The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Reservoir-based drug delivery systems utilizing microtechnology
Open accessAbstract
This review covers reservoir-based drug delivery systems that incorporate microtechnology, with an emphasis on oral, dermal, and implantable systems. Key features of each technology are highlighted such as working principles, fabrication methods, dimensional constraints, and performance criteria. Reservoir-based systems include a subset of microfabricated drug delivery systems and provide unique advantages. Reservoirs, whether external to the body or implanted, provide a well-controlled environment for a drug formulation, allowing increased drug stability and prolonged delivery times. Reservoir systems have the flexibility to accommodate various delivery schemes, including zero order, pulsatile, and on demand dosing, as opposed to a standard sustained release profile. Furthermore, the development of reservoir-based systems for targeted delivery for difficult to treat applications (e.g., ocular) has resulted in potential platforms for patient therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Multi-pulse drug delivery from a resorbable polymeric microchip device
Grayson, A. C. R., Choi, I. S., Tyler, B. M., Wang, P. P., Brem, H., Cima, M. J., & Langer, R. (2003) · Nature Materials · doi:10.1038/nmat998 · Cited by 444
Self-citationSilicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413
Suprachoroidal drug delivery to the back of the eye using hollow microneedles
Patel, S. R., Lin, A. S. P., Edelhauser, H. F., & Prausnitz, M. R. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0271-y · Cited by 330
Cited by
Emerging micro- and nanotechnology based synthetic approaches for insulin delivery
Mo, R., Jiang, T., Di, J., Tai, W., & Gu, Z. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60436e · Cited by 386
Recent advances of controlled drug delivery using microfluidic platforms
Sanjay, S. T., Zhou, W., Dou, M., Tavakoli, H., Ma, L., Xu, F., & Li, X. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.09.013 · Cited by 365
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
Leveraging Physiology for Precision Drug Delivery
Sun, W., Hu, Q., Ji, W., Wright, G., & Gu, Z. (2017) · Physiological Reviews · doi:10.1152/physrev.00015.2016 · Cited by 169
Metadata
- Authors
- Stevenson, C. L., Santini, J. T., & Langer, R.
- Venue
- Advanced Drug Delivery Reviews
- Publisher
- Elsevier BV
- Published
- 2012-11
- Volume
- 64
- Issue
- 14
- Pages
- 1590-1602
- ISSN
- 0169-409X (ISSN-L)
- OpenAlex
- W2056647619
- Cited by
- 250
- References
- 4
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reservoir-based drug delivery systems utilizing microtechnology. https://app.cochat.ai/papers/10.1016/j.addr.2012.02.005
- The paper
- Stevenson, C. L., Santini, J. T., & Langer, R. (2012). Reservoir-based drug delivery systems utilizing microtechnology. Advanced Drug Delivery Reviews. https://doi.org/10.1016/j.addr.2012.02.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.