Cited by 21Terahertz technology and applicationsAdvanced optical system designSpectroscopy and Laser Applications

Optimum Optical Designs for Diffraction-Limited Terahertz Spectroscopy and Imaging Systems Using Off-Axis Parabolic Mirrors

Open access
Chopra, Nishtha, Lloyd-Hughes, James·2023·Journal of Infrared, Millimeter, and Terahertz Waves

Abstract

Off-axis parabolic mirrors (OAPMs) are widely used in the THz and mm-wave communities for spectroscopy and imaging applications, as a result of their broadband, low-loss operation and high numerical apertures. However, the aspherical shape of an OAPM creates significant geometric aberrations: these make achieving diffraction-limited performance a challenge, and lower the peak electric field strength in the focal plane. Here, we quantify the impact of geometric aberrations on the performance of the most widely used spectrometer designs, by using ray tracing and physical optics calculations to investigate whether diffraction-limited performance can be achieved in both the sample and the detector plane. We identify simple rules, based on marginal ray propagation, that allow spectrometers to be designed that are more robust to misalignment errors, and which have minimal aberrations for THz beams. For a given source, this allows the design of optical paths that give the smallest THz beam focal spot, with the highest THz electric field strength possible. This is desirable for improved THz imaging, for better signal-to-noise ratios in linear THz spectroscopy and optical-pump THz-probe spectroscopy, and to achieve higher electric field strengths in non-linear THz spectroscopy.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s10762-023-00949-8

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Y.-S. Lee. Principles of terahertz science and technology, volume 170. Springer Science & Business Media, 2009.

Cited by

Sorted by citations

Authors
Chopra, N., & Lloyd-Hughes, J.
Affiliations
University of Warwick (GB)
Venue
Journal of Infrared, Millimeter, and Terahertz Waves
Published
2023-11-21
Volume
44
Issue
11-12
Pages
981-997
ISSN
  • 1866-6892 (ISSN-L)
  • 1866-6906
OpenAlex
W4388865587
Cited by
21
References
22
Citations by year
2026: 5 · 2025: 10 · 2024: 6
FWCI
1.56
Type
journal article
Language
en
Open access
Locations
  • Journal of Infrared Millimeter and Terahertz Waves (publishedVersion, cc-by)
  • arXiv (Cornell University) (submittedVersion, cc-by)
  • Figshare (submittedVersion, cc-by)
  • arXiv (Cornell University) (cc-by)
Funders
Engineering and Physical Sciences Research Council (EP/V047914/1)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced optical system design
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
Keywords
off-axis parabolic mirror, terahertz spectroscopy, terahertz imaging, diffraction-limited performance, geometric aberrations, aspheric mirrors, misalignment robustness, focal spot size, electric field strength, spectrometer design, optical pump-THz probe spectroscopy, ray tracing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review