Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index; 5 of the 16 sources its claims cite were checked for support.

Impact of Sub-picosecond Timing Errors on Complex Conductivity Extraction in Terahertz Time-Domain Spectroscopy of Ultrathin FAPbI3 Films

Open access
Cha, Minhee, Ryeom, Junho, Kang, Bong Joo, Park, Hajung, Jang, Hyunbin, Hong, Sung Ju, Bahk, Young-Mi · 2026 · Journal of Infrared, Millimeter and Terahertz Waves

Published version of a preprint

Abstract

Investigates the propagation and impact of sub-picosecond timing-delay errors on complex conductivity extraction in terahertz time-domain spectroscopy (THz-TDS) of ultrathin perovskite (FAPbI3) thin films, demonstrating that uncorrected sub-ps phase offsets produce substantial artifacts in extracted real and imaginary sheet conductivities.

Overview

CoChat Summary

TL;DR

Sub-picosecond timing offsets between sample and reference THz waveforms introduce frequency-dependent phase errors that mainly distort the imaginary conductivity and background permittivity of ultrathin FAPbI3 films. A phase-correction procedure restores physically plausible dielectric constants while leaving phonon resonance parameters largely unchanged.

Key findings

  • In 400-nm-thick FAPbI3 films, temporal offsets of ±0.02 ps (the sampling interval) produced negligible amplitude changes but pronounced frequency-dependent phase deviations; a +0.02 ps offset distorted the high-frequency response and gave unphysical negative conductivity above 2 THz, so that dataset was excluded from Lorentz fitting.
  • Lorentz oscillator fits identified two phonon resonances near 0.9 THz and 1.7 THz. Resonance parameters varied only slightly with timing correction: for +0.00 vs +0.02 ps, j=1 gave ω0 0.89→0.90 THz, ωp 0.37→0.34 THz, γ 0.25→0.22 THz; j=2 gave ω0 1.67→1.72 THz, ωp 0.65→0.69 THz, γ 0.52→0.60 THz.
  • Background permittivity was highly sensitive: the uncorrected +0.00 ps dataset yielded ε_DC = -13.4 and ε_∞ = -13.7, whereas the +0.02 ps corrected dataset yielded ε_DC = 32.8 and ε_∞ = 32.5, consistent with literature reports.
  • Substrate thickness mismatch also caused timing shifts: Sample 2 was delayed by approximately 0.06 ps relative to the reference, attributed to a thicker substrate.

Methods

  • Transmission-mode THz-TDS used a Ti:sapphire laser (94 fs pulses, 84 MHz, 800 nm, 10 nm bandwidth, 1 W average power), a photoconductive antenna on low-temperature-grown GaAs, and electro-optic sampling in a 1-mm-thick ZnTe crystal; the reference was a bare 1-mm-thick z-cut quartz substrate, and the sample was a 400-nm-thick FAPbI3 film spin-coated on quartz.
  • Time-domain waveforms were Fourier transformed to obtain transmission amplitude and phase; optical constants were extracted using a transfer-function/multilayer formalism, and complex conductivity was derived from the dielectric function.
  • A two-oscillator Lorentz model was fitted simultaneously to the dielectric function and conductivity spectra; controlled temporal offsets (±0.02 ps) and timing corrections (+0.00, +0.01, +0.02, +0.03 ps) were applied to the measured waveform of Sample 1.

Limitations

  • The paper does not include an explicit limitations section.
  • Evident from the text: the study is limited to one 400-nm-thick FAPbI3 film on 1-mm z-cut quartz and one THz-TDS setup; no variation of film thickness, substrate, or material is reported.
  • Evident from the text: the +0.02 ps offset dataset was excluded from Lorentz fitting because it produced unphysical negative conductivity above 2 THz, and the phase-correction procedure is demonstrated without broader validation across samples or conditions.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1007/s10762-026-01162-z

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

2 Valid · 1 Not valid · 6 Not checked · 42 Own results and interpretations

22 more claims

Create a free account to see all 51 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 21
  • Probably not a substantial claim. 5

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 50 references

Research works printed but not linked: 1

  1. G. Hecht, Optics, 5th ed. (Pearson, Boston, 2017).

Metadata

Authors
Cha, M., Ryeom, J., Kang, B. J., Park, H., Jang, H., Hong, S. J., & Bahk, Y.-M.
Affiliations
  • Incheon National University (KR)
  • Chung-Ang University (KR)
  • Korea Research Institute of Chemical Technology (KR)
  • Kangwon National University (KR)
Corresponding author
Bahk, Young-Mi
Venue
Journal of Infrared, Millimeter and Terahertz Waves
Published
2026-07-29
Volume
47
Issue
8
ISSN
  • 1866-6892 (ISSN-L)
  • 1866-6906
OpenAlex
W7171691797
Cited by
0
References
50
FWCI
0.00
Type
journal article
Language
en
Open access
Licence
Locations
  • Journal of Infrared Millimeter and Terahertz Waves (publishedVersion)
  • Research Square (submittedVersion, cc-by)
Funders
Incheon National University
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
Keywords
phase error, terahertz time-domain spectroscopy, ultrathin films, FAPbI3, perovskite thin films, Lorentz model, phase correction, dielectric constant, temporal offset

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-12, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-12 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of Sub-picosecond Timing Errors on Complex Conductivity Extraction in Terahertz Time-Domain Spectroscopy of Ultrathin FAPbI3 Films. https://app.cochat.ai/papers/10.1007/s10762-026-01162-z
The paper
Cha, M., Ryeom, J., Kang, B. J., Park, H., Jang, H., Hong, S. J., & Bahk, Y.-M. (2026). Impact of Sub-picosecond Timing Errors on Complex Conductivity Extraction in Terahertz Time-Domain Spectroscopy of Ultrathin FAPbI3 Films. Journal of Infrared, Millimeter and Terahertz Waves. https://doi.org/10.1007/s10762-026-01162-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.