Automated region mask for four-chamber fetal heart biometry
Abstract
This letter proposes an automated region mask for the detection of cardiac chambers from ultrasonic fetal heart biometry. The fetal biometry consists of two dimensional ultrasonic cine-loop sequences of apical four chamber view of fetal heart, which are comparatively The clinical motion information of individual frame is extracted by keeping a constant frame rate of 25 frames per second (fps). The region mask is designed based on the superimposition of motion information from a set of consecutive frames that belong to one cardiac cycle followed by connected component labelling. The borders and edges of all four chambers are thus recognized leading to formation of binary region mask. Experimental study based on second trimester cine-loop sequences confirms the suitability of the proposed technique for detection of heart chambers.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Detection of the fetal heart as a ROI in US images can be performed by AI models.
“the detection of the fetal heart as a ROI in US images can be performed by AI models [72,73].”
Cites
Achiron, R., Glaser, J., Gelernter, I., Hegesh, J. T., & Yagel, S. (1992) · BMJ · doi:10.1136/bmj.304.6828.671 · Cited by 263 · see citing works
Hierarchical image analysis using irregular tessellations
Montanvert, A., Meer, P., & Rosenfield, A. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.88566 · Cited by 170 · see citing works
Fetal echocardiography in three and four dimensions
Deng, J., Gardener, J. E., Rodeck, C. H., & Lees, W. R. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00119-6 · Cited by 101 · see citing works
New fetal cardiac imaging techniques
Deng, J., & Rodeck, C. H. (2004) · Prenatal Diagnosis · doi:10.1002/pd.1066 · Cited by 48 · see citing works
Deng, J. (2003) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.890 · Cited by 42 · see citing works
Improved segmentation of ultrasound images for fetal biometry, using morphological operators
Shrimali, V., Anand, R. S., & Kumar, V. (2009) · doi:10.1109/iembs.2009.5334470 · Cited by 39 · see citing works
Techniques for assessing cardiac output and fetal cardiac function
Tutschek, B., & Schmidt, K. G. (2010) · Seminars in Fetal and Neonatal Medicine · doi:10.1016/j.siny.2010.09.005 · Cited by 27 · see citing works
Comparison of septal defects in 2D and 3D echocardiography using active contour models
Lassige, T. A., Benkeser, P. J., Fyfe, D. A., et al. (2000) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(00)00032-x · Cited by 22 · see citing works
Echocardiographic Image Sequence Segmentation and Analysis Using Self-Organizing Maps
de Siqueira, M. L., Scharcanski, J., & Navaux, P. O. A. (2002) · The Journal of VLSI Signal Processing Systems for Signal Image and Video Technology · doi:10.1023/a:1016375620596 · Cited by 21 · see citing works
Deng, Y., Wang, Y., Shen, Y., et al. (2011) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2011.04.002 · Cited by 17 · see citing works
Cardiac Structure Recognition in Ultrasound Images
de Siqueira, M. L., Müller, D., & Navaux, P. O. A. (2007) · International Conference on Systems, Signals and Image Processing · doi:10.1109/iwssip.2007.4381141 · Cited by 10 · see citing works
Wavelet segmentation for fetal ultrasound images
Zayed, N. M., Badwi, A. M., Elsayad, A. M., et al. (2002) · doi:10.1109/mwscas.2001.986220 · Cited by 10 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Segmentation and classification in MRI and US fetal imaging: Recent trends and future prospects
Torrents-Barrena, J., Piella, G., Masoller, N., Gratacós, E., Eixarch, E., Ceresa, M., & Ballester, M. Á. G. (2019) · Medical Image Analysis · doi:10.1016/j.media.2018.10.003 · Cited by 97 · see citing works
Jost, E., Kosian, P., Jimenez Cruz, J., Albarqouni, S., Gembruch, U., Strizek, B., & Recker, F. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12216833 · Cited by 44 · see citing works
“As a solution to this issue and an emerging research focus, the detection of the fetal heart as a ROI in US images can be performed by AI models [72,73].”
BackgroundSriraam, N., Punyaprabha, V., Sushma, T. V., & Suresh, S. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02814-1 · Cited by 5 · see citing works
- Authors
- Vijayalakshmi, S., Sriraam, N., Suresh, S., & Muttan, S.
- Affiliations
- Anna University, Chennai (IN)
- Sri Sivasubramaniya Nadar College of Engineering (IN)
- Corresponding author
- Sriraam, N.
- ORCID
- Sriraam, N.
- Venue
- Journal of Clinical Monitoring and Computing
- Published
- 2012-10-21
- Volume
- 27
- Issue
- 2
- Pages
- 205-209
- ISSN
- 1387-1307 (ISSN-L)
- 1573-2614
- OpenAlex
- W2034252414
- Cited by
- 15
- References
- 12
- Citations by year
- 2024: 2 · 2023: 3 · 2022: 3 · 2021: 1 · 2019: 3 · 2018: 1 · 2016: 1 · 2012: 1
- FWCI
- 0.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Clinical Monitoring and Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- apical four-chamber view, motion information, connected component labeling, binary segmentation, second trimester, fetal echocardiography
- MeSH terms
- Algorithms, Automation, Biometry, Female, Fetal Heart, Gestational Age, Humans, Image Processing, Computer-Assisted, Pregnancy, Pregnancy Trimester, Second, Ultrasonography, Prenatal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review