Culturing Aerobic and Anaerobic Bacteria and Mammalian Cells with a Microfluidic Differential Oxygenator
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this manuscript, we report on the culture of anaerobic and aerobic species within a disposable multilayer polydimethylsiloxane (PDMS) microfluidic device with an integrated differential oxygenator. A gas-filled microchannel network functioning as an oxygen-nitrogen mixer generates differential oxygen concentration. By controlling the relative flow rate of the oxygen and nitrogen input gases, the dissolved oxygen (DO) concentration in proximal microchannels filled with culture media are precisely regulated by molecular diffusion. Sensors consisting of an oxygen-sensitive dye embedded in the fluid channels permit dynamic fluorescence-based monitoring of the DO concentration using low-cost light-emitting diodes. To demonstrate the general utility of the platform for both aerobic and anaerobic culture, three bacteria with differential oxygen requirements (E. coli, A. viscosus, and F. nucleatum), as well as a model mammalian cell line (murine embryonic fibroblast cells (3T3)), were cultured. Growth characteristics of the selected species were analyzed as a function of eight discrete DO concentrations, ranging from 0 ppm (anaerobic) to 42 ppm (fully saturated).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bacterial coaggregation: an integral process in the development of multi-species biofilms
Rickard, A. H., Gilbert, P., High, N. J., Kolenbrander, P. E., & Handley, P. S. (2003) · Trends in Microbiology · doi:10.1016/s0966-842x(02)00034-3 · Cited by 765
Dental Plaque as a Microbial Biofilm
Marsh, P. D. (2004) · Caries Research · doi:10.1159/000077756 · Cited by 763
Cited by
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Biological detection by optical oxygen sensing
Papkovsky, D. B., & Dmitriev, R. I. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60131e · Cited by 444
Oxygen control with microfluidics
Brennan, M. D., Rexius-Hall, M. L., Elgass, L. J., & Eddington, D. T. (2014) · Lab Chip · doi:10.1039/c4lc00853g · Cited by 188
Methods to study the tumor microenvironment under controlled oxygen conditions
Byrne, M. B., Leslie, M. T., Gaskins, H. R., & Kenis, P. J. A. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.09.006 · Cited by 104
Abaci, H. E., Devendra, R., Smith, Q., Gerecht, S., & Drazer, G. (2012) · Biomedical Microdevices · doi:10.1007/s10544-011-9592-9 · Cited by 67
Metadata
- Authors
- Lam, R. H. W., Kim, M.-C., & Thorsen, T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-06-11
- Volume
- 81
- Issue
- 14
- Pages
- 5918-5924
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2092353698
- Cited by
- 104
- References
- 2
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Culturing Aerobic and Anaerobic Bacteria and Mammalian Cells with a Microfluidic Differential Oxygenator. https://app.cochat.ai/papers/10.1021/ac9006864
- The paper
- Lam, R. H. W., Kim, M.-C., & Thorsen, T. (2009). Culturing Aerobic and Anaerobic Bacteria and Mammalian Cells with a Microfluidic Differential Oxygenator. Analytical Chemistry. https://doi.org/10.1021/ac9006864
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.