Volumetric breast density affects performance of digital screening mammography
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
PURPOSE: To determine to what extent automatically measured volumetric mammographic density influences screening performance when using digital mammography (DM). METHODS: We collected a consecutive series of 111,898 DM examinations (2003-2011) from one screening unit of the Dutch biennial screening program (age 50-75 years). Volumetric mammographic density was automatically assessed using Volpara. We determined screening performance measures for four density categories comparable to the American College of Radiology (ACR) breast density categories. RESULTS: Of all the examinations, 21.6% were categorized as density category 1 ('almost entirely fatty') and 41.5, 28.9, and 8.0% as category 2-4 ('extremely dense'), respectively. We identified 667 screen-detected and 234 interval cancers. Interval cancer rates were 0.7, 1.9, 2.9, and 4.4‰ and false positive rates were 11.2, 15.1, 18.2, and 23.8‰ for categories 1-4, respectively (both p-trend < 0.001). The screening sensitivity, calculated as the proportion of screen-detected among the total of screen-detected and interval tumors, was lower in higher density categories: 85.7, 77.6, 69.5, and 61.0% for categories 1-4, respectively (p-trend < 0.001). CONCLUSIONS: Volumetric mammographic density, automatically measured on digital mammograms, impacts screening performance measures along the same patterns as established with ACR breast density categories. Since measuring breast density fully automatically has much higher reproducibility than visual assessment, this automatic method could help with implementing density-based supplemental screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mammographic Density and the Risk and Detection of Breast Cancer
Boyd, N. F., Guo, H., Martin, L. J., Sun, L., Stone, J., Fishell, E., Jong, R. A., Hislop, G., Chiarelli, A., Minkin, S., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa062790 · Cited by 2,478 · cited 1×
“In addition, sensitivity of screening mammography is lower for women with dense breasts, caused by the masking effect of dense (fibroglandular) breast tissue [3, 4].”
Breast Density and Parenchymal Patterns as Markers of Breast Cancer Risk: A Meta-analysis
McCormack, V. A., & dos Santos Silva, I. (2006) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-06-0034 · Cited by 2,143 · cited 1×
“Breast density increases breast cancer risk [1, 2].”
Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening
Pisano, E. D., Gatsonis, C., Hendrick, E., Yaffe, M., Baum, J. K., Acharyya, S., Conant, E. F., Fajardo, L. L., Bassett, L., D'Orsi, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa052911 · Cited by 1,940
Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening
Pisano, E. D., Gatsonis, C., Hendrick, E., Yaffe, M., Baum, J. K., Acharyya, S., Conant, E. F., Fajardo, L. L., Bassett, L., D???Orsi, C., et al. (2006) · Obstetrical & Gynecological Survey · doi:10.1097/01.ogx.0000201894.94616.71 · Cited by 482
Pisano, E. D., Hendrick, R. E., Yaffe, M. J., Baum, J. K., Acharyya, S., Cormack, J. B., Hanna, L. A., Conant, E. F., Fajardo, L. L., Bassett, L. W., et al. (2008) · Radiology · doi:10.1148/radiol.2461070200 · Cited by 464 · cited 3×
“…breast density was visually assessed on digital screening mammograms, also found a negative influence of breast density on screening sensitivity [6–8 , 22 ] a fifth study did not find this Although the results in the above studies are not completely consistent, the majority of them showed that…”
Mammographic density, breast cancer risk and risk prediction
Vachon, C. M., van Gils, C. H., Sellers, T. A., Ghosh, K., Pruthi, S., Brandt, K. R., & Pankratz, V. S. (2007) · Breast Cancer Research · doi:10.1186/bcr1829 · Cited by 346 · cited 1×
“Breast density increases breast cancer risk [1, 2].”
Self-citationIdentifying Women With Dense Breasts at High Risk for Interval Cancer: A Cohort Study
Kerlikowske, K., Zhu, W., Tosteson, A. N. A., Sprague, B. L., Tice, J. A., Lehman, C. D., Miglioretti, D. L., & for the Breast Cancer Surveillance Consortium* (2015) · Annals of Internal Medicine · doi:10.7326/m14-1465 · Cited by 286 · cited 2×
“Similar trends were found in two American studies using BCSC data [7, 31].”
Kerlikowske, K., Hubbard, R. A., Miglioretti, D. L., Geller, B. M., Yankaskas, B. C., Lehman, C. D., Taplin, S. H., Sickles, E. A., & for the Breast Cancer Surveillance Consortium (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00005 · Cited by 268 · cited 2×
“Four other studies where breast density was visually assessed on digital screening mammograms, also found a negative influence of breast density on screening sensitivity [6–8, 22] a fifth study did not find this result [23].”
Ciatto, S., Houssami, N., Apruzzese, A., Bassetti, E., Brancato, B., Carozzi, F., Catarzi, S., Lamberini, M. P., Marcelli, G., Pellizzoni, R., et al. (2005) · The Breast · doi:10.1016/j.breast.2004.12.004 · Cited by 231 · cited 1×
“However, this method has a moderate inter-observer agreement [9–12].”
Nelson, H. D., O'Meara, E. S., Kerlikowske, K., Balch, S., & Miglioretti, D. (2016) · Annals of Internal Medicine · doi:10.7326/m15-0971 · Cited by 202 · cited 1×
“Similar trends were found in two American studies using BCSC data [7, 31].”
Cited by
Supplemental MRI Screening for Women with Extremely Dense Breast Tissue
Bakker, M. F., de Lange, S. V., Pijnappel, R. M., Mann, R. M., Peeters, P. H. M., Monninkhof, E. M., Emaus, M. J., Loo, C. E., Bisschops, R. H. C., Lobbes, M. B. I., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1903986 · Cited by 702
Self-citationMammographic breast density and the risk of breast cancer: A systematic review and meta-analysis
Bodewes, F. T. H., van Asselt, A. A., Dorrius, M. D., Greuter, M. J. W., & de Bock, G. H. (2022) · The Breast · doi:10.1016/j.breast.2022.09.007 · Cited by 237
“It can be questioned whether a two-fold risk is strong enough to advocate breast MRI for women with dense breasts.”
BackgroundInfluentialVeenhuizen, S. G. A., de Lange, S. V., Bakker, M. F., Pijnappel, R. M., Mann, R. M., Monninkhof, E. M., Emaus, M. J., de Koekkoek-Doll, P. K., Bisschops, R. H. C., Lobbes, M. B. I., et al. (2021) · Radiology · doi:10.1148/radiol.2021203633 · Cited by 174
Self-citationPötsch, N., Vatteroni, G., Clauser, P., Helbich, T. H., & Baltzer, P. A. T. (2022) · Radiology · doi:10.1148/radiol.212530 · Cited by 162
Deep Learning for Automated Triaging of 4581 Breast MRI Examinations from the DENSE Trial
Verburg, E., van Gils, C. H., van der Velden, B. H. M., Bakker, M. F., Pijnappel, R. M., Veldhuis, W. B., & Gilhuijs, K. G. A. (2022) · Radiology · doi:10.1148/radiol.2021203960 · Cited by 73
Self-citation
Metadata
- Authors
- Wanders, J. O. P., Holland, K., Veldhuis, W. B., Mann, R. M., Pijnappel, R. M., Peeters, P. H. M., van Gils, C. H., & Karssemeijer, N.
- Venue
- Breast Cancer Research and Treatment
- Published
- 2016-12-23
- Volume
- 162
- Issue
- 1
- Pages
- 95-103
- ISSN
- 0167-6806 (ISSN-L)
- 1573-7217
- OpenAlex
- W2567186731
- Cited by
- 166
- References
- 20
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.