Design and development of microbioreactors for long-term cell culture in controlled oxygen microenvironments
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
The ability to control the oxygen level to which cells are exposed in tissue culture experiments is crucial for many applications. Here, we design, develop and test a microbioreactor (MBR) for long-term cell culture studies with the capability to accurately control and continuously monitor the dissolved oxygen (DO) level in the cell microenvironment. In addition, the DO level can be controlled independently from other cues, such as the viscous shear-stress acting on the cells. We first analyze the transport of oxygen in the proposed device and determine the materials and dimensions that are compatible with uniform oxygen tension and low shear-stress at the cell level. The device is also designed to culture a statistically significant number of cells. We use fully transparent materials and the overall design of the device is compatible with live-cell imaging. The proposed system includes real-time read-out of actual DO levels, is simple to fabricate at low cost, and can be easily expanded to control the concentration of other microenvironmental solutes. We performed control experiments in the absence of cells to demonstrate that the MBR can be used to accurately modulate DO levels ranging from atmospheric level to 1%, both under no flow and perfusion conditions. We also demonstrate cancer cell attachment and viability within the MBR. The proposed MBR offers the unprecedented capability to perform on-line measurement and analysis of DO levels in the microenvironment of adherent…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Most of them control the oxygen levels in culture chambers and can be categorized into three groups; introducing oxygen scavenging chemicals [210, 211], gas supply channels adjacent to the cell chamber [212] and oxygen impermeable materials [213, 214].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [213]
Citations
Cites
Low Reynolds Number Hydrodynamics
Pearson, J. R. A. (1966) · Chemical Engineering Science · doi:10.1016/0009-2509(66)85045-5 · Cited by 1,671
Low Reynolds number hydrodynamics: with special applications to particulate media
Happel, J., & Brenner, H. (1983) · Mechanics of fluids and transport processes · doi:10.1007/978-94-009-8352-6 · Cited by 1,354
Distribution of hematopoietic stem cells in the bone marrow according to regional hypoxia
Parmar, K., Mauch, P., Vergilio, J.-A., Sackstein, R., & Down, J. D. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0701152104 · Cited by 867
Low O 2 tensions and the prevention of differentiation of hES cells
Ezashi, T., Das, P., & Roberts, R. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501283102 · Cited by 806
Components for integrated poly(dimethylsiloxane) microfluidic systems
Ng, J. M. K., Gitlin, I., Stroock, A. D., & Whitesides, G. M. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200210)23:20<3461::aid-elps3461>3.0.co;2-8 · Cited by 626
Shweiki, D., Neeman, M., Itin, A., & Keshet, E. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.768 · Cited by 599
脇屋, 正. (1969) · 日本物理學會誌 · Cited by 460
THIN SILICONE MEMBRANES‐THEIR PERMEATION PROPERTIES AND SOME APPLICATIONS
Robb, W. L. (1968) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1968.tb20277.x · Cited by 429
Liver-Specific Functional Studies in a Microfluidic Array of Primary Mammalian Hepatocytes
Kane, B. J., Zinner, M. J., Yarmush, M. L., & Toner, M. (2006) · Analytical Chemistry · doi:10.1021/ac051856v · Cited by 264
Akimoto, S., Mitsumata, M., Sasaguri, T., & Yoshida, Y. (2000) · Circulation Research · doi:10.1161/01.res.86.2.185 · Cited by 260
Microfluidic PDMS (Polydimethylsiloxane) Bioreactor for Large-Scale Culture of Hepatocytes
Leclerc, E., Sakai, Y., & Fujii, T. (2004) · Biotechnology Progress · doi:10.1021/bp0300568 · Cited by 234
Mehta, G., Mehta, K., Sud, D., Song, J. W., Bersano-Begey, T., Futai, N., Heo, Y. S., Mycek, M.-A., Linderman, J. J., & Takayama, S. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9005-7 · Cited by 231
The effect of actin disrupting agents on contact guidance of human embryonic stem cells
Gerecht, S., Bettinger, C. J., Zhang, Z., Borenstein, J. T., Vunjak-Novakovic, G., & Langer, R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.05.027 · Cited by 228
Self-citationNiebruegge, S., Bauwens, C. L., Peerani, R., Thavandiran, N., Masse, S., Sevaptisidis, E., Nanthakumar, K., Woodhouse, K., Husain, M., Kumacheva, E., et al. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22065 · Cited by 222
Angiogenesis and rheumatoid arthritis: pathogenic and therapeutic implications.
Colville-Nash, P. R., & Scott, D. L. (1992) · Annals of the Rheumatic Diseases · doi:10.1136/ard.51.7.919 · Cited by 213
Enhancement of In Vitro Capillary Tube Formation by Substrate Nanotopography
Bettinger, C. J., Zhang, Z., Gerecht, S., Borenstein, J. T., & Langer, R. (2008) · Advanced Materials · doi:10.1002/adma.200702487 · Cited by 181
Self-citationPolinkovsky, M., Gutierrez, E., Levchenko, A., & Groisman, A. (2009) · Lab on a Chip · doi:10.1039/b816191g · Cited by 136
Oxygen gradients for open well cellular cultures via microfluidic substrates
Lo, J. F., Sinkala, E., & Eddington, D. T. (2010) · Lab on a Chip · doi:10.1039/c004660d · Cited by 127
A novel multishear microdevice for studying cell mechanics
Chau, L., Doran, M., & Cooper-White, J. (2009) · Lab on a Chip · doi:10.1039/b823180j · Cited by 117
Lam, R. H. W., Kim, M.-C., & Thorsen, T. (2009) · Analytical Chemistry · doi:10.1021/ac9006864 · Cited by 104
Abaci, H. E., Truitt, R., Luong, E., Drazer, G., & Gerecht, S. (2010) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00484.2009 · Cited by 101
Self-citationForced Assembly of Polymer Nanolayers Thinner Than the Interphase
Liu, R. Y. F., Ranade, A., Wang, H. P., Bernal‐Lara, T. E., Hiltner, A., & Baer, E. (2005) · Macromolecules · doi:10.1021/ma051649x · Cited by 88
Angiogenesis by transplantation of HIF‐1α modified EPCs into ischemic limbs
Jiang, M., Wang, B., Wang, C., He, B., Fan, H., Guo, T. B., Shao, Q., Gao, L., & Liu, Y. (2007) · Journal of Cellular Biochemistry · doi:10.1002/jcb.21416 · Cited by 84
Effect of Contact Time and Force on Monocyte Adhesion to Vascular Endothelium
Rinker, K. D., Prabhakar, V., & Truskey, G. A. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76143-7 · Cited by 80
Therade-Matharan, S., Laemmel, E., Duranteau, J., & Vicaut, E. (2004) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00048.2004 · Cited by 75
Hasan, N., Adams, G., Joiner, M., Marshall, J., & Hart, I. (1998) · British Journal of Cancer · doi:10.1038/bjc.1998.299 · Cited by 68
Guzzardi, M. A., Vozzi, F., & Ahluwalia, A. D. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0695 · Cited by 62
Abumiya, T., Sasaguri, T., Taba, Y., Miwa, Y., & Miyagi, M. (2002) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.0000018300.43492.83 · Cited by 61
Guiding endothelial progenitor cell tube formation using patterned fibronectin surfaces
Dickinson, L. E., Moura, M., & Gerecht, S. (2010) · Soft Matter · doi:10.1039/c0sm00233j · Cited by 50
Self-citationJiang, M., Wang, B., Wang, C., He, B., Fan, H., Shao, Q., Gao, L., Liu, Y., Yan, G., & Pu, J. (2008) · The International Journal of Biochemistry & Cell Biology · doi:10.1016/j.biocel.2008.03.012 · Cited by 49
Unforeseen decreases in dissolved oxygen levels affect tube formation kinetics in collagen gels
Abaci, H. E., Truitt, R., Tan, S., & Gerecht, S. (2011) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00074.2011 · Cited by 49
Self-citationInvestigation of Oxygen Permeation through Composites of PMMA and Surface‐Modified ZnO Nanoparticles
Hess, S., Demir, M. M., Yakutkin, V. V., Baluschev, S. B., & Wegner, G. (2009) · Macromolecular Rapid Communications · doi:10.1002/marc.200800732 · Cited by 47
Purpura, K. A., George, S. H. L., Dang, S. M., Choi, K., Nagy, A., & Zandstra, P. W. (2008) · Stem Cells · doi:10.1634/stemcells.2008-0237 · Cited by 44
The Niche Regulation of Hematopoietic Stem Cells
Iwasaki, H., & Suda, T. (2009) · Humana Press eBooks · doi:10.1007/978-1-60327-227-8_15 · Cited by 4
Cited by
Biological detection by optical oxygen sensing
Papkovsky, D. B., & Dmitriev, R. I. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60131e · Cited by 444
Moshksayan, K., Kashaninejad, N., Warkiani, M. E., Lock, J. G., Moghadas, H., Firoozabadi, B., Saidi, M. S., & Nguyen, N.-T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.223 · Cited by 267
Abaci, H. E., & Shuler, M. L. (2015) · Integrative Biology · doi:10.1039/c4ib00292j · Cited by 243
Self-citationMicrofluidic modelling of the tumor microenvironment for anti-cancer drug development
Shang, M., Soon, R. H., Lim, C. T., Khoo, B. L., & Han, J. (2019) · Lab on a Chip · doi:10.1039/c8lc00970h · Cited by 227
Microfluidic platforms for cell cultures and investigations
Coluccio, M. L., Perozziello, G., Malara, N., Parrotta, E., Zhang, P., Gentile, F., Limongi, T., Raj, P. M., Cuda, G., Candeloro, P., et al. (2019) · Microelectronic Engineering · doi:10.1016/j.mee.2019.01.004 · Cited by 198
“[118], 1 [125–127] Data acquisition fluid Handling, motion tracking”
Background
Metadata
- Authors
- Abaci, H. E., Devendra, R., Smith, Q., Gerecht, S., & Drazer, G.
- Affiliations
- Johns Hopkins University (US)
- Corresponding author
- Gerecht, Sharon
- Venue
- Biomedical Microdevices
- Published
- 2011-09-27
- Volume
- 14
- Issue
- 1
- Pages
- 145-152
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2072198755
- Cited by
- 67
- References
- 34
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 6 · 2020: 5 · 2019: 7 · 2018: 10 · 2017: 3 · 2016: 4 · 2015: 6 · 2014: 11 · 2013: 7 · 2012: 2
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Biomedical Microdevices (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Institutes of Health
- National Cancer Institute (U54CA143868)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Fluid Dynamics and Mixing
- Keywords
- microbioreactors, dissolved oxygen control, oxygen microenvironment, long-term cell culture, oxygen transport, shear stress, perfusion, live-cell imaging, cell viability, adherent cell culture
- MeSH terms
- Humans, Oxygen, Cell Culture Techniques, Bioreactors, Cellular Microenvironment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.