The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Study of PDMS characterization and its applications in biomedicine: A review
Open accessAbstract
Polydimethylsiloxane, also known as PDMS, has been widely used in the biomedical industry because of its biocompatible material and its biomechanical behavior is similar to biological tissues, with applications in the study of aneurysmal behavior and devices such as: Micro pumps, optical systems, microfluidic circuits. Many advances in research have been reached, but further tests are still necessary to understand the mechanical behavior and applicability of the material. For the study of PDMS behavior, two different techniques are employed: numerical and experimental. In experimental studies, it is extremely popular to use a field technique, in which the most appropriate technique to measure the field displacement of PDMS, without decorrelation, is the Digital Image Correlation (DIC) method. In this paper, we revised the most important experimental works with PDMS material and, simultaneously, we present its mechanical properties and its biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Klinge, P. M., Vafa, M. A., Brinker, T., Brandis, A., Walter, G. F., Stieglitz, T., Samii, M., & Wewetzer, K. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00420-8 · Cited by 64
Cited by
Properties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 824
Self-citationPolydimethylsiloxane Composites Characterization and Its Applications: A Review
Ariati, R., Sales, F., Souza, A., Lima, R. A., & Ribeiro, J. (2021) · Polymers · doi:10.3390/polym13234258 · Cited by 440
Self-citation
Metadata
- Authors
- Apolónia, S., Victor, A., Bragança, Portugal, andrews.va.souza@alunos.ipb.pt, Ribeiro, J., jribeiro@ipb.pt, C. S. A., F. Araújo, F., & fernando.araujo@cefet-rj.br, C. C. A. D. R. D. J.
- Venue
- Journal of Mechanical Engineering and Biomechanics
- Publisher
- Rational Publication
- Published
- 2019-08-10
- Volume
- 4
- Issue
- 1
- Pages
- 1-9
- ISSN
- 2456-219X (ISSN-L)
- OpenAlex
- W2967780747
- Cited by
- 173
- References
- 3
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Study of PDMS characterization and its applications in biomedicine: A review. https://app.cochat.ai/papers/10.24243/jmeb/4.1.163
- The paper
- Apolónia, S., Victor, A., Bragança, Portugal, andrews.va.souza@alunos.ipb.pt, Ribeiro, J., jribeiro@ipb.pt, C. S. A., F. Araújo, F., & fernando.araujo@cefet-rj.br, C. C. A. D. R. D. J. (2019). Study of PDMS characterization and its applications in biomedicine: A review. Journal of Mechanical Engineering and Biomechanics. https://doi.org/10.24243/jmeb/4.1.163
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.