (1931) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1931.96.3.562 · Cited by 1,268
Cited by
Properties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 824
Self-citationMicro-Particle Image Velocimetry (µPIV): Recent developments, applications, and guidelines
Lindken, R., Rossi, M., Große, S., & Westerweel, J. (2009) · Lab on a Chip · doi:10.1039/b906558j · Cited by 387
Quantitative Analysis of Molecular Absorption into PDMS Microfluidic Channels
Wang, J. D., Douville, N. J., Takayama, S., & ElSayed, M. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0562-z · Cited by 265
Passive blood plasma separation at the microscale: a review of design principles and microdevices
Tripathi, S., Varun Kumar, Y. V. B., Prabhakar, A., Joshi, S. S., & Agrawal, A. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/8/083001 · Cited by 223
“One such study is by Lima et al [51, 131], who studied blood flow behavior in a rectangular PDMS microchannel.”
BackgroundXing, H. Z., Zhang, Q. B., Braithwaite, C. H., Pan, B., & Zhao, J. (2017) · Rock Mechanics and Rock Engineering · doi:10.1007/s00603-016-1164-0 · Cited by 174
Study of PDMS characterization and its applications in biomedicine: A review
Apolónia, S., Victor, A., Bragança, Portugal, andrews.va.souza@alunos.ipb.pt, Ribeiro, J., jribeiro@ipb.pt, C. S. A., F. Araújo, F., & fernando.araujo@cefet-rj.br, C. C. A. D. R. D. J. (2019) · Journal of Mechanical Engineering and Biomechanics · doi:10.24243/jmeb/4.1.163 · Cited by 173
“With the development of technology and of behavioural studies and their characteristics, PDMS has been gaining new applications in micro and nanotechnology, and in the study of the biophysical behaviour of blood flow in microvessels [11].”
BackgroundA circular cross-section PDMS microfluidics system for replication of cardiovascular flow conditions
Fiddes, L. K., Raz, N., Srigunapalan, S., Tumarkan, E., Simmons, C. A., Wheeler, A. R., & Kumacheva, E. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.082 · Cited by 170
Pamies, D., Ekert, J., Zurich, M.-G., Frey, O., Werner, S., Piergiovanni, M., Freedman, B. S., Keong Teo, A. K., Erfurth, H., Reyes, D. R., et al. (2024) · Stem Cell Reports · doi:10.1016/j.stemcr.2024.03.009 · Cited by 88
Metadata
- Authors
- Lima, R., Wada, S., Tanaka, S., Takeda, M., Ishikawa, T., Tsubota, K.-I., Imai, Y., & Yamaguchi, T.
- Venue
- Biomedical Microdevices
- Published
- 2007-09-18
- Volume
- 10
- Issue
- 2
- Pages
- 153-167
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2089145587
- Cited by
- 201
- References
- 37
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.