A passive MEMS drug delivery pump for treatment of ocular diseases
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288 · cited 1×
“The entire assembly was then baked at 100°C for 45 min in order to complete the bonding process (Duffy et al. 1998).”
MethodMonolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010 · cited 1×
“The final structure was mechanically-reinforced by applying a thin PDMS layer around the perimeter of the device (Unger et al. 2000; Wu et al. 2005).”
MethodFabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329 · cited 2×
“The bonding surfaces were treated by exposure to oxygen plasma (DP80M RIE, Plasma Technology LTD, United Kingdom); 100 W and 100 mTorr for 45 s. Oxygen plasma treatment enables the formation of irreversible bonds between separate PDMS pieces (McDonald et al. 2000).”
BackgroundMethodPoly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454 · cited 2×
“Ethanol was used to extend the lifetime of the oxygen plasma modified surface and to lubricate the layers during alignment (McDonald and Whitesides 2002).”
BackgroundMethodA controlled-release microchip
Santini, J. T., Cima, M. J., & Langer, R. (1999) · Nature · doi:10.1038/16898 · Cited by 868 · cited 1×
“Microreservoirs provide the greatest delivery control of the three methods (Santini et al. 1999).”
MethodEncyclopedia of Biomaterials and Biomedical Engineering
(2008) · CRC Press eBooks · doi:10.1201/9780429154065 · Cited by 700 · cited 1×
“Intraocular injections can directly bypass physiological barriers, however, the limited half-life of drugs in the vitreous cavity necessitates frequent injections (as many as 1-3 per week) for disease management (Lee et al. 2004).”
BackgroundZiaie, B. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.09.001 · Cited by 456 · cited 1×
“…pump systems have been successfully executed for other drug delivery needs (e.g. insulin delivery, neurological compounds) (Grayson et al. 2004; Razzacki et al. 2004; Ziaie et al. 2004), due to ocular space limitations, currently available commercial devices are unsuitable for ocular drug delivery.”
BackgroundTherapeutic applications of implantable drug delivery systems
Dash, A., & Cudworth, G. (1998) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/s1056-8719(98)00027-6 · Cited by 358 · cited 2×
“Atypical systems provide targeted delivery at a constant rate and minimizes the drug volume required for treatment (Dash and Cudworth 1998).”
BackgroundCao, L., Mantell, S., & Polla, D. (2001) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00680-x · Cited by 186 · cited 1×
“Micropumps have been fabricated to provide controlled drug delivery via active pumping (Cao et al. 2001).”
BackgroundSmerdon, D. (2000) · Current Anaesthesia & Critical Care · doi:10.1054/cacc.2000.0296 · Cited by 161 · cited 2×
“The medial wall of the orbit is only 7 mm from the globe (Smerdon 2000).”
Background
Cited by
Polymeric Biomaterials for Medical Implants and Devices
Teo, A. J. T., Mishra, A., Park, I., Kim, Y.-J., Park, W.-T., & Yoon, Y.-J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00429 · Cited by 778
Microneedles: an emerging transdermal drug delivery system
Bariya, S. H., Gohel, M. C., Mehta, T. A., & Sharma, O. P. (2012) · Journal of Pharmacy and Pharmacology · doi:10.1111/j.2042-7158.2011.01369.x · Cited by 455
Drug delivery systems for programmed and on-demand release
Davoodi, P., Lee, L. Y., Xu, Q., Sunil, V., Sun, Y., Soh, S., & Wang, C.-H. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.07.002 · Cited by 353
Nanomedicines for back of the eye drug delivery, gene delivery, and imaging
Kompella, U. B., Amrite, A. C., Pacha Ravi, R., & Durazo, S. A. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.04.001 · Cited by 258
Microfluidics for advanced drug delivery systems
Riahi, R., Tamayol, A., Shaegh, S. A. M., Ghaemmaghami, A. M., Dokmeci, M. R., & Khademhosseini, A. (2015) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2014.12.001 · Cited by 254
Reservoir-based drug delivery systems utilizing microtechnology
Stevenson, C. L., Santini, J. T., & Langer, R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.02.005 · Cited by 250
“Such a system was designed for the treatment of glaucoma, agerelated macular degeneration, and diabetic retinopathy [44,83].”
BackgroundPrinciples of pharmacology in the eye
Awwad, S., Mohamed Ahmed, A. H. A., Sharma, G., Heng, J. S., Khaw, P. T., Brocchini, S., & Lockwood, A. (2017) · British Journal of Pharmacology · doi:10.1111/bph.14024 · Cited by 224
“This device was tested in vivo on rabbits using phenylephrine as a model drug (Lo et al., 2009).”
Wireless on-demand drug delivery
Mirvakili, S. M., & Langer, R. (2021) · Nature Electronics · doi:10.1038/s41928-021-00614-9 · Cited by 202
Ophthalmic gels: Past, present and future
Al-Kinani, A. A., Zidan, G., Elsaid, N., Seyfoddin, A., Alani, A. W. G., & Alany, R. G. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.12.017 · Cited by 194
“These MEMS devices have the advantage of controlled drug delivery rates despite their small size due to absence of the mechanical pump that is present in conventional pump systems [240].”
Wearable Skin Sensors and Their Challenges: A Review of Transdermal, Optical, and Mechanical Sensors
Ahmad Tarar, A., Mohammad, U., & K. Srivastava, S. (2020) · Biosensors · doi:10.3390/bios10060056 · Cited by 119
“Implantable devices have actually been used since the 1950s, when the first pacemaker was used to restore a normal heart rate by continuously pulsing only the ventricle [4]; then the evolution of implantable technology began leading to most recent implants such as Ocular and Cochlear implants [5–7].”
Method
Metadata
- Authors
- Lo, R., Li, P.-Y., Saati, S., Agrawal, R. N., Humayun, M. S., & Meng, E.
- Venue
- Biomedical Microdevices
- Published
- 2009-04-25
- Volume
- 11
- Issue
- 5
- Pages
- 959-970
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2001558005
- Cited by
- 158
- References
- 14
- FWCI
- 5.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.