The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Detection of changes in muscle oxygen saturation in the human leg: a comparison of two near-infrared spectroscopy devices
Abstract
The purpose of this study was first to evaluate the near infrared spectroscopy (NIRS) device, INVOS 4100 as a method of measuring exercise and arterial occlusion induced muscle ischemia in human leg, by comparison with InSpectra tissue spectrometer Model 325, and secondly to determine the influence of skin and subcutaneous thickness on the NIRS measurements. Twenty healthy subjects (43 ± 8 years) volunteered for the study. Tissue oxygen saturation (StO2) in the anterior tibial muscle was measured simultaneously with InSpectra Model 325 in one leg and INVOS 4100 in the contralateral leg during an exercise test until muscle exhaustion and arterial occlusion with and without exercise. The skin and subcutaneous thickness was identified by ultrasound imaging. Baseline StO2 was 87 ± 8 % detected by InSpectra and 76 ± 6 % by INVOS. Both devices detected an immediate decrease of StO2 (p < 0.001) during exercise, arterial occlusion with and without exercise, and a significant post ischemic hyperaemia (p < 0.001) during recovery. There was a significant inverse correlation between skin and subcutaneous thickness and baseline StO2 (r = -0.78, p < 0.01) as well as change in StO2 during exercise (r = -0.65, p = 0.002) for InSpectra, which was not apparent for INVOS. The results demonstrate that the cerebral/somatic oxygenation monitor (INVOS) is able to detect experimentally induced skeletal muscle ischemia in the human leg as well as the peripheral tissue spectrometer (InSpectra). Muscle…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Past studies comparing NIRS monitors have highlighted discrepancies in the values obtained at rest and during exercise in human 11 -14 and animal 15 systems.”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [14]
Citations
Cites
A temporal comparison of BOLD, ASL, and NIRS hemodynamic responses to motor stimuli in adult humans
Huppert, T. J., Hoge, R. D., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.065 · Cited by 846
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Scheeren, T. W. L., Schober, P., & Schwarte, L. A. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9348-y · Cited by 478
Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
Naturally occurring muscle pain during exercise: assessment and experimental evidence
COOK, D. B., O'CONNOR, P. J., EUBANKS, S. A., SMITH, J. C., & LEE, M. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199708000-00004 · Cited by 310
Agreed Statistics: Measurement Method Comparison
Bland, J. M., Altman, D. G., & Warner, D. S. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31823d7784 · Cited by 252
Myers, D. E., Anderson, L. D., Seifert, R. P., Ortner, J. P., Cooper, C. E., Beilman, G. J., & Mowlem, J. D. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1925250 · Cited by 189
Diagnostic Techniques in Acute Compartment Syndrome of the Leg
Shadgan, B., Menon, M. R., O'Brien, P. J., & Reid, W. D. (2008) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e318183136d · Cited by 188
Intramuscular pressure and muscle blood flow during exercise in chronic compartment syndrome
Styf, J., Körner, L. K., & Suurkula, M. (1987) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.69b2.3818765 · Cited by 121
Hagenouw, R. R. P. M., Bridenbaugh, P. O., van Egmond, J., & Stuebing, R. C. (1986) · Anesthesia & Analgesia · doi:10.1213/00000539-198611000-00013 · Cited by 114
Cited by
McManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 175
Lee, J.-H., Park, Y.-H., Kim, H.-S., & Kim, J.-T. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-014-9595-1 · Cited by 20
Metadata
- Authors
- Nygren, A., Rennerfelt, K., & Zhang, Q.
- Affiliations
- Sahlgrenska University Hospital (SE)
- Corresponding author
- Nygren, Andreas
- Venue
- Journal of Clinical Monitoring and Computing
- Published
- 2013-07-12
- Volume
- 28
- Issue
- 1
- Pages
- 57-62
- ISSN
- 1387-1307 (ISSN-L)
- 1573-2614
- OpenAlex
- W2071134130
- Cited by
- 33
- References
- 23
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 3 · 2023: 2 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 5 · 2018: 2 · 2017: 2 · 2016: 6 · 2015: 2 · 2014: 3
- FWCI
- 2.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Clinical Monitoring and Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Keywords
- near-infrared spectroscopy, muscle oxygen saturation, skeletal muscle ischemia, arterial occlusion, physical activity, tibial muscle, skin thickness, device comparison
- MeSH terms
- Adult, Arteries, Blood Pressure, Exercise Test, Female, Humans, Ischemia, Leg, Male, Middle Aged, Muscles, Oximetry, Oxygen, Oxygen Consumption, Skin, Cohort Studies, Exercise, Body Mass Index, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.